Step 4: Set Up Data Cable Connections
The VTrak J300s unit provides Direct Attached Storage (DAS) support to the
Host PC.
Figure 6. VTrak J300s has one or two I/O modules
There can be one or two Input Output Modules (I/O modules) on the J300s unit.
•
If your J300s has two I/O modules, I/O module 1 (on the left) is the default
primary.
•
If your J300s has only one I/O module, that I/O module is the default primary.
Under SAS specifications, both I/O modules are active the same time. The terms
primary
and
secondary
are for enclosure management purposes only. To verify
which I/O module is the default primary, see Chapter 3 of the
VTrak J300s
Product Manual
.
Figure 7. VTrak J300s I/O modules have two host ports and one expansion
port
Important
Be sure each drive is securely fastened to its carrier. Proper
installation ensures adequate grounding and minimizes vibration.
Do not install drives with fewer than four screws.