Universal control wire connection diagram
Universal control wire connection diagram
Site end
Site end
Cable
Cable
Pump, inside
Pump, inside
2 white / Contact
4 brown / GND
GND
External
activation
Function "External Contact"
(ProMinent external/contact cable)
2-core
1 brown / Pause
2 white / Contact
4 black / GND
3 blue / Analog
5 grey /Auxiliary
GND
GND
External
activation
1 brown / Pause
2 white / Contact
4 black / GND
3 blue / Analog
5 grey /Auxiliary
External
activation
1 brown / Pause
2 white / Contact
4 black / GND
3 blue / Analog
5 grey /Auxiliary
External
activation
1 brown / Pause
2 white / Contact
4 black / GND
3 blue / Analog
5 grey /Auxiliary
External
activation
GND
GND
+
-
Function "External Contact"
(ProMinent universal control wire)
5-core
"Pause" function
"Auxiliary rate" function
Function "External Contact"
Pulse frequency,
e.g. contact water meter, PLC etc.
Pulse frequency,
e.g. contact water meter, PLC etc.
Continuous contact (potential-free)
E.g. external on/off of control panel
Continuous contact (potential-free)
e.g. of control panel
0/4-20 mA
Analog signal,
e.g. of magnetic inductive
Flow meter
P_SI_0091_SW
7.2.2 HMI operating unit
The HMI must be connected to the CAN socket above the LEDs of the
pump base if the pump is operated via the HMI.
Installation
39
Содержание S3Cb
Страница 102: ...Spare part Type 120145 120190 120270 Valve 803708 Multi layer diaphragm 1029604 Liquid ends for Sigma 3 102 ...
Страница 107: ...PTFE FDA No 21 CFR 177 1550 PVDF FDA No 21 CFR 177 2510 Wear parts for S3Cb 107 ...
Страница 121: ...121 ...
Страница 122: ...122 ...
Страница 123: ...123 ...