Page 40
Maintenance / Technical Data
Function and Fault Indicators on Ballast Units
The three red LEDs on the ballasts serve the purpose of checking function and troubleshooting.
All three LEDs light up for approx. 1 second when the supply voltage is applied.
LED “Power Supply” (identification on pc-board “Power”)
ON
Ballast power supply is OK
OFF
Although the master switch is on and the power plug is connected
➤
Check power supply (only by authorised electrician!)
➤
Check fine fuse
LED “Lamp” (identification on pc-board “Error”)
Flashes for
approx. 1 to 15 sec
Lamp electrodes are preheated before ignition
ON
UV lamp inoperative
The LED goes out by switching the power supply off and on again and comes on again after a
renewed ignition attempt
➤
Check lamps
LED “Bus” (identification on pc-board “Tx”)
Lights up every 0.1 to 3 sec
The ballast is addressed by the control.
Does not light up
Although the system is switched on:
The bus connection to the ballast is interrupted or the ballast is defective
IMPORTANT!
Since the data bus is designed as a bus with ring structure, the ballasts following a
defective ballast or interrupted data line can no longer be addressed.
8
Technical Data
ATTENTION!
These technical data supplement the supplied datasheet!
In the case of doubt, the data specified on the datasheet shall apply!
8.1
Performance Data
Type
Number
Lamp
Connected
Minimum
Empty weight /
Max.
Nominal
of lamps
output
load
clearance for
operating weight
flow rate
connection
(kW)
(kW)
lamp change
of radiation
(98 %/cm
diameter
(mm)
chamber
transm.,
(kg)
400 J/m
2
)
(m
3
/h)
1*300R
1
0.3
0.32
3000
45 / 67
30
DN 80
2*300R
2
0.6
0.65
3070
75 / 134
95
DN 150
3*300R
3
0.9
1.0
3075
90 / 182
179
DN 200
4*300R
4
1.2
1.3
3089
120 / 253
274
DN 250
Permissible operating temperatures:
• Water temperature:
5 ... 40
°
C
• Ambient temperature:
5 ... 40
°
C
Requirements relating to water to be treated:
• Maximum temperature: 40
°
C
• Maximum operating pressure: 10 bar*)
• No corrosive or abrasive properties, chloride level < 250 ppm
• No propensity to precipitation
ATTENTION! *)
The maximum permissible operating pressure may be lower in special-application systems!