![promethean PRM-20 Скачать руководство пользователя страница 7](http://html.mh-extra.com/html/promethean/prm-20/prm-20_service-manual_1616762007.webp)
-7-
Maintenance
Air filter care and cleaning
Air filters prevent dust from accumulating on the optical elements inside the projector. Should the air filters become
clogged with dust particles, it will reduce cooling fans’ effectiveness and may result in internal heat build up and
adversely affect the life of the projector. Clean the air filters following the steps below.
Air filters
Pull up and remove.
recoMMeNdAtIoN:
We recommend avoiding dusty/smoky environments
when operating the projector. Usage in these
environments may cause poor image quality.
When using the projector under dusty or smoky conditions, dust may accumulate on a lens, LCD panels, or optical
elements inside the projector. This condition may degrade the quality of a projected image.
When the symptoms above are noticed, contact your authorized dealer or service station for proper cleaning.
cAutIoN:
Do not operate the projector with the air filters removed.
Dust may accumulate on the LCD panel and the projection
mirror degrading picture quality.
Do not put small parts into the air intake vents. It may result
in malfunction of the projector.
1. Turn off the projector, and disconnect the AC power cord
from the AC outlet.
. Turn over the projector and remove the air filters by pulling
the latches upward.
. Clean the air filters with a brush or rinse them softly.
4. When cleaning the air filters by rinsing, dry them well.
Replace the air filters properly. Make sure that the air fil-
ters are fully inserted.
Be sure to reset the Filter counter after cleaning or replacing the filters.
Press the MENU button to display the On-Screen
Menu. Use the Point
7 8
buttons to move the red
frame pointer to the Setting Menu icon.
Use the Point
ed
buttons to move the red frame
pointer to Filter counter and then press the SELECT
button. A dialog box appears showing the total
accumulated time of the filter use, a timer setting
option, and the reset option. Select Reset and the
“Filter counter Reset?” appears. Select [Yes] to
continue.
1
2
resetting the Filter counter
Filter counter
Another confirmation dialog box appears, select [Yes]
to reset the Filter counter.
3
Select Reset and
the “Filter counter
Reset?” appears.
Select [Yes],
then another
confirmation
box appears.
Select [Yes] again
to reset the Filter
counter.
Содержание PRM-20
Страница 67: ... 67 IC Block Diagrams FA7703 DDC Control IC7811 TC74LVX4053 Analog Multiplexer Demultipexer IC1041 ...
Страница 68: ... 68 IC Block Diagrams MP2106 DC DC Converter IC5821 IC5861 FA5502 P F Control IC621 ...
Страница 69: ... 69 IC Block Diagrams L3E06150 D A S H LCD Driver IC501 IC531 IC561 HIN202EIB RS 232C Driver IC3801 ...
Страница 70: ... 70 IC Block Diagrams L3E01060 Level Shift IC2501 IC2531 IC2561 L3E07111 LCD Driver Gamma Correction IC401 ...
Страница 71: ... 71 IC Block Diagrams LM4889 Audio Output IC5031 NJW1156 Audio Control IC5001 ...
Страница 72: ... 72 IC Block Diagrams PW190 System Control ADC Video Decoder Scaler IC301 STR Z2156 Power OSC IC631 ...
Страница 73: ... 73 TE7783 Parallel I O Expander IC1802 IC Block Diagrams R5F21134FP System Control Alarm IC8701 ...
Страница 74: ... 74 LAN9118 LAN Driver IC8801 IC Block Diagrams MC9328MX21 System Control of Network IC8301 ...
Страница 100: ...KM5 2000 KM5 20 S 00 100 Mechanical Parts List L12 L08 L13 L14 L05 L15 L11 L09 L04 L06 In the Optical Unit L08 ...
Страница 103: ...KM5 2000 KM5 20 S 00 103 ...
Страница 104: ... KM5YC KM5ZC January 2009 DC 200 Printed in Japan ...
Страница 116: ...A10 SCH_KM5YC SCH_KM5ZC NO DATA ...