 11.D. Certificate of Decontamination

Disinfection and decontamination are required before shipping the instrument and instrument accessories for repair. 
Instruments returned for service must be accompanied by a signed and dated Certificate of Decontamination, which 
must be attached to the outside packaging of the instrument.

1. 

Clean the optical head according to the instructions in Section 11.A.

Failure to confirm disinfection and decontamination will result in decontamination charges before the 
instrument will be serviced.

Select either (A) or (B):

A. 

I confirm that the returned items have not been contaminated by body fluids or by toxic, carcinogenic, radioac-
tive, or other hazardous materials.

B. 

I confirm that the returned items have been decontaminated and can be handled without exposing personnel to 
health hazards.

Circle the type of material used in the instrument: 

 

Chemical  

Biological 

Radioactive**

Briefly describe the decontamination procedure performed:

             
             
             
Date:  

            

Place:  

            

Signature:  

           

Name (block capital letters):  

        

** The signature of a Radiation Safety Officer is also required if the instrument was used with radioactive materials.

This instrument is certified by the undersigned to be free of radioactive contamination.

Date:  

            

Place:  

            

Signature:  

           

Name (block capital letters):  

        

Содержание E5311

Страница 1: ...Revised 5 21 TM276 T E C H N I C A L M A N U A L GloMax 20 20 Luminometer Instructions for Use of Products E5311 E5351 and E5361...

Страница 2: ...ct Components 4 3 Hardware Overview 4 4 Setting up the GloMax 20 20 Luminometer 5 4 A Setup 5 4 B Software Installation and System Connection 5 5 Operating the GloMax 20 20 Luminometer 6 5 A Touch Scr...

Страница 3: ...USA 800 356 9526 608 274 4330 Fax 608 277 2516 TM276 Revised 5 21 www promega com 10 Troubleshooting 14 11 Appendix 15 11 A General Care 15 11 B Warranty and Service 15 11 C Specifications 16 11 D Ce...

Страница 4: ...horseradish peroxidase and alkaline phosphatase The touch screen on the luminometer allows easy setup and operation The GloMax 20 20 Luminometer also features optional modules for measuring certain fl...

Страница 5: ...311 Includes 1 Luminometer 1 1 5ml Microcentrifuge Tube Holder 1 USB Cable 1 Power Supply Kit 1 Quick Start Guide FB081 Items Available Separately P R O D U C T S I Z E C AT GloMax 20 20 Fluorescent M...

Страница 6: ...GloMax Spreadsheet Interface Software is compatible with 32 and 64 bit PCs using Windows 7 Professional Service Pack 1 with either Microsoft Office 2010 Home and Business Edition 32 and 64 bit versio...

Страница 7: ...a function touch the button corresponding to the function once 5 B Home Screen The Home Screen Figure 3 provides orientation for the multiple functions of the GloMax 20 20 Luminometer From the Home S...

Страница 8: ...surement settings automatically programmed Touch OK to accept the parameters and return to the Home Screen You are now ready to measure your samples 5389TA Figure 4 The Protocol Menu 5 E Creating a Ne...

Страница 9: ...tocol To access a saved protocol select Run User Protocol The next screen will display protocols previously saved on the luminometer Identify and touch the name of your protocol The next screen will d...

Страница 10: ...roll through recent measurements Note Measurements are not saved after power down The instrument display will only show 20 measurements additional measurements will overwrite the first measurements Fo...

Страница 11: ...nu Although the touch screen is calibrated at the factory it may need recalibration during instrument setup and over time Contact Promega for more information on screen calibration If the touch screen...

Страница 12: ...e Identification Screen will appear Identify the Light Standard The luminometer will automatically power OFF The GloMax 20 20 Luminometer will automatically identify the Light Standard for subsequent...

Страница 13: ...ule is designed for easy installation and removal Store the Fluorescent Module in the product case when not in use Keep liquids dust and debris away from direct contact with the Fluorescent Module 9 A...

Страница 14: ...ppb ppt or FSU With a valid calibration it is not necessary to generate a standard curve to determine the actual concentration of the sample Calibration Touch Calibration to calibrate the Fluorescent...

Страница 15: ...reen until the Home Screen appears Also see Section 8 B Touch Screen Calibration Excel does not open Excel is not installed on the PC Make sure Microsoft Excel is installed on your PC and activated Th...

Страница 16: ...11 B Warranty and Service The GloMax 20 20 Luminometer comes with a one year warranty from Promega Additional warranty is available For more information contact Promega Technical Services Contact info...

Страница 17: ...ft Office 2007 32 bit version Power 0 5A 100 240V 50 60Hz universal Dimensions 12 92 D 10 44 W 8 42 H 32 82 26 52 21 39cm Weight 8 1 lb 3 65kg Warranty One year CE Compliance Pollution degree 2 Instal...

Страница 18: ...on will result in decontamination charges before the instrument will be serviced Select either A or B A I confirm that the returned items have not been contaminated by body fluids or by toxic carcinog...

Страница 19: ...20 Replacement Power Supply 1 each E5411 Thermal Serial Printer and Cable Universal Power 1 each E2821 Tripp Lite USB to Serial Adapter 1 each TS2520 Microplate Readers Product Size Cat GloMax Discove...

Страница 20: ...rporation Microsoft and Windows are registered trademarks of Microsoft Corporation PicoGreen and RiboGreen are registered trademarks of Molecular Probes Inc Products may be covered by pending or issue...

Отзывы: