background image

Содержание ProM-500

Страница 1: ...ProM 500 EMS Electrical Muscle Stimulator INSTRUCTION MANUAL ...

Страница 2: ...Attachment of Electrode Lead Wires 9 13 Lead Wire Maintenance 9 14 Electrode Options 10 15 Electrode Placement 10 16 Tips For Skin Care 10 17 Application of Re usable Self Adhesive Electrodes 11 18 Adjusting The Controls 12 19 Battery Information 15 20 Maintenance Transportation and Storage of EMS Device 17 21 Safety technical Controls 18 22 Malfunctions 18 23 Conformity to Safety Standards 19 24 ...

Страница 3: ...cle relaxes and the cycle starts over again Stimulation Contraction and Relaxation Powered muscle stimulators should only be used under medical supervision for adjunctive therapy for the treatment of medical diseases and conditions Chapter 2 CAUTIONS 1 Safety of powered muscle stimulators for use during pregnancy has not been established 2 Caution should be used for patients with suspected or diag...

Страница 4: ...dren Chapter 4 CONTRAINDICATION Powered muscle stimulators should not be used on patients with cardiac demand pacemakers Chapter 5 ADVERSE REACTIONS Skin irritation and burns beneath the electrodes have been reported with the use of powered muscle stimulators o Chapter 6 GENERAL DESCRIPTION The ProM 500 is a battery operated pulse generator that sends electrical impulses through electrodes to the ...

Страница 5: ...electable 100us 200us 300ns Adjustable 1 30 seconds Adjustable 1 45 seconds Adjustable 1 8 seconds S Synchronous C Constant A Alternate Constant stimulation based on setting value Stimulation of both channels occurs synchronously The stimulation of the CH2 will occur after the 1st contraction of CH1 is completed Temperature 0 40 C Relative Humidity 30 75 Atmosphere Pressure 700Hpa 1060Hpa There ma...

Страница 6: ...l Protection BF 3 W Do not insert the plug into AC power supply socket 4 Direct Current DC power source Chapter 12 ATTACHMENT OF ELECTRODE LEAD WIRES The wires provided with the system insert into the jack sockets located on top of the device Holding the insulated portion of the connector push the plug end of the wire into one of the jacks see drawing one or two sets of wires may be used V J LEADW...

Страница 7: ...placing the electrodes using mild soap and water before applying electrodes and after taking them off Be sure to rinse soap off thoroughly and dry skin well 2 Excess hair may be clipped with scissors do not shave stimulation area 3 Wipe the area with the skin preparation your clinician has recommended Let this dry Apply electrodes as directed 4 Many skin problems arise from the pulling stress from...

Страница 8: ... are in the off position white markings on the housing the device is switchedoff By turning the controls clockwise the appropriate channel is switched on and the impulse display led will illuminate and begin to pulse according to the frequencyset The current strength of the impulses transmitted to the electrodes increases further when the control is turned clockwise To reduce the current strength ...

Страница 9: ...l When the ramp time is set each contraction may be ramped in order that signals come on gradually and smoothly The ramp time is adjustable from 1 to 8 seconds by turning this switch t L V i 10 Mode Control This dial controls the output mode of the unit There are three mode of options S Synchronous C Constant andA Alternate Push the dial to select a mode which is needed r 11 Check Replace the Batt...

Страница 10: ...it as soon as possible If the battery is stored more than 60 days it may need to be recharged c Do not short the terminals of the battery This will cause the battery to get hot and can cause permanent damage Avoid storing the batteries in your pocket or purse where the terminals may accidentally come into contact with coins keys or any metal objects d WARNINGS 1 Do not attempt to charge any other ...

Страница 11: ...l correctly whether the cable is correctly connected to the device The cables should be inserted completely into the sockets whether the impulse display led is illuminated If necessary insert a new battery for possible damage to the cable Change the cable if any damage is detected If there is any other problem please return the device to your distributor Do not try to repair a defective device Cha...

Отзывы: