USER’S MANUAL. PROMAX-10 

Premium

Page 40

05/2004

On the bottom of the display appears present time and date. To modify them

see section 4.2.1 Global Configuration Menu.

To accede to any of the different fields of the initial screen of the LOGGER function,

turn the rotary selector [9] until it is activated (it appears shadowed) and next press it.

First of all you must select the logger on which you want to perform any

function: turn the rotary selector until the LOGGER NUMBER field is shadowed and
press it. Then turning the rotary selector, select the desired logger (from 0 to 54) and
finally press it again to validate. The acquisition date appears under the logger number
(only if you have taken measurements on this logger).

To carry out a logger acquisition you must select the MEASURE function, for this

purpose turn the rotary selector [9] and when this field appears shadowed press it, in this
way you will accede to the logger. Next press again the rotary selector [9] in order that the
PROMAX-10 

Premium

 makes all the measurements defined in the LOGGER

configuration menu over all the active channels of the channel plan (see Edit Channel
Plan
 function at section 4.2.1 Global configuration menu).

IMPORTANT

The processing of channels as analogue or digital and the parameters to make
the measures (the frequency of the audio carrier for the analogue channels and
the frequency offset for the noise measure of the digital channels C/N ratio) will
correspond with the configuration of the equipment at the time of carrying out the
measurement.

To return to the initial menu of the LOGGER function press the LOGGER key.

To check the measurements stored in a specific logger select the VIEW option:

The first line shows the channel plan (CCIR in the

example), the audio carrier offset (5.50 MHz), the audio
demodulation (FM) and the units of measurement (dBµV).
The second line shows the logger number (53 in the
attached figure) and the headings of the measurements
(V,  V/A and C/N). The measurements taken are
shown in the following format: first column shows the
channel, the D indication on its right means it has been defined as digital (see Edit
Channel Plan
 function at section 4.2.1 Global configuration menu), the second column
shows the level (analogue channels) or the channel power (digital channels), the third
the V/A ratio (analogue channels) an the fourth the C/N ratio (analogue channels) or
MER (digital channels). Turning the rotary selector [9] you can see the rest of channels.

The time and date when measurements were taken appear at the end of the list

of measurements, in the following order: hour:minute:second and month:day:year. To
return to the initial menu of the LOGGER FUNCTION press LOGGER key.

To print the stored measurement select the PRINT field, previously consult

section 4.3 Connecting to a computer or a printer.

Figure 41.- Viewing a logger.

Содержание PROMAX-10 Premium

Страница 1: ...2 3 1 2 Audio carrier measurement and demodulation 25 4 2 3 1 3 CSO CTB distortion products measurement 25 4 2 3 1 4 Power and C N ratio measurement of digital channels DVB C DVB T DAB 27 4 2 3 1 5 C...

Страница 2: ...ier Noise ratio measurement C N Video Audio ratio measurement V A CSO and CTB Intermodulation distortion measurement Digital channels DVB C DVB T and DAB Channel power measurement by integration Carri...

Страница 3: ...ing to a printer or computer for producing reports on the measurements obtained The instrument is powered by means of an internal rechargeable battery All these functions have been brought together in...

Страница 4: ...R Modulation error ratio Measurement range 22 dB to 34 dB for 64 QAM Accuracy 2 dB BER Bit error rate Measured before RS decoding Measurement range 10 E 2 to 10 E 8 Constellation Diagram DVB QAM signa...

Страница 5: ...sured at four frequencies user definable Measuring frequencies User definable from 2 50 to 0 50 MHz and from 0 50 to 2 50 MHz Default values 1 50 0 50 0 50 and 1 50 MHz CTB Ratio of the peak level of...

Страница 6: ...dB Detection range From 5 to 100 MHz maximum Readout Number of detected transitory in the measuring time Present detected level and maximum detected level in the time of the measurement AUDIO Demodul...

Страница 7: ...present For higher input power levels the use of an external attenuator of 20 dB is recommended There may be certain frequencies where the symbol appears at levels higher than 25 dB V maximum 28 dB Th...

Страница 8: ...tute mains adapter by AL 052 OP 010 61 Change channel plan Carried out under request in the factory OP 010 E Extension of SYMBOL RATE measurement range OPTIONAL ACCESSORIES AD 055 F female BNC female...

Страница 9: ...nts It is for INDOOR USE When using some of the following accessories use only the specified ones to ensure safety Power adapter Car cigarette lighter adapter Observe all specified ratings both of sup...

Страница 10: ...ed with safety DIRECT CURRENT ALTERNATING CURRENT DIRECT AND ALTERNATING GROUND TERMINAL PROTECTIVE CONDUCTOR FRAME TERMINAL EQUIPOTENTIALITY ON Supply OFF Supply DOUBLE INSULATION Class II protection...

Страница 11: ...ium English 2 2 Descriptive Examples of Over Voltage Categories Cat I Low voltage installations isolated from the mains Cat II Portable domestic installations Cat III Fixed domestic installations Cat...

Страница 12: ...illuminated during this period On having finished the battery charge the indicator will be illuminated blinking to indicate that a maintenance charge takes place 2 With the instrument working when co...

Страница 13: ...nding on the time and temperature of inactivity the battery will have been reconditioned 3 2 Installation and start up The PROMAX 10 Premium has been designed for use as portable equipment A fully cha...

Страница 14: ...controls and elements Front panel Figure 2 Front panel 1 F F or F BNC or F IEC adapter Maximum input voltage level 60 VAC rms 50 60 Hz 2 F male base connector 3 Graphic display with back lighting 4 DC...

Страница 15: ...other than that supplied by the manufacturer otherwise the instrument may suffer serious damage 9 Rotary selector Push button Figure 3 PROMAX 10 Premium keyboard 10 Selects the CHANNEL FREQUENCY opera...

Страница 16: ...mode enables multiple measurements to be performed and memorised for subsequent checking transfer to PC or printing It can perform and store up to 55 obtained measurements or loggers in the memory Ea...

Страница 17: ...simply press the corresponding key The parameters relative to a particular operating mode can be modified through the configuration menu associated to the mode In order to accede to the configuration...

Страница 18: ...ing the rotary selector the unit accedes to the active CHANNEL PLAN The attached figure shows an example of channel plan The first line shows the name of the channel plan CCIR in the figure the audio...

Страница 19: ...s digital it is possible to accede directly to the digital channel configuration In order to return to the Edit Channel Plan function press the CONFIG 14 key To modify the rest of characteristics of t...

Страница 20: ...nu Turn the rotary selector until appears shaded line VLNB Press the rotary selector to activate the selection Turning the rotary selector this one goes successively of OFF to ON Finally to press the...

Страница 21: ...press the rotary selector 9 the span field is activated and then turn it The span is variable from the entire band full span to 10 MHz in the following steps 10 30 100 300 MHz y full span By pressing...

Страница 22: ...or this mode This menu permits to change three parameters THRESHOLD REFERENCE LINE and POWER MEASUREMENT To accede to any of them turn the rotary selector 9 until it appears shaded and next press the...

Страница 23: ...channel tuning to frequency tuning 4 2 3 1 Channel tuning 4 2 3 1 1 Video carrier V A C N measurement If the tuned channel has been defined as analogue by means of the Edit Channel Plan function see s...

Страница 24: ...ird order beats The CSO distortion Composite Second Order is defined as a ratio of the peak level of the video carrier to the peak of the distortion products of second order beat produced by the rest...

Страница 25: ...o make this measurement at one of the free adjacent channels see section 4 2 3 3 Channel Frequency mode configuration MEASURING METHOD When pressing the rotary selector 9 again we will accede to the C...

Страница 26: ...orrectly previously the channel must be defined as digital see Edit Channel Plan function at section 4 2 1 Unit Global Configuration and if necessary the CHANNEL BW parameter should be redefined by me...

Страница 27: ...Frequency configuration menu paragraph 4 2 3 3 allows the user to redefine this parameter when tuning a new channel the equipment will return to assign to NOISE FREQ the default value The following fi...

Страница 28: ...fication MPEG2 When pressing again the rotary selector the PROMAX 10 Premium carries out a new measurement If the selector rotary is pressed two times it is acceded again to the screen of Power and C...

Страница 29: ...4 2 3 2 Frequency tuning and configuration When in CHANNEL FREQUENCY operating mode pressing again the CH FR 10 key switches tuning by channel to tuning by frequency and vice versa In the tuning by f...

Страница 30: ...s when operating in frequency tuning are identical to the described ones for the channel tuning operation See section 4 2 3 1 Channel tuning b Configuration When the PROMAX 10 Premium works in the FRE...

Страница 31: ...measured in the C N measurement NOISE FREQ 99 9 MHz relative mode 5 00 MHz to 862 00 MHz absolute mode Only digital channels Noise measuring mode NOISE MODE FREQ Absolute Noise level is measured at th...

Страница 32: ...press The value of the parameter will be activated and may be changed by turning the rotary selector When the value you want appears press the rotary selector 9 to validate it DESCRIPTION PARAMETER VA...

Страница 33: ...or the channel tuning PROMAX 10 Premium admits values from 2 00 to 2 00 MHz IMPORTANT To leave the configuration menu of the CHANNEL FREQUENCY mode just press the key of the operating mode you wish to...

Страница 34: ...he rotary selector 9 a second time will activate the tuning frequency field of the marker being possible to tune new frequencies Figure 30 Reference level modification The attached figure shows an hor...

Страница 35: ...mode configuration menu In this operating mode it is advised to select the Average detector see section 4 2 4 5 Spectrum mode configuration menu Figure 33 MIN mode First scan Figure 34 After several...

Страница 36: ...g the rotary selector When the value you want appears press the rotary selector 9 to validate it The parameters that can be modified through this menu are a BAND It selects the analyzed band between R...

Страница 37: ...TS will appear Turning the rotary selector 9 the reference level may be modified The pilots may be defined in two ways a By frequency Using the TILT configuration menu See section 4 2 5 1 Tilt mode co...

Страница 38: ...of the TILT mode just press the key of the operating mode you wish to access 4 2 6 DATALOGGER operating mode The LOGGER function permits to automatically measure the level the Carrier Noise ratio and...

Страница 39: ...dio carrier for the analogue channels and the frequency offset for the noise measure of the digital channels C N ratio will correspond with the configuration of the equipment at the time of carrying o...

Страница 40: ...HRESHOLD and MEASURES parameters To accede to them turn the rotary selector and once the parameter we want to change is appears shadowed press it then turning it its value will be modified Finally pre...

Страница 41: ...odel CC 208 Do not connect any cable other than that supplied by the manufacturer otherwise serious damage may be caused to the equipment 1 Prior to connecting the equipment to a PC disconnect both fr...

Страница 42: ...from a computer the following options 1 CHANNELS PLAN PROCESSOR Modify add or delete channel plans 2 CONFIGURATION Permits to modify all the configuration parameters 3 DATALOGGER Permits to edit and...

Страница 43: ...sed agents or by personnel qualified in the servicing of instruments 5 2 1 Cleaning the cover CAUTION Do not use scented hydrocarbons or chlorized solvents Such products may attack the plastics used i...

Страница 44: ...es are In the transmission line From 70 to 100 dB V From 10 to 40 dBmV In the user s terminal From 60 to 80 dB V From 0 to 20 dBmV B Positive Video Modulation SECAM On this type of modulation the line...

Страница 45: ...EL ANALOGUE CHANNELS The user can obtain the ratio between the video carrier amplitudes of two adjacent channels dB C C 2 LV 1 LV Figure 45 Measurement of the adjacent channel level Differences of mor...

Страница 46: ...the video carrier and the audio carrier amplitudes Although this process depends on the standard used it is usual to consider that a properly transmitted PAL channel should have a sound subcarrier 13...

Страница 47: ...BW N C N C where C Video carrier level NBWX Noise power referred to a BWx measurement bandwidth and as the noise power referred to BWx could be related with the noise power referred to 5 MHz according...

Страница 48: ...ge Example Suppose that the video carrier level for an analogue channel is of 10 dBmV from the diagram we can deduce that the measurement range is of 48 dB Thus if when we carry out the measurement th...

Страница 49: ...Error Rate The DBV Group Digital Video Broadcasting defines a quasi error free transmission ETR290 Measurements Group ETR 290 as that with less than 1 error event per transmission hour For a 64 QAM DB...

Страница 50: ...asurement used in analogue systems MER represents the ratio of the error power to the average power in an ideal QAM signal Ideally you should have at least 4 or 5 dB of margin from the MER where signi...

Страница 51: ...on a margin of at least 3 or 4 dB is preferred However QAM 256 set decoders require better than 28 dB MER to operate with margins of 3 dB at least Typically the maximum MER displayed on portable analy...

Страница 52: ...formation also The number of levels used in the modulation of each carrier determines the number of possible symbols and consequently the number of bits that can be transmitted in a certain bandwidth...

Страница 53: ...shows the other signal Q in quadrature on a vertical axis to consider the 90 phase change Figure 51 I Q states combination Figure 51 shows the combination of these two signals This image constitutes...

Страница 54: ...hannel plan Figure 52 Frequency offset on the tuning central frequency Taking as example the previous figure if we suppose that in the configuration parameters of the digital channel CH 33 a frequency...

Отзывы: