6 SPECIFICATIONS
Detector type
InGaAs.
Calibrated Wavelength
1310 nm, 1490 nm, 1550 nm and 1625 nm.
Power measurement range
From -60 dBm to +10 dBm.
Wavelength measurement range
1100nm – 1700 nm.
Accuracy
± 0.25 dB
Resolution
0.1.
Memory Storage
200 registers.
Internal Optical Fibre
9 / 125 µm.
Data interface
USB.
Display
LCD.
Connector Type
Universal.
Range of Use
Single-mode/multi-mode
ALIMENTATION
Battery
7.4 V Li Ion Battery.
Low Battery Indicator
Graphic indicator on screen.
Operating time
Approx. 25 h.
Battery Charging
By fast internal charger.
External
Voltage
12 V DC.
Consumption 13
W.
Mains Adapter
From 90 V to 250 V, 50-60 Hz (Included).
ENVIRONMENTAL CONDITIONS
This equipment can be used on the following environmental conditions, on these conditions the
specifications could also be applied:
Altitude
Up to 2.000 m.
Temperature range
From 5 °C to 40 °C.
Max. relative humidity
80 % (up to 31 °C),
decreasing lineally up to 50% at 40 °C.
26
January 2014
Содержание PROLITE-63
Страница 1: ...PROLITE 63 FTTH OPTICAL POWER METER 0 MI2003...
Страница 2: ......
Страница 4: ......
Страница 8: ...January 2014...
Страница 37: ...January 2014 29 7 2 2 Not replaceable fuses by user F001 FUS 2 5 A T 125 V F002 FUS 7 A T 125 V...