Promax FA-665B Скачать руководство пользователя страница 10

 

July 2016 

 
 

  When the two outputs are in series, the voltage  is controlled by master 

output,  but  current  adjustment  of  two  outputs  is  still  independent. 

Therefore, attention should be paid to the position of the CC adjustment 

(6). For example, knob (6) is at the position of counterclockwise to end 

or  current  of  slave  output  excesses  current-limiting  protection  point,  at 

this time, the voltage of slave output will not track the voltage of master. 

So  knob  (6)  should  be  rotated  clockwise  to  maximum  then  the  two 

outputs are in series. 

  By series connection, if there is power output, proper leads corresponding 

to output power should be used to short connect the negative terminal of 

master output with  positive terminal  of  slave output reliably. Since  it is 

shorted  by    a  switchinside  the  unit,  current  will  pass  on  the  shorted 

switch  when  there  is  power  output.  This  will  affect  the  reliability  of  the 

unit. 

 

 

2.2.3

 

 

Parallel using of the two adjustable outputs 

 

  Press in switchs (15) , at this time, the two output are in parallel, adjust 

voltage adjustment (20) of master output, the voltage of two ways keep 

same, and slave output CC indicator (3) lights on.

 

  When  the  two  outputs  are  in  parallel,  the  CC  adjustment  (6)  of  slave 

output  does  not  work.  When  used  as  CC  supply,  simply  adjust  the  CC 

adjustment  (21)  of  master  output,  at  this  time,  output  current  of  both 

master and slave are controlled by it and are same, output current is up 

to double of independent's maximum current. 

  While  the  two  outputs  in  parallel,  proper  leads  corresponding  to  output 

power should be used to short reliably the two positive terminal and the 

Two negative terminals of master, slave output separately, so as to make 

load connected reliably with the two parallel outputs. If the load is only 

connected  to  one  of  the  output  terminals,  unbalance  may  be  caused  to 

current  of  the  two  outputs,  this  may  also  damage  the  series/  parallel 

switchs (15). 

 

NOTE

The LED display is in three digits. To get more accurate measuring value, 

you  should  calibrate  by  external  circuit  with  precision  measuring 

instrument. 

 

 

Содержание FA-665B

Страница 1: ...FA 665B ADJUSTABLE DC REGULATED POWER SUPPLY 0 MI2066 Test Equipment Depot 800 517 8431 99 Washington Street Melrose MA 02176 TestEquipmentDepot com...

Страница 2: ...ph The symbol on the equipment means SEE USER S MANUAL In this manual may also appear as a Caution or Warning symbol WARNING AND CAUTION statements may appear in this manual to avoid injury hazard or...

Страница 3: ...ower cord CA 005 Observe all specified rating both of supply and measurement Remember that voltages higher than 60 V DC or 30 V AC rms are dangerous Use this instrument under the specified environment...

Страница 4: ...h safety Descriptive Examples of Over Voltage Categories Cat I Low voltage installations isolated from the mains Cat II Portable domestic installations Cat III Fixed domestic installations Cat IV Indu...

Страница 5: ...front pannel 2 2 2 Operating method 4 2 2 1 Independence use of two adjustable output 4 2 2 2 Series using of the two adjustable outputs 4 2 2 3 Parallel using of the two adjustable outputs 5 3 SPECIF...

Страница 6: ...range The two outputs can be connected in parallel or in series while the master used for voltage or current adjustment The maximum output voltage in series is double of independent s and the maximum...

Страница 7: ...outputs is in parallel Slave constant voltage indicator the LED illuminates when the slave output is in voltage regulated state Slave constant voltage adjustment adjusting slave output voltage Slave...

Страница 8: ...ad Power switch the unit is ON when this button switch is depressed while CV LED 4 22 or CC LED 3 23 illuminating Fixed output over current indicator the indicator will light if the fixed output is ov...

Страница 9: ...ustment 6 and 21 should be set to maximum but for this unit the current limiting protection point can also be set arbitrarily Setting procedure turn on power rotate counterclockwise the CC adjustment...

Страница 10: ...e two adjustable outputs Press in switchs 15 at this time the two output are in parallel adjust voltage adjustment 20 of master output the voltage of two ways keep same and slave output CC indicator 3...

Страница 11: ...power loss on large power transistors is not very high it can t cause any damage to the unit But there is still power loss when short circuit in order to reduce aging and energy consumption so this si...

Страница 12: ...1 0 mV rms CC 3mA rms Fixed output 10 mV rms Protection Current limit Display accuracy Volt indication 0 2 Rdg 2 digits 2 5 Full Scale Amp indication 1 0 Rdg 2 digits 2 5 Full Scale Mechanical feature...

Страница 13: ...scription of the problem or the service required 4 2 Cleaning Recommendations CAUTION To clean the cover take care the instrument is disconnected CAUTION Do not use scented hydrocarbons or chlorized s...

Страница 14: ...PROMAX ELECTRONICA S L...

Отзывы: