background image

 

 

 

5.6.7

 

 

Output Services 

 

This window gives information about services to be released on the RF output. 

 

 

Figure 14. 

 

Select the RF output (RF 1 to RF 8) to work on. 

 

Then expand the data tree to set the parameters in order to release services at 
the output: 

 

 

Network identifier

: It is the number that identifies the network where 

the signal is distributed. 

 

Network name

: It is the name that identifies the network where the 

signal is distributed. 

 

Transport stream identifier

: It is a number that identifies a specific 

transport stream. 

 

Original network identifier

: It is a number that identifies the network 

from where the signal comes. 

 

Private data specifier

: Data that the receiver uses to properly identify 

the LCN value. 

 

Input

: Select the SAT input (from 1 to 4) to select services. 

 

Manual NIT version

: Enter the version of the Network Information 

Table. If this box is empty the NIT version will be automatically selected 
by the modulator. 

 

Generated services

: It shows services generated from the selected 

transport stream. User can select services by clicking on “Change 
selection” button. 

 

If the user wants to use the same network identifier, network original identifier, 
network name, private data specifier or NIT version on all outputs, use the 

external box and click on “Use for all outputs” box.

 

18

 

June 2021 

Содержание CompactMax-1

Страница 1: ...CompactMax 1 DVB S S2 TO DVB T TRANSMODULATOR 0 MI2032 ...

Страница 2: ......

Страница 3: ...l on the equipment means SEE USER S MANUAL In this manual may also appear as a Caution or Warning symbol WARNING AND CAUTION statements may appear in this manual to avoid injury hazard or damage to this product or other property USER S MANUAL VERSION Version Date Webserver version 1 0 June 2021 1 13 670 ...

Страница 4: ... specified environmental conditions The user is not allowed to perform changes inside the equipment Any change on the equipment must be done exclusively by specialized staff Do not obstruct the ventilation system of the equipment Use appropriate low level radiation cables for input output signals especially on high level signals Follow the cleaning instructions described in the Maintenance paragra...

Страница 5: ...th safety Descriptive Examples of Over Voltage Categories Cat I Low voltage installations isolated from the mains Cat II Portable domestic installations Cat III Fixed domestic installations Cat IV Industrial installations ...

Страница 6: ...1 Introduction 7 5 2 Login 7 5 3 Screen description 9 5 4 Status Area 9 5 5 Edit options 10 5 6 11 Setting parameters 5 6 1 12 Versions Store 5 6 2 13 Control 5 6 3 14 Logs 5 6 4 15 Receivers 5 6 5 16 CAM 5 6 6 17 Input Services 5 6 7 18 Output Services 5 6 8 19 LCNs 5 6 9 20 DVB T modulators 6 SPECIFICATIONS 21 7 MAINTENANCE 22 7 1 22 Instructions for returning by mail 7 2 22 Cleaning Recommendat...

Страница 7: ......

Страница 8: ...signal of the DVB T module can be inserted into a television distribution network The output signal has high quality allowing its way through multiple amplifier stages drifters long cables etc The CompactMax 1 is managed through a webserver via remote control LAN or internet and it is compatible with any standard browser The webserver is easy to use and has multiple setting options The CompactMax ...

Страница 9: ...It can be used in hotels convention centres hospitals ships emblematic buildings mansions etc Figure 1 June 2021 ...

Страница 10: ...June 2021 3 2 PACKAGE CONTENT Main Unit Quick guide Power line ...

Страница 11: ...PTION AND LOCATION ELEMENTS Front view Figure 2 1 Power On indicator 2 Error indicator 3 Common Interface input CI 1 for decoder card 4 Common Interface input CI 2 for decoder card 5 IP address reset June 2021 ...

Страница 12: ...S S2 free channels 9 Input 3 for satellite signal DVB S S2 free channels 10 Input 2 for satellite signal DVB S S2 scrambled channels connected to CI 2 11 Input 1 for satellite signal DVB S S2 scrambled channels connected to CI 1 12 Output for terrestrial RF signal DVB T 13 RF loopthrough input 14 Power connector 110 230 V AC 15 Fuse holder 16 On Off switch 17 Earth connection ...

Страница 13: ...6 June 2021 4 ASSEMBLY INSTRUCTIONS 4 1 Rack mounting Figure 4 4 2 Wall Mounting Figure 5 ...

Страница 14: ...h module IP address Add a new IP or change the current one to meet this requirement Check connections The Ethernet cable must be connected to the control input see description chapter It is recommended to try a ping on the command line interface to confirm they are on the same network range and communication between them is possible Now use a web browser to run the webserver application from the P...

Страница 15: ...5 The error LED will flash Press and hold the button until the LED stops blinking At this time the IP adress has changed to the default IP 192 168 29 30 This change is temporary and if you turn the equipment off you will lose this configuration To save changes connect the webserver application and click on Store fields in the Versions Store tab 8 June 2021 ...

Страница 16: ...as Tab area Each tab access to a specific set of parameters Setting Parameters area Set of parameters according to the tab selected Edit options Options to edit parameters Status area Transmodulator current state 5 4 Status Area The status area shows the current state of input and outputs in the transmodulator Figure 7 ...

Страница 17: ... selected services for each card The radio button shows which one is working and its status green ok red error DVB T modulators It shows the status of the RF output RF muted output frequency and signal source The radio button shows which one is working 5 5 Edit options Edit options are Refresh It reloads data on the webserver application from the transmodulator Modify It applies changes made on th...

Страница 18: ...ator operation Receivers Satellite receivers settings CAM Conditional Access Module CAM settings Input Services Information about services captured from satellite receivers Output Services Selection of services to be released on the RF output LCNs Selection of logical channel number LCN for each service selected DVB T modulators RF output settings to distribute in DVB T standard In next chapters e...

Страница 19: ...quipment name and hardware Store fields button It applies and saves all changes made in the webserver on the transmodulator Reboot button It reboots the transmodulator Reset to factory defaults button It recovers and applies factory settings on the transmodulator Download stored configuration It downloads current configuration as a file from transmodulator to PC Upload and store configuration file...

Страница 20: ...n the transmodulator see description chapter Mask Network parameter Gateway Network parameter Change password It allows the user to change the password to access the webserver application user and password by default Admin Change language It allows the user to select the language of the webserver application Available languages are English and Spanish SI tables charset Select the character set for...

Страница 21: ...ndow gives information about the transmodulator operation Each event happening in the modulator is captured and shown on this window Each event has a description a tag and an identification number Figure 10 14 June 2021 ...

Страница 22: ...requency of the antenna in MHz If you have a Universal LNB generally are 9750 MHz for LOW band and 10600 MHz for HIGH band Downlink frequency MHz Tuning frequency of the satellite Polarization LNB voltage and band Select from the available values 13 V 18 V 13 V 22 kHz 18 V 22 kHz External Generally 13 V is used for VERTICAL polarization and 18 V for HORIZONTAL polarization If you want to tune freq...

Страница 23: ...his window user can browse through the CAM module menu Figure 12 Each time an option is selected user should wait until the module access the next menu or option Each CAM module has its own menu settings 16 June 2021 ...

Страница 24: ...bout the services captured Available information is Transport stream identifier It is a number that identifies the transport stream Original network identifier It is a number that identifies the network from where the signal comes Received services It shows all services detected and its tables Each table shows all the metadata carried in the corresponding PSI SI tables in a tree diagram so user ca...

Страница 25: ...ifier It is a number that identifies the network from where the signal comes Private data specifier Data that the receiver uses to properly identify the LCN value Input Select the SAT input from 1 to 4 to select services Manual NIT version Enter the version of the Network Information Table If this box is empty the NIT version will be automatically selected by the modulator Generated services It sh...

Страница 26: ...ber LCN for each service selected Figure 15 LCN Logical channel number is the number that specifies the index to sort services on the digital terrestrial television receiver There is also one option to auto number all services by filling the First LCN box and clicking on Auto number ...

Страница 27: ...output settings in order to distribute services in DVB T format Figure 16 Select the same RF outputs than selected in the Output services tab Then expand the data tree to set the parameters in order to release services at the output 20 June 2021 ...

Страница 28: ...onstellation QPSK 16QAM 64QAM Code Rate 1 2 2 3 3 4 5 6 7 8 CONDITIONAL ACCES Two Common Interface DVB CI compliant slots TS PROCESSING Selection of arbitrary number of services from the received TS bit rate of the input services selected DVB T output bit rate NULL packet deletion and PCR restamping Regeneration of the PAT PMT SDT NIT tables User defined NID ONID Network Name LCNs with associated ...

Страница 29: ...escription of the problem or the service required 7 2 Cleaning Recommendations CAUTION To clean the cover take care the instrument is disconnected CAUTION Do not use scented hydrocarbons or chlorized solvents The cover should be cleaned by means of a light solution of detergent and water applied with a soft cloth Dry thoroughly before using the system again CAUTION Do not use for the cleaning alco...