background image

EN

5

laser distance measuring device BD21 / BD26

Display

max

min

H
a

a

b

b

18

19

20

21

22

23

24

25

27

26

28

29

30

31

32

33

34

No.

Display element

18

Battery status

19

Horizontal measuring distance

20

Measured minimum value

21

Vertical measuring distance

22

Delta = maximum minus minimum

23

Complementary display when using imperial units

24

Display of the selected unit. Possible units are:
ft

3

, ft

2

, in, m, m

3

, m

2

25

Measured value display:
The lower measurement value display indicates the last
measured value or the result of a calculation. 
The three upper measurement value displays contain the
past three measured values, the minimum and
maximum value or the measured values to be added or
subtracted.

26

History and timer indication

27

 

 Area measurement

  

 Volume measurement

28

 Indirect measurement (two auxiliary measurements)

 Indirect measurement (three auxiliary

measurements)

29

Reference value rear

30

Reference value front

31

Laser active

32

Measured maximum value

33

Timer indication

No.

Display element

34

Inclination angle indication

Technical data

Parameter

Value

Model:

BD21

 / 

BD26

Weight:

150 g

Dimensions (H x W x D):

118 x 49 x 27 mm

Measuring range:

BD21: 0.05 to 70 m
BD26: 0.05 to 120 m

Accuracy:

± 2 mm*

Measuring range resolution: 1 mm

Horizontal measuring range: ±90°

Horizontal measuring range
accuracy:

±0.3°

Number of recordings
logged in the history:

10

Type of protection:

IP54

Operating temperature:

0 °C to 40 °C

Storage temperature:

-20 °C to 70 °C

Laser output:

< 1 mW (620–690 nm)

Laser class:

II

Ø 

 | m

6 mm / 30 mm / 60 mm | 
10 m / 50 m / 100 m

Power supply:

2 x Alkaline LR6 AAA batteries,
1.5 V or NiMH 1.2 V to 1.5 V
(rechargeable batteries)
battery life: approx. 5000 to
8000 measurements

Automatic switch-off of the
device:

After approx. 3 minutes of 
non-use

Automatic switch-off of the
laser:

After approx. 30 seconds of 
non-use

*under favourable conditions (good target surface, room
temperature) up to 10 m

Scope of delivery

1 x Laser distance measuring device

2 x Alkaline LR6 AAA, 1.5 V battery

1 x Device bag

1 x Wrist strap

1 x Quick guide

Содержание TROTEC BD21

Страница 1: ...TRT BA BD21 BD26 TC2015 40 004 EN BD21 BD26 EN OPERATING MANUAL LASER DISTANCE MEASURING DEVICE ...

Страница 2: ...1523 Safety Read this manual carefully before starting or using the device Always store the manual in the immediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in electric shock fire and or serious injury Save all warnings and instructions for future reference This appliance can be used b...

Страница 3: ...forbidden Personnel qualifications People who use this device must be aware of the dangers that occur when working with laser measuring devices have read and understood the operating manual especially the Safety chapter Residual risks Warning of laser radiation Laser class 2 P max 1 mW λ 400 700 nm EN 60825 1 2014 Do not look directly into the laser beam or the opening from which it emerges Never ...

Страница 4: ...rs colourless liquids e g water dust free glass styrofoam or other semi permeable materials The measurement result may also be falsified if the laser encounters a high gloss surface and is deflected by it Non glossy non reflective or dark surfaces can extend the measurement duration Device depiction DIST TIMER Units CLEAR OFF 6 1 2 3 4 5 No Designation 1 Battery compartment opening 2 Multifunction...

Страница 5: ...value front 31 Laser active 32 Measured maximum value 33 Timer indication No Display element 34 Inclination angle indication Technical data Parameter Value Model BD21 BD26 Weight 150 g Dimensions H x W x D 118 x 49 x 27 mm Measuring range BD21 0 05 to 70 m BD26 0 05 to 120 m Accuracy 2 mm Measuring range resolution 1 mm Horizontal measuring range 90 Horizontal measuring range accuracy 0 3 Number o...

Страница 6: ...re the device Operation Inserting the batteries Attaching the wrist strap Switch on 1 Briefly press the Switch on measurement button 7 ð The display will be switched on and the device ready for operation Switch off 1 Press the Switch off button 12 for a long time ð The display is switched off Using the multifunctional end piece The device is equipped with a multifunctional end piece 2 which you ca...

Страница 7: ...es be displayed in the xx yy format Displaying the inclination 1 Briefly press the Inclination button 15 ð The inclination of the device will be indicated in the Inclination display 34 Calling up a measured value in the device history The device automatically saves the last 10 measured values The saved measured values can be called up as follows 1 Press the Save button 13 to call up the history 2 ...

Страница 8: ... the Area room volume button 16 twice ð The symbol for volume measurement appears on the display ð The side to be measured in each case is indicated on the display by flashing 2 Briefly press the Switch on measurement button 7 to carry out the first measurement e g length 3 Briefly press the Switch on measurement button 7 again to carry out the second measurement e g width 4 Briefly press the Swit...

Страница 9: ...alculation are effected ð The horizontal 1st line and vertical 2nd line distance values are indicated in the upper measurement value display ð The line segment to be determined is displayed as result in the lower measurement value display 25 Measurement with distances A and B 1 Briefly press the Button for indirect measurements 9 one time ð The symbol for indirect measurements appears on the displ...

Страница 10: ... line of the upper measurement value display ð The angle will be indicated in the second line of the upper measurement value display ð The line segment to be determined is displayed as result in the lower measurement value display 25 Measurement with distances A B and C 1 Briefly press the Button for indirect measurements 9 twice ð The symbol for indirect measurements appears on the display 2 Pres...

Страница 11: ...ollowing list The following fault indications can appear in the lower measurement value display together with the word INFO Indicati on Cause Remedy 101 The reception of the reflected signal is too weak Repeat measurement on another surface with better reflective properties or use a target plate 102 The reception of the reflected signal is too strong 201 The ambient light is too intense Change the...

Отзывы: