background image

Table Of Contents

Safety and Precautions... 

  pages 1-2

Installation Preparations...

  pages 2-3

Overview...

      

    

   pages 3-4

Features...

      

    

        page 5

Installation Guidelines...

   pages 5-9

Testing Your Inverter...

      page 10

Operation...

            

            pages 11-12

Optional Remote Installation... 

            pages 12-13

Trouble Shooting...

      

            pages 14-17

Specification...

                                              page 18

Customer Service & Warranty... 

      page 19

Introduction

Thank you from all of us at On Board Solutions, A ProMariner Company.
Congratulations on your recent purchase of a TruePower Inverter!

Leading the Marine industry in Power Conversion for over 30 years, ProMariner’s On
Board Solutions division has designed a complete line of Power Inverters ranging from
200 to 3,000 watts specifically for Marine / Industrial use. TruePower Inverters will
convert your OnBoard 12Vdc Battery power to 110Vac Household Power to run TV’s,
Laptops, Gaming Systems, power tools, hairdryers, coffee makers, blender’s, large
appliances and more.

Please save and read this manual carefully and fully understand the safety instructions
before installing your new TruePower Inverter.

C u s t o m e r   S e r v i c e   &   W a r r a n t y

19

Customer Service & Warranty

We are committed to customer satisfaction and value your business. If at any time
during the warranty period you experience a problem with your new TruePower Inverter
simply call us at 1-800-824-0524 during standard business hours (8:30 AM – 5 PM
Eastern Time) for technical support.

TRUEPOWER

TWO YEAR LIMITED FACTORY WARRANTY

Each product is guaranteed against defects in material and workmanship to the original consumer in normal
use for two full years from the date of purchase. On Board Solutions and Professional Mariner, LLC at its
discretion will repair or replace free of charge any defects in material or workmanship. The following
conditions apply:

• Warranty is calculated from date of manufacture if not registered within two weeks of sale.

• Warranty void if damage occurs due to negligent repairs.

• Customer is responsible for returning the product to On Board Solutions and Professional
  Mariner, LLC. inbound shipping costs must be prepaid.

• This warranty does not cover blemishes due to normal wear and tear or damages caused
   by accidents, abuse alterations or misuse.

Purchase or other acceptance of the product shall be on the condition and agreement that On Board Solutions and
Professional Mariner SHALL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY KIND.
(Some states do not allow the exclusion or limitation of consequential damages, so the above limitations may not
apply to you.) This warranty is made in lieu of all other obligations or liabilities on the part of Onboard Solutions and
Professional Mariner. Additionally, On Board Solutions and Professional Mariner neither assumes nor authorizes
any person for any obligation or liability in connection with the sale of this product.

To make a claim under warranty, call Factory Service at 1-800-824-0524. Follow the company’s return policy, which
will be provided by the company. On Board Solutions and Professional Mariner will make its best effort to repair
or replace the product, if found to be defective within the terms of the warranty, within 30 days after return of the
product to the company. On Board Solutions and Professional Mariner will ship the repaired or replaced product
back to the purchaser.

The GFCI is covered by a 90 day warranty limitation, as the life of a GFCI in a harsh, humid, outdoor marine
environment cannot be guaranteed. The GFCI is a standard off the shelf serviceable / replaceable component
in the TruePower Inverter Series. Please contact Customer Service for additional assistance.

This warranty provides to you specific legal rights and you may also have other rights, which vary from state to
state. This warranty is in lieu of all other, expressed or implied.

OBS & Professional Mariner, LLC.

Factory Service Center

200 International Drive, Suite 195

Portsmouth, NH 03801

Service Phone: 1-800-824-0524

Phone: (603) 433-4440

Fax: (603) 433-4442

Visit us on the web at: www.promariner.com

www.onboardsolutions.biz

Содержание TruePower 05150

Страница 1: ...rter 00 Watt 05174 24 VDC Input 1700 Watt 110 VAC Output Inverter 00 Watt 05204 24 VDC Input 2000 Watt 110 VAC Output Inverter 00 Watt 05254 24 VDC Input 2500 Watt 110 VAC Output Inverter 00 Watt 05304 24 VDC Input 3000 Watt 110 VAC Output Inverter OnBoard Solutions A ProMariner Company roMariner TruePowerInverterSeries 500 3000Watt High Power Models Owner Manual Installation Guide Heavy Duty Mari...

Страница 2: ...tulations on your recent purchase of a TruePower Inverter ading the Marine industry in Power Conversion for over 30 years ProMariner s On oard Solutions division has designed a complete line of Power Inverters ranging from 0 to 3 000 watts specifically for Marine Industrial use TruePower Inverters will onvert your OnBoard 12Vdc Battery power to 110Vac Household Power to run TV s ptops Gaming Syste...

Страница 3: ...12V 12V 24V 12V 24V 12V 24V 12V 24V ontinuous Power 1500W 1700W 2000W 2500W 3000W urge Power 3000W 3400W 4000W 5000W 6000W utput Waveform Modified Sine Wave C Output voltage 115V 10 C Output amps up to continous 13 6 15 5 18 2 22 7 27 3 C Input Voltage 10V 15V 10V 15V 20V 30V 10V 15V 20V 30V 10V 15V 20V 30V 10V 15V 20V 30V C Input Amps up to 150A 170A 85A 200A 100A 250A 125A 300A 150A ficiency 85 ...

Страница 4: ...nstall in compartments ontaining gasoline fueled engines or gasoline tank or in areas where ignition otected equipment is required WARNING Do not mount the inverter above or below your batteries WARNING Electrical shock and fire hazards n Board Solutions a ProMariner Company recommends all wiring be done by ualified personnel Disconnect all AC and DC power sources to prevent accidental hock Disabl...

Страница 5: ...The fan will run at full speed when the inverter is powering a higher rated appliance Possible Cause The ambient temperature is high Solution No action The fan will run at a higher ambient temperature to keep the inverter cool Low Battery alarm sounds continuously Possible Cause Bad wiring or connection Solution Tighten and clean all DC connections Power tool will not start Possible Cause Large st...

Страница 6: ...bulletspointingoutdigital argraphdisplay on offswitch ledlocationsetc PleaseReferenceTablebelowforfeatures ON Off Switch turns the inverter to ON OFF Power light illuminates when inverter is on Fault Light illuminates Red for fault conditions such as over temperature output overload or battery low voltage Two GFCI Protected AC Outputs to power connected appliances Reset and Test monthly capabiliti...

Страница 7: ...rload check the AC wiring and reset the breaker by turning the ON Off switch to Off and then back to ON Possible Cause GFCI has tripped Solution Clear the ground fault and reset the GFCI by pressing the reset on the GFCI button No AC output voltage Red Fault LED light is illuminated roubleshooting his section is designed to accommodate you in identifying and troubleshooting ommon problems that may...

Страница 8: ...on Select an appropriate mounting location and orientation Hold the inverter against the mounting surface mark the position of the mounting crews and then remove the inverter Drill pilot holes for the four mounting fasteners Use caution prior to drilling or cutting ensure proper clearance from existing wiring and hardware Fasten the inverter to the mounting surface with four hardware fasteners ote...

Страница 9: ...lly reset to operating levels perating Several Appliances at the Same Time you are going to operate several appliances at the same time turn them on dependently after you have powered up the inverter This action ensures that the uePower does not have to deliver the starting current for all of the appliances at nce The TruePower can accommodate several appliances at once as long as they o not excee...

Страница 10: ...quirement of ur inverter This battery bank requires a attery charging system youareusingdifferentbatteries orneedtousemorethattwobatteries werecommend at you set up two separate battery banks and use them alternately Battery selector witches are available from Marine and RV Dealers which allow the user to select etween two banks of batteries or use both in parallel or disconnect both banks from e ...

Страница 11: ...provides AC power n the Off position the TruePower Inverter draws no current from the battery None of e front panel LED lights are illuminated TheFaultLightIlluminatesRedwhenafaultconditionssuchasovertemperature output verload or battery low voltage occurs test the TruePower Inverter Turn the On Off switch to the ON position The Inverter Fault LED light illuminates Green Plug an appliance of equal...