Proluxe TACO BELL PROGRILL SL1577TBCEC Скачать руководство пользователя страница 7

DOUGHPRO

SL1577 Split Lid Grill Trouble Shooting Guide

Symptom

Probable Cause

Action to be Taken

Parts List Ref. #

Either Heater Platen is not Heating 
but the Digital Controller is on and 
appears to be functioning.

If the Mechanical Relay (s) on the coil 
side are receiving 12vdc  indicates the 
Controller is functioning properly.  On 
the switching side of the relay, is the 
rated voltage for the Model(120,208, 
or 220~AC) going to the heater in 
question?  If there is no voltage on 
the to the switching side of the relay 
to the heaters, the Relay is not 
working properly  

 Replace Mechanical Relay. 

# 15

Heater Platen overheating

The mechanical Relay may be stuck in 
the closed position (zone 1, Lower 
Platen #1 labeled on this relay, zone 
2, left upper and zone 3, right upper).

Replace Mechanical Relay.

# 15

If  you are receiving 12vdc on the coil 
of the relay, the Controller is properly 
functioning thus maybe you have a 
break in the wire to the heater (s) or 
the Heater Platen lost it's continuity

One of the Heater's embedded into 
to the Heated Aluminum Platen may 
have lost Continuity.  With use of a 
Ohm Meter a condinuity check must 
check at the cold pins of the heater 
(where the heater wire is brazed at 
the cold pin.  This will eliminate any 
other failue before the the heater 
element validating the loss off 
condinuity at the source (Heater 
Element).  If so, either the Upper left 
(zone 2), right (zone 3) or Lower, 

#15

Either Upper Heater not coming 
down parallel to the Lower Heater 
Platen.

Parallel Lever not attached either in 
the rear out on the Upper Heater 
Platen.  Check to see if Parallel leveler 
is connected on both sides. The 
retaining clip attached to pin may 
have come off.

Reconnect the pin and the retaining  
E-Clip.

# 25

Upper Platen falling down or lost It's 
retension .

Possibly the Springs (2, one for each 
Upper Heater Platen has lost some 
retension.

Remove rear panel and adjust the 
retaining collars on shaft by winding 
spring tighter.  There are mutlple set 
screws that need to be loosened in 
order to wind the spring tighter.  
Once achieving proper tension be 
sure to tighten all set screws so that 
tension isn't lost again.

___

If one heating zone is not reaching 
setpoint and another heater is 
overheating

Sensors maybe crossed

Make sure each sensor is connected 
to it's prospective postion on the 
terminal block which in turn to the 
Controller.

___

Содержание TACO BELL PROGRILL SL1577TBCEC

Страница 1: ...formerly DOUGHPRO New Name Same Quality Superior Service proluxe com Operations Manual Model SL1577TBCEC Split Lid Grill rev1 42814...

Страница 2: ...the power switch which will illuminate when turned on The display flashes and shows left preset timer during warm up Pre heat temperature time will be 40 50 minutes When the set point is reached the d...

Страница 3: ...is turned on All preset LED s are turned off and the temperature set point is changed to the clean set point of 275 F This also initiates the cool down to clean set point condition as well the displa...

Страница 4: ...temperature of the UPPER PLATENS Press the TEMPERATURE button and the ARROW UP button at the same time 2 To find the temperature of the LOWER PLATENS Press the TEMPERATURE button and the ARROW DOWN bu...

Страница 5: ...imer button and continue to hold both for 5 seconds The digital displays will now read their preset times as shown here Each side is capable of having up to 4 different settings making a total of 8 se...

Страница 6: ...Upper Platen has the open sensor or probe same goes for the down arrow indicating Lower Platen Sensor in one of two zones lost it s continuity Depress Temp While depressing Temp depress either up or...

Страница 7: ...ith use of a Ohm Meter a condinuity check must check at the cold pins of the heater where the heater wire is brazed at the cold pin This will eliminate any other failue before the the heater element v...

Страница 8: ...79 2X 40 54 45 1 4X 28 52 4X 42 4X 2X 63 71 4X 70 75 3 64 12X 52 77 4X 76 78 2X 74 2X 73 2X 72 2X 46 2X 55 2X 2 68 A1 A2 EXPSL1577TBCEC RC 101216 SHEET 1 OF 2...

Страница 9: ...83 2X 22 2X 21 2X 20 2X 5 2X 6 2X 14 92 6X 53 6X 31 6X 93 6X 94 3X 95 69 48 30 84 10 8X 66 65 3X 13 3X 9 6X 4 35 39 34 2X 48 17 2X 2X 19 37 18 2X 44 29 89 3X 90 17 3X 3X 91 36 4X 41 49 32 2X 15 12X 24...

Страница 10: ...9 BUSHING TEFLON 3 4 LONG 110113441 110113441 6 30 GREASE TRAY 110115505 110115505 1 31 NUT HEX 6 32 NH632 NH632 12 32 TOP LINK 110115508 110115508 2 33 WIRE HARNESS 1101102050 1101102050 1 34 UPPER L...

Страница 11: ...513 1 82 SCREW SET 3 8 16 x 1 2 SST381612 SST381612 2 83 RTD SENSOR 1108881101 1108881101 2 84 SCREW PAN HEAD PHILLIPS 10 24X3 8 STAINLESS STEEL SP102438S SP102438S 12 85 SHROUD LEFT ASSEMBLY 11016546...

Страница 12: ......

Страница 13: ......

Страница 14: ...pany s products the following instructions must be adhered to First contact our customer service department for approval and a return authorization number Please have the serial number of your item av...

Отзывы: