Proluxe PIEOLOGY DOUGHPRO DP2000PIP Скачать руководство пользователя страница 4

 

-3- DP2000-1725-7/04 

 

 

WARNING 

In case of power cord damage, 
do not attempt to repair or 
replace the power cord.  Contact 
the manufacturer or the local 
distributor. 

 
 

WARNING

 

Avoid touching hot surfaces 
while operating the machine. 

 

CAUTION 

During normal operation, the 
base of the machine must be 
installed or placed above the wall 
socket. 

 

 CAUTION 

When servicing or cleaning the 
machine, make sure that the 
power cord is removed from the 
wall socket. 

 

Control Board Operations 
 

 

 
 
 
 
 
 
Solid State Controller 

 
This controller has three (3) control 
features: 
 

1.

 

Temperature – Temperature may 
be set from 

0

°-450°F (

0

°-

232°C).  The factory default 
setting is 2

40

°.  If you would like 

to change this setting, simply 
follow the 

Controller Operation

 

directions. 

 

2.

 

Counter – Cycle counter counts 
the number of applications from 
1 to 

9999

 

(see additional Notes – 

Counter).

 

 

3.

 

Timer – A timer mode is 
available upon special request.  If 
you would like to have the timer 
function installed, please call     
1-800-624-6717 

 
Controller Operation 
 

Temperature Control 

 

1.

 

Press the 

MODE 

button until 

temperature is displayed. 

 

2.

 

Push and hold 

SET

 button and 

simultaneously push UP (

V

) or 

DOWN (

W

) arrow buttons to the 

desired temperature setting. 

 

For the DP2000, both the upper 
and lower platens may be set to 
different temperatures. 
   

 

Upper Platen:

  Simply 

push the 

MODE 

button 

until the “upper” light is 
illuminated.  Adjust the 
temperature as noted 
above.   

 

Lower platen:

  Simply 

push the 

MODE

 button 

until the “lower” light is 
illuminated.  Adjust the 
temperature as noted 
above. 

 

 

 

 
 
 
 

Содержание PIEOLOGY DOUGHPRO DP2000PIP

Страница 1: ...formerly DOUGHPRO New Name Same Quality Superior Service proluxe com Operations Manual Model DP2000PIP Dual Heat Dough Press...

Страница 2: ...rate 30 amp AC circuit Only industrial extension cords with proper wire size should be used size 16 3 wire for distance up to 25 feet and size 14 3 for distance up to 50 feet INTERNATIONAL Use a desig...

Страница 3: ...antability and fitness for a particular use and is accepted such by the purchaser in taking delivery of this product Specifications Electrical 208V 50 60Hz 4600W 22 11Amps Requires 30 AMP outlet Inclu...

Страница 4: ...to change this setting simply follow the Controller Operation directions 2 Counter Cycle counter counts the number of applications from 1 to 9999 see additional Notes Counter 3 Timer A timer mode is...

Страница 5: ...fferent products require different temperature settings In order to determine the right temperature setting for your product refer to the following table simply as a guide for starting To achieve cons...

Страница 6: ...reen or in a pan Since the shape of the dough may be altered slightly in the transfer process some hand fitting may be required Add toppings if desired and now you are ready to bake ADDITIONAL NOTES T...

Страница 7: ...should be followed Daily Care 1 Platens These platens should only be cleaned with mild soap and warm water then wiped off with a clean soft cloth or soft sponge Never use steel wool or harsh abrasives...

Страница 8: ...on the right side of the vertical post Machines with swing away upper heads have two grease ports one on the right side of the vertical post and one on the back of the vertical post All other machines...

Страница 9: ...hrough LED segment check 8888 then to version and then loops back to to the above reboot The relay driver on the digital control may be blown Replace Digital Controller Digital display shows PROB No h...

Страница 10: ...alse reading as well Replace Relay If the Controller s heat on LED is not lit indicating the controller is working properly If this is not the issue replace sensor Dough not having same thickness acro...

Страница 11: ......

Страница 12: ...R CORD 110573175 1 27 SET SCREW BASE GROUND SST8321 1 28 TENSION STRAP ASSEMBLY 11041663 1 29 HANDLE PRESSURE 1109390 1 30 ARM 1109842101 1 31 SCREW BASE COVER PLATE SP83214 6 32 GEAR BAR 1109361 1 33...

Страница 13: ...M RETAINING PLATE SSH1213112 1 79 BUSHING INSULATING 1 2 110966022 1 81 ZERK FITTING B610 1 82 SET SCREW HANDLE SOCKET SST14201 3 84 MARKER STRIP MS6016 1 85 WASHER SAE 1 2 WSAE12 2 86 TUBE WIRE SUPPO...

Страница 14: ......

Страница 15: ...pany s products the following instructions must be adhered to First contact our customer service department for approval and a return authorization number Please have the serial number of your item av...

Отзывы: