DP2000 Trouble Shooting Guide

Symptom

Probable Cause

Action to be Taken

Power Button on Digital Controller 
face is depressed but doesn’t turn 
on.

Power Cord is not plugged in.

Plug power cord into wall 's receptacle 
and depress power button on 
controller

Circuit Breaker is tripped off in the 
site's breaker box

Reset circuit breaker that the Grill is 
plugged into. Depress Power Button to 
turn on.

Transformer has taken a electrical 
surge and is damaged

Replace Transformer after you check 
secondary side of transformer.  If 
working properly, you should receive 
12vdc.

Check voltage on the secondary side 
of the Transformer.  If you read 
12VDC then you are receiving voltage 
to the Controller.

Replace Controller.  Controller should 
be on once the power button is 
depressed.

Possibly blown Fuse

Replace fuse.

Digital Controller's LED's are 
scrambled or randomly irratic.  If 
when turning on, the display will 
first go to segment check

Possibly a componet on the Digital 
Controller is damaged

 Replace Digital Controller

Possibly control needs to reset

While unit is on (controller lit up) 
Unplug unit, wait for 1 min. then plug 
machine on and depress power button.

Digital Controller on startup goes 
through LED segment check (

8888

then to version # and then loops 
back to to the above reboot.

The relay driver on the digital control 
may be blown.

Replace Digital Controller.

Digital display shows 

PROB.  

No 

heat on Upper Platen or Lower 
Platen. 

Sensor lost it's continuity as shown 
on a muti-meter.

Disconnect prob that is open (no 
continuity as shown on  a multi-meter. 
Must replace Sensor (RTD).  Do not cut 
and splice new sensor. Install new 
2000 ohm RTD sensor to under side of 
Heat Platen and reconnect to 
Controller.

When depressing the tactile button 
on Digital Controller, nothing 
happens.

The tactile buttons under the overlay 
may be not close enough to activate. 
Same goes if the buttons are already 
pressed by overlay without 
depressing button.

Carefully (no too much at one time to 
avoid fracturing the traces on the 
Controller) tighten the nuts on the 
back of the Controller until button 
activate. Same goes in reverse if 
buttons are held down by the overlay.  

Digital display shows 

Relay 

and  

Particular zone is over heating or 
outer zone).

The  Relay on the switched side is not 
opening to regulate temperture.  

Replace the Relay.

Beeper not functioning or 
intermitten beeper sound.

Beeper on Digital Control board 
failed.

Replace Digital Controller board

If setpoint is reached but slighty off 
in temperature.

Offset may need to be calibrated and 
adjusted.

Must call (800) 624-6717 ext. 129   for 
confidential instructions.

Содержание DP2000CE

Страница 1: ...Operations Manual Endurance X2 Dual Heat Manual Dough Press Model DP2000CE WWW PROLUXE COM Version 41219...

Страница 2: ...rate 15 amp AC circuit Only industrial extension cords with proper wire size should be used size 16 3 wire for distance up to 25 feet and size 14 3 for distance up to 50 feet INTERNATIONAL Use a desig...

Страница 3: ...antability and fitness for a particular use and is accepted such by the purchaser in taking delivery of this product Specifications Electrical 240V 50 60Hz 3000W 12 5Amps Requires 30 AMP outlet Includ...

Страница 4: ...ke to change this setting simply follow the Controller Operation directions 2 Counter Cycle counter counts the number of applications from 1 to 9999 see additional Notes Counter 3 Timer A timer mode i...

Страница 5: ...fferent products require different temperature settings In order to determine the right temperature setting for your product refer to the following table simply as a guide for starting To achieve cons...

Страница 6: ...reen or in a pan Since the shape of the dough may be altered slightly in the transfer process some hand fitting may be required Add toppings if desired and now you are ready to bake ADDITIONAL NOTES T...

Страница 7: ...should be followed Daily Care 1 Platens These platens should only be cleaned with mild soap and warm water then wiped off with a clean soft cloth or soft sponge Never use steel wool or harsh abrasives...

Страница 8: ...on the right side of the vertical post Machines with swing away upper heads have two grease ports one on the right side of the vertical post and one on the back of the vertical post All other machines...

Страница 9: ...gh LED segment check 8888 then to version and then loops back to to the above reboot The relay driver on the digital control may be blown Replace Digital Controller Digital display shows PROB No heat...

Страница 10: ...alse reading as well Replace Relay If the Controller s heat on LED is not lit indicating the controller is working properly If this is not the issue replace sensor Dough not having same thickness acro...

Страница 11: ...42 56 55 56 28 18 62 A2 A1 A3 20 A4 108 38 100 95 104 83 96 94 2X 102 95 103 95 94 98 2X 97 106 97 101 102 103 96 83 97 94 95 108 109 97 101 81 90 61 103 92 107 4X 109 105 103 105 22 06 01 18 EXPLOSI...

Страница 12: ...4X 63 4X 53 4X 84 79 51 3X 66 65 29 5 25 70 17 67 41 31 44 30 69 35 38 8 34 17 70 5 17 33 A5 17 112 72 2X 35 43 33 42 27 81 56 79 55 56 38 55 36 74 75 38 73 43 10 78 19 47 35 12 4X 54 26 11 4X 64 39...

Страница 13: ...POWER 220 AC European MPPW202 MPPW202 1 25 ORING 2 238 N 70 PISTON 238N70 238N70 1 26 WASHER STEEL 311 O D X 150 I D X 20 THK 311150019 311150019 4 27 MARKER STRIP TERMINAL BLOCK ARM 2 SINGLE MS6992 M...

Страница 14: ...42034CP SST142034CP 1 73 FUSE HOLDER 1 AMP MPPF708 MPPF708 1 74 FUSE 1 AMP 250V 250W LOW BLOW MPPF701R MPPF701R 1 75 SCREW PHILLIPS PAN 2 56 x 1 4 SP25614 SP25614 1 76 FEET RUBBER RF209 RF209 5 77 ACT...

Страница 15: ...33 50 FT 107 TERMINAL 6 RING x 18 22 GA 2202 2202 2 108 DP INSULATION 1101171251 1101171251 2 109 HEAT SHROUD 1109336 1109336 2 110 ASSEMBLY CAM RAMP 1109310 1109310 1 112 GEAR PINION 1109360 1109360...

Страница 16: ......

Страница 17: ...f the company s products the following instructions must be adhered to First contact our customer service department for approval and a return authorization number Please have the serial number of you...