DP1100 Trouble Shooting Guide

Symptom

Probable Cause

Action to be Taken

Power Button on Digital Controller 
face is depressed but doesn’t turn 
on.

Power Cord is not plugged in.

Plug power cord into wall 's receptacle 
and depress power button on 
controller

Circuit Breaker is tripped off in the 
site's breaker box

Reset circuit breaker that the Grill is 
plugged into. Depress Power Button to 
turn on.

Transformer has taken a electrical 
surge and is damaged

Replace Transformer after you check 
secondary side of transformer.  If 
working properly, you should receive 
12vdc.

Check voltage on the secondary side 
of the Transformer.  If you read 
12VDC then you are receiving voltage 
to the Controller.

Replace Controller.  Controller should 
be on once the power button is 
depressed.

Possibly blown Fuse

Replace fuse.

Digital Controller's LED's are 
scrambled or randomly irratic.  If 
when turning on, the display will 
first go to segment check

Possibly a componet on the Digital 
Controller is damaged

 Replace Digital Controller

Possibly control needs to reset

While unit is on (controller lit up) 
Unplug unit, wait for 1 min. then plug 
machine on and depress power button.

Digital Controller on startup goes 
through LED segment check (

8888

then to version # and then loops 
back to to the above reboot.

The relay driver on the digital control 
may be blown.

Replace Digital Controller.

Digital display shows 

PROB.  

No 

heat on Upper Platen. 

Sensor lost it's continuity as shown 
on a muti-meter.

Disconnect prob that is open (no 
continuity as shown on  a multi-meter. 
Must replace Sensor (RTD).  Do not cut 
and splice new sensor. Install new 
2000 ohm RTD sensor to under side of 
Heat Platen and reconnect to 
Controller.

When depressing the tactile button 
on Digital Controller, nothing 
happens.

The tactile buttons under the overlay 
may be not close enough to activate. 
Same goes if the buttons are already 
pressed by overlay without 
depressing button.

Carefully (no too much at one time to 
avoid fracturing the traces on the 
Controller) tighten the nuts on the 
back of the Controller until button 
activate. Same goes in reverse if 
buttons are held down by the overlay.  

Digital display shows 

Relay 

and  

Particular zone is over heating or 
outer zone).

The  Relay on the switched side is not 
opening to regulate temperture.  

Replace the Relay.

Beeper not functioning or 
intermitten beeper sound.

Beeper on Digital Control board 
failed.

Replace Digital Controller board

If setpoint is reached but slighty off 
in temperature.

Offset may need to be calibrated and 
adjusted.

Must call (800) 624-6717 ext. 129   for 
confidential instructions.

Содержание DP1100A

Страница 1: ...Operations Manual Endurance X1 Manual Dough Press Model DP1100 WWW PROLUXE COM Version 101417 ...

Страница 2: ...Perris ...

Страница 3: ......

Страница 4: ......

Страница 5: ......

Страница 6: ......

Страница 7: ......

Страница 8: ......

Страница 9: ......

Страница 10: ...oes through LED segment check 8888 then to version and then loops back to to the above reboot The relay driver on the digital control may be blown Replace Digital Controller Digital display shows PROB No heat on Upper Platen Sensor lost it s continuity as shown on a muti meter Disconnect prob that is open no continuity as shown on a multi meter Must replace Sensor RTD Do not cut and splice new sen...

Страница 11: ...Replace Relay If the Controller s heat on LED is not lit indicating the controller is working properly Dough not having same thickness across the press dough To adjust upper platen for level press Underneath the arm resting on the Upper Platen Shroud you will find 4 stacked hex bolts sitting over the upper platen attach to the arm The top bolts are called locking bolts The 4 larger Hex Bolts below...

Страница 12: ... RE 050218 CUSTOMER MANUAL DP1100 EXPLOSION VIEW A1 A2 A3 20 18 40 59 24 23 4X 22 4X 21 4X 19 1 3 62 57 60 4X 61 6X 67 68 88 92 93 91 87 90 94 3X 86 77 79 84 71 83 75 74 82 73 81 78 4X 80 72 76 69 06 01 18 4 100 ...

Страница 13: ...X 49 4X A5 A4 49 4X 50 4X 37 6 47 52 4X 51 4X 6 37 66 66 27 27 10 41 2X 8 43 12 11 45 44 26 45 44 26 42 26 14 38 13 29 30 39 39 15 25 65 99 33 98 97 2 16 5 96 95 EXPDP1100 RE 050218 CUSTOMER MANUAL 33 35 39 9 31 101 101 32 17 34 36 101 63 64 70 ...

Страница 14: ...45 5806282 5806282 5806282 5806282 5806282 5806282 1 30 CLIP E RETAINING 1 2 MPSC240 MPSC240 MPSC240 MPSC240 MPSC240 MPSC240 1 31 BRACKET HOUSING ASSEMLBY 110144130 110144130 110144130 110144130 110144130 110144130 1 32 SCREW SOCKET HEAD 1 4 20 X 3 1 4 SSH1420314 SSH1420314 SSH1420314 SSH1420314 SSH1420314 SSH1420314 1 33 NUT HEX 1 4 20 NH1420 NH1420 NH1420 NH1420 NH1420 NH1420 3 34 BUSHING TENSIO...

Страница 15: ... OPVC1050 OPVC1050 OPVC1050 OPVC1050 OPVC1050 1 33 FT 83 TERMINAL FEMALE MOLEX MPSQ100 MPSQ100 MPSQ100 MPSQ100 MPSQ100 MPSQ100 1 84 TERMINAL RING 6 1601HT 1601HT 1601HT 1601HT 1601HT 1601HT 1 86 SHROUD UPPER PLATEN 1109336 1109336 1109336 1109336 1109336 1109336 1 87 KNOB SWING AWAY 110017 110017 110017 110017 110017 110017 1 88 FLANGED BUSHING MACHINED 110102167 110102167 110102167 110102167 1101...

Страница 16: ......

Страница 17: ...of the company s products the following instructions must be adhered to First contact our customer service department for approval and a return authorization number Please have the serial number of your item available at that time All merchandise must be shipped freight prepaid by customer or service agency Subject to the inspection of the product by the company a restocking charge of 20 of the Ne...

Отзывы: