background image

 

-2- DP1300 

 

2/04 

 
 

WARNING

 

Avoid touching hot surfaces 
while operating the machine. 

 

CAUTION 

During normal operation, the 
base of the machine must be 
installed or placed above the wall 
socket. 

 

 CAUTION 

When servicing or cleaning the 
machine, make sure that the 
power cord is removed from the 
wall socket. 

 

Operation Timer/Temperature 
Control 
 

 

  Fig. 

 
Solid State Controller 
 

This controller has three (3) control 
features: 
 

1.

 

Temperature – May be set from 
100°-425°F (38°-163°C) 

 
2.

 

Time – Time may be set from 1 
second to 10 minutes. 

 

3.

 

Counter – Cycle counter counts 
the number of applications from 
1 to 9999 (see additional Notes – 
Counter). 

 

4. “

2

Lower” (Fig. A) Refers to 

models using upper and lower 
heated surfaces. 

 
Controller Operation 

1.

 

Viewing the Modes of Operation:

   

• To view the set points of 
temperature, timer and counter, 
press MODE button to view the 
desired mode of operation. 

 

2.

 

Changing Temperature: 

• Press 

MODE

 button until 

temperature is displayed. 
• Press and hold 

SET

 button  

while pressing the 

UP

 (

) and 

DOWN

 (

) arrow buttons to 

desired temperature setting. 
 

3.

 

Changing Time: 

• Press 

MODE

 button until time 

is displayed. 
• Press and hold 

SET

 button  

while pressing the 

UP

 (

) and 

DOWN

 (

) arrow buttons to 

desired timer setting. 
 
The 

DISENGAGE

 switch may 

be pressed anytime during a 
cycle, and the cycle will stop 
immediately, and the timer will 
reset. 

 
      4.

 

Resetting the Counter 
• 

Press MODE button until the 

counter is displayed. 
• To Reset the Counter (# of 
Cycles),  simultaneously push 
UP (

)  or DOWN (

) arrow 

buttons (approx. 5 seconds). 

 

PRESSING DOUGH: 
For best results, your dough should be 
proofed before pressing, but it will also 
press directly out of your refrigerator.  

Flour is not required to press a crust 
and should not be dusted on any part of 
the machine.

   

 

D1400C Cabinet & Compressor 

1.

 

After connecting the air hose line 
from the compressor to the press, 
plug it into the properly rated 
electrical outlet for your press 
and air compressor cabinet.  
Verify the electrical requirements 
against the nameplate on the 

2/10

Содержание Doughpro DP2300BZE

Страница 1: ......

Страница 2: ...f the press itself Limited Machine Warranty Doughpro warrants this dough press machine when operated under normal conditions to be free from manufacturing defects in material and workmanship for a per...

Страница 3: ...s MODE button until temperature is displayed Press and hold SET button while pressing the UP and DOWN arrow buttons to desired temperature setting 3 Changing Time Press MODE button until time is displ...

Страница 4: ...ness is determined through experimenting with your own dough and is a product of dough weight temperature pressing time and thickness setting 5 Swing open the lower platen and apply a quick spray of a...

Страница 5: ...soft cloth or soft sponge Never use steel wool or harsh abrasives or you will cause costly damage 2 All other exterior surfaces Here again a daily wipe down with mild soap and warm water will do the j...

Страница 6: ...ght side of the vertical post Machines with swing away upper heads have two grease ports one on the right side of the vertical post and one on the back of the vertical post All other machines have a s...

Страница 7: ...X 1 84 83 81 82 81 83 83 81 82 106 4X 78 4X 76 79 4X 71 4X 77 4X 78 4X 75 73 34 25 79 90 18 55 3X 2 4X 9 14 18 35 35 100 58 13 66 57 2X 56 4X 15 39 41 40 7 10 4X 3 44 42 43 108 11 4X 111 110 111 110 1...

Страница 8: ...36 2X A3 A4 EXPDP2300BZ RM 103118 CUSTOMER MANUAL PAGE 2 OF 3 111 112 20 26 32 98 116 113 110 115 31 118 109 126 24 37 2X 28 2X 16 27 32 33 33 32 68 4X 70 4X 69 4X 23 29 67 74 89 4X 30 92 12X 47 46 63...

Страница 9: ......

Страница 10: ...SP63214 2 27 PISTON RAM MACHINED DP2300 11023003001 11023003001 1 28 COLLAR STOP PIN DP12504 DP12504 2 29 BASE ASSEMBLY 1102300BZ1102 1102300BZ1102 1 30 COVER PLATE BASE 11054 11054 1 31 POST GUIDE D...

Страница 11: ...IC BLACK PB78P PB78P 1 89 LEG APPLIANCE 4 SATIN NICKEL FINISH AE601653 AE601653 4 90 SCREW BUTTON HEAD 1 4 20 X 5 8 SB142058 SB142058 1 91 NIPPLE BRASS 1 4 x 2 N142 N142 1 92 BOLT HEX SLOTTED 8 32 x 1...

Страница 12: ...TTED UPPER PLATEN COMPLETE ASSEMBLY 11017452374208AK 11017452374220AK 1 A3 KITTED LOWER PLATEN WITH WIRING ONLY 11017452332208K 11017452332220K 1 A4 KITTED LOWER PLATEN COMPLETE ASSEMBLY 1101745233220...

Страница 13: ......

Страница 14: ...ug unit wait for 1 min then plug machine on and depress power button ___ Digital Controller on startup goes through LED segment check 8888 then to version and then loops back to to the above reboot Th...

Страница 15: ...er the lower platen Ram casting while Press is idle The O rings are warn allowing the air to pass through the cylinder This occurs when the cylinder walls looses it s lubrication due to excessive wate...

Страница 16: ...company s products the following instructions must be adhered to First contact our customer service department for approval and a return authorization number Please have the serial number of your ite...

Отзывы: