Proluxe DEL TACO SL1266DTA Скачать руководство пользователя страница 9

DOUGHPRO

SL1266 Split Lid Grill Trouble Shooting Guide

Symptom

Probable Cause

Action to be Taken

Parts List Ref. #

Power Button on Control face is 
depressed but doesn’t turn on.

Power Cord is not plugged in.

Plug power cord into wall 's 
receptacle and depress power 
button on controller

___

Circuit Breaker is tripped off in the 
site's breaker box

Reset circuit breaker that the Grill is 
plugged into. Depress Power Button 
to turn on.

___

Transformer has taken a electrical 
surge and is damaged

Replace Transformer 

18

Check voltage on the secondary side 
of the Transformer.  If you read 
12VDC then you are receiving voltage 
to the Controller.

Replace Controller.  Controller 
should be on once the power button 
is depressed.

A8

Possibly blown Fuse

Check fuse and repace if necessary

# 98

Digital Controller's LED's are 
scrambled or randomly irratic 

Possibly a componet on the Digital 
Controller is damaged

Replace  the  Digital Controller.  

# A8

Possibly control needs to reset

While unit is on (controller lit up) 
Unplug unit, wait for 1 min. then 
plug machine on and depress power 
button.

___

Digital Controller is constantly 
Beeping

  

No heat on either on left 

right Upper, or Lower  Platen. 
Depress Temp. While depressing 
Temp., depress either up or down 
arrow to locate error 
message,"PROB" (zone 1, Lower 
Platen, zone 2 Left Upper Platen, 
zone 3, right Upper Platen.) 

.  

If 

occurred when depressing the up 
arrow indicates either the left or 
right Upper Platen has the open 
sensor or probe.  same goes for the 
down arrow indicating Lower Platen.

Sensor in one of two zones lost it's 
continuity. Depress Temp. While 
depressing Temp., depress either up 
or down arrow to locate error 
message,"PROB" (zone 1, Lower 
Platen, zone 2 Left Upper Platen, 
zone 3, right Upper Platen.) .  If 
occurred when depressing the up 
arrow indicates either the left or right 
Upper Platen has the open sensor or 
probe.  same goes for the down 
arrow indicating Lower Platen

Disconnect prob and check for 
continuity (by using Ohm Meter) and 
replace.  Do not cut and splice new 
sensor. Install new 2000 ohm RTD 
sensor to under side of Heat Platen 
and reconnect to Controller.  Upper 
left and right sensor for replacement 
on upper platens, Lower Platen 
sensor for replacement for Lower 
Platen.

# 22                                   
# 46      

Digital Controller is beeper chirping 
and is over heating.  

The Mechanical Relay on the 
switched side is not opening to 
regulate temperture.  Same as above, 
hold Temp button then depress 
either the down or up arrow (zone 1, 
Lower Platen, zone 2 Left Upper 
Platen, zone 3, right Upper Platen.) 
which ever zone is the problem, you 
will see RLY indicating the damage (in 
closed position) .

Replace the Mechanical Relay.

#15

One of the three Heater Platens not 
close to set point. 

The offset function in the Controller's 
setting needs to be adjusted to 
achieve proper shade of toast. 

Call Doughpro (800) 624-6717 for 
instructions.  This information must 
not to be given to operators of the 
SL1577.  They may get confused and 
cause further temperature 
discrepancies.

____

Beeper not functioning 

Beeper has failing.

Replace Controller board

# A8

Содержание DEL TACO SL1266DTA

Страница 1: ...rmerly DOUGHPRO New Name Same Quality Superior Service proluxe com Operations Manual Model SL1266DTA Digitally Controlled Split Lid Clam Shell Grill See Start Up Instructions on pages 2 4 rev RD 03081...

Страница 2: ...cess cleaner with damp disposable towels 8 Rinse towels and repeat until surface is completely clean 9 Season by applying a thin layer of Release agent to top and bottom surfaces and spreading it even...

Страница 3: ...down all exterior surfaces with a warm damp food handler towel with Kay QSR Multi Purpose Sink Detergent then dry 4 Scrape loose debris from heating surfaces into the grease catcher in the back right...

Страница 4: ...ation number and call tag or find the name and location of a Factory Authorized Service Center nearest to you When calling for service please furnish the model number serial number and a description o...

Страница 5: ...the power switch which will illuminate when turned on The display flashes and shows left preset timer during warm up Pre heat temperature time will be 40 50 minutes When the set point is reached the...

Страница 6: ...is turned on All preset LED s are turned off and the temperature set point is changed to the clean set point of 275 F This also initiates the cool down to clean set point condition as well the displa...

Страница 7: ...and the ARROW UP button at the same time 2 To find the temperature of the LOWER PLATENS Press the TEMPERATURE button and the ARROW DOWN button at the same time 275 is the factory default temp for the...

Страница 8: ...ton and continue to hold both for 5 seconds The digital displays will now read their preset times as shown here Each side is capable of having up to 4 different settings making a total of 8 set times...

Страница 9: ...Upper Platen has the open sensor or probe same goes for the down arrow indicating Lower Platen Sensor in one of two zones lost it s continuity Depress Temp While depressing Temp depress either up or...

Страница 10: ...ith use of a Ohm Meter a condinuity check must check at the cold pins of the heater where the heater wire is brazed at the cold pin This will eliminate any other failue before the the heater element v...

Страница 11: ...59 2X 25 2X 78 8X 76 22 2X 74 4X 72 2X 13 2X 26 2X 16 4X 42 4X 47 4X 62 2X 21 23 24 6X 28 8 52 14 2X 51 2X 43 2X 65 2X 63 4X 6 77 SL1266DTA EXPSL1266DTA RJ 100419 CUSTOMER MANUAL SHEET 1 OF 3 75 40 6...

Страница 12: ...55 DETAIL A 10X 56 2X 35 2X 33 3X 36 27 3X 39 2X 34 57 32 30 B EXPSL1266DTA RJ 100419 CUSTOMER MANUAL SHEET 2 OF 3 66 4X 49 4X 48 12X 7 2 A5 A6 37 53 4X 3X 41 3X 67 6X 44 58 DETAIL B...

Страница 13: ...52 4X 11 1 61 3X 47 3X 45 3X 68 2X 20 A2 A4 EXPSL1266DTA RJ 100419 CUSTOMER MANUAL SHEET 3 OF 3 52 4X 10 1 61 3X 47 3X 45 3X 19 68 2X A1 A3 38...

Страница 14: ...ASSEMBLY 11018344026 1 23 GREASE TRAY ASSY 11018344005 1 24 PIN PIVOT FRONT 11017088865 2 25 TOP LINK 11018344017 2 26 SPACER LINK 11018344024 2 27 SINK HEAT ALUMINUM SSR 11057322 3 28 WIRE HARNESS 11...

Страница 15: ...NG TEFLON 3 4 ID X 7 8 OD X 1 L 110115541 4 69 BUSHING FLANGED TEFLON 3 4 ID X 875 OD X 5 L 110115563 2 70 BUSHING FLANGED TEFLON 3 4 ID X 875 OD X 1 0 L PG17807 2 71 SPRING DETENT 110115555 2 72 LOW...

Страница 16: ......

Страница 17: ...ir or replacement will be at the expense of Proluxe on under the normal one year warranty WHAT WE WILL DO Contact our Factory to obtain warranty service Proluxe must issue a return authorization numbe...

Страница 18: ...pany s products the following instructions must be adhered to First contact our customer service department for approval and a return authorization number Please have the serial number of your item av...

Отзывы: