Welcome to a whole new world of air treatment from Prolitec, the technology leader in air care with scent. 
The AQ1200 appliance is the most advanced commercial air-treatment system on the market today. It is the 
world’s first fully adjustable commercial air-treatment system engineered to serve indoor spaces.

AQ1200 is a patented, computer-controlled, always-on system capable of maintaining a constant, uniform 
and controlled level of scent or odor neutralizer. 

The AQ1200 converts fragrances and odor control formulations (“Agents”) into ultra-fine droplets for 
controlled distribution as an aerosol or vapor directly into a room or via the airflow of the HVAC system, 
either through the central fan unit (CFU) or at suitable locations in the branched ductwork. It is designed for 
permanent installation on a wall in the area to be treated or integrated with the CFU.

The AQ1200 is managed by an on-board computer that is fully adjustable, enabling intensity settings to 
match space sizes from 1,800 to 150,000 cubic feet (50-4,200 cubic meters) per appliance. The AQ1200 is 
programmable, capable of executing 21 distinct start and stop times, repeatable daily or weekly. Utilizing 
up to 21 programs and the full range of 50 intensity settings allows you to optimize the fragrance levels 
depending on peak and non-peak occupancy in the space. This new feature can save you money on 
fragrance AND service visits. Multiple appliances can work together on the same or multiple CFUs to treat 
the air in the same spaces served by the HVAC. Multiple appliances can work together in the same space.

Typical AQ1200 applications include air treatment to enhance or improve indoor air quality including 
odor cancelling, and ambient scenting in public spaces such as casinos, malls, hotels, theaters, ballrooms, 
convention centers, hospitals, retirement and assisted living facilities, schools and restrooms. A single 
AQ1200 can do both odor control and ambient scenting at the same time.

The AQ1200 with Prolitec odor control formulations and fragrances will cancel a wide range of offensive 
odors and replace them with pleasant scents available from the Prolitec fragrance catalog or custom 
developed to meet client requirements.

The AQ1200 works by generating ultra fine, ultra-light droplets approximately 1 micrometer (µm) in 
diameter. By comparison, a droplet from a typical pressurized aerosol spray can is 50 microns (50000 
nanometers) in diameter or 50 times larger than an AQ1200 droplet. In terms of weight and volume of 
liquid, the comparison is even more dramatic. A 50-micron aerosol droplet is 125,000 times heavier than a 
1 µm AirQ droplet.1  (See also Table 1 below.) This tiny AirQ droplet offers many performance benefits over 
a conventional aerosol including: completely uniform distribution of the treatment agent; 50 times more 
exposed surface area; and the absence of any liquid deposits on surfaces such as the interior surfaces in an 
HVAC system.

AQ1200 is simple to install and program for specific room size, airflow conditions, and desired scent 
intensity. Minimal maintenance is required beyond the periodic change of the disposable fragrance 
cartridge, inspection and annual replacement of three O-rings, and a simple wipe down or dusting of 
exterior surfaces. Once installed in the right location, AQ1200 will outperform any other system, providing 
completely uniform scent distribution. 

The AQ1200’s advanced technology creates a scent effect with a smaller quantity of fragrance ingredients 
than any other method. The chemicals employed in making AQ1200 fragrances are fully compliant with 
the most restrictive air-quality and inhalation standards. AQ1200 generates no harmful VOCs and uses no 
ethanol or propellants. Quite simply, used as directed, AQ1200 is the greenest, most eco- friendly way to 
introduce scent into an interior space with no negative impact on indoor air quality. This is not an accident. 

1

Содержание AirQ AQ1200

Страница 1: ...by Prolitec AQ PS RZ 1200 1200 SOC Original Instructions Rev 2015 05 15...

Страница 2: ...r 7 OPERATING INSTRUCTIONS Unit Programming Setting Scent Intensity Scent Control Chapter 8 INSTALLATION Diffusion via HVAC system Installation Kit for Appliance Installation Kit for HVAC System DIffu...

Страница 3: ...s retirement and assisted living facilities schools and restrooms A single AQ1200 can do both odor control and ambient scenting at the same time The AQ1200 with Prolitec odor control formulations and...

Страница 4: ...ctly will meet the most demanding requirements Table 1 Prolitec AirQ Technology vs Aerosol Spray Can Technology Parameter Prolitec AirQ Technology Aerosol Spray Can Droplet Diameter m 1 50 Volume per...

Страница 5: ...1 5 1800 8100 51 229 6000 25000 170 708 6 10 10000 17400 283 492 30000 47100 849 1333 11 15 19300 27700 546 784 51100 66300 1446 1876 16 20 30000 39700 849 1124 70000 83600 1981 2366 21 25 42300 5340...

Страница 6: ...upper respiratory discomfort This appliance is not intended for use by persons with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supe...

Страница 7: ...ted nature of the fragrances may make the scent difficult to remove from hands and skin Wash your hands after all contact with Cartridges or fragrance While AirQ Air Treatment Agents do not contain in...

Страница 8: ...Controls Appliance Controls Hose Clamp Hose Connector Air Nozzle Recyclable Cartridge First Stage Air Filter Control Display Program Selector Control Buttons Battery Tab Injector Hose DC Power Jack s...

Страница 9: ...m the cartridge output port and pulling out 5 Remove cartridge from appliance enclosure 6 Install new cartridge place and tighten hose connector firmly on cartridge output port 7 Insert air nozzle and...

Страница 10: ...lter should be replaced To replace it unscrew the 3 knobs to open the panel and exchange the filter after pulling off the rubber tubing from both sides of the filter Note the small triangle showing th...

Страница 11: ...mmet The battery is located on the lower front corner of the silver bracket 3 Insert the new CR2032 battery The positive side of the battery should face your right while looking at the front of the ap...

Страница 12: ...ns to select the day You can set maximum of 3 on off programs same for every day or individually for each day After selecting the day press the Set button to advance Now the 1 icon is turned on to ind...

Страница 13: ...ogram and set the intensity level with the keys You will see the level numbers 1 to 50 on the right side of the screen Hint There are many variables to finding the scent level that works size airflow...

Страница 14: ...200 appliance not pictured with 2 Four 4 drywall anchors for mounting in drywall 3 Four 4 lead anchors for mounting in concrete 4 Four 4 screws and 4 washers for mounting in drywall and concrete 5 Fou...

Страница 15: ...to be targeted for air treatment 2 Determine the Air Handling Unit or duct that serves the target area 3 Make sure the AHU does not use an open gas flame 4 Find and mark the optimal insertion point fo...

Страница 16: ...er steam chilled water and DX coils Open gas flames should absolutely be avoided If installation must be over gas heated coils or open gas flames contact Prolitec Technical Support The best location f...

Страница 17: ...AC plug to the cord and connect to a nearby outlet Open the enclosure door and unscrew the aluminum cap of the waterproof collar located on top of the appliance enclosure Remove and set aside the gro...

Страница 18: ...section of duct and far away from any turns branches or cross section changes as practical and not immediately after the supply fan 1 At the insertion point drill a hole using a drill bit 2 Insert th...

Страница 19: ...uded 1 One 1 AQ1200 appliance not pictured with 2 Four 4 dry wall anchors for mounting in drywall 3 Four 4 lead anchors for mounting in concrete 4 Four 4 screws and 4 washers for mounting in drywall a...

Страница 20: ...One 1 Prolitec Diffusion fan and cable for direct indoor diffusion 2 Three 3 drywall anchors for mounting fan onto dry wall 3 Three 3 lead anchors for mounting in concrete 4 Three 3 screws for mountin...

Страница 21: ...Place the appliance onto the desired location on the wall and ensure that it is level 2 Fasten the appliance to the wall using the necessary anchors screws and washers provided 3 Open the enclosure d...

Страница 22: ...ng holes Fig 4 3 For installation on drywall drill the 3 anchors into drywall and install the 3 screws to secure the diffusion fan to the wall Use the metal screws provided for installation on sheet m...

Страница 23: ...11 If needed use a flat head screw driver to push in the side wall of the cable raceway Fig 12 Fig 13 Fig 14 7 Insert cable connector into jack located on the right side of the appliance Fig 12 8 Ext...

Страница 24: ...ace Increase the output rate by one or two settings and evaluate detection in 30 minutes Repeat as needed If consumption requires cartridge change more frequently than each month install an additional...

Страница 25: ...t tube Check and remove it The air intake may be blocked Another method for clearing obstructions is while the appliance compressor is running block the output tube with a finger for a few seconds and...

Страница 26: ...ot paint or otherwise try to alter the color of the outer cover Always keep the cap and plug on cartridges when stored outside of the AQ1200 Do not operate AQ1200 in very dusty areas that may cause th...

Страница 27: ...C at 0 6A Frequency 50 60 Hz Protection Switching power supply Internal Power 12V DC at 1 5 A Battery Lithium 3V CR2032 Approvals UL CSA listed Power Supply Working Temperature 0 to 40 C Working Humid...

Отзывы: