Applications

The Prolitec approach to odor remediation uses a proprietary and patented neutralizer that inhibits 
the human olfactory system from detecting the odor and then injecting a small amount of scent to 
create an ultra-low concentration in the air of less than 1 ppm. This approach is unique and much 
more effective than traditional approaches that simply douse the odor with a high concentration of 
scent. 

Aromatherapy and Performance Scenting

It is well known that scent has a powerful impact on human emotion and behavior. The use of 
scent to influence human emotion is just like Ambient Scenting but with a specific objective for the 
occupants of the treated space. The use of scent and the essential oils of flowers, herbs and trees 
to promote health and well being is the well-established branch of alternative medicine known as 
aromatherapy. It is also recognized that scent can be used to optimize performance in the workplace. 
The benefits include reduced errors in routine functions, increased employee sense of well being, 
higher morale, improved customer service and overall improved productivity.

AirQ 1280 and Prolitec aromatherapy chemistry can help make a workspace a more comfortable and 
appealing place to be. As examples of the positive effect of aromatherapy on the workplace, below 
are results of several relevant studies:

•  A 1991 study demonstrated that “sustained attention tasks” were performed with greater 

accuracy by the participants in scented rooms compared to those in the non-scented control 
rooms.

1

•  Another study found that fragrance had a dramatic and positive effect on a proofreader’s 

efficiency.

2

•  It is commonly known that the Tokyo Stock Exchange diffuses peppermint into the air in the 

afternoons to make the brokers feel invigorated.

_______________

1

 Dr. Joel Warm and Dr. William Dembar. “Olfactory Stimulation and Sustained Attention.” 

Compendium 

of Olfactory Research

, (Dubuque, Iowa: Kendall/Hunt Publishing Co., 1995) p. 47.

2

 Mark Kilauga et al. “Consumer Panel Study on the Effect of Peppermint and Lavender Fragrances on 

Proofreading.” 

Compendium of Olfactory Research

, (Dubuque, Iowa: Kendall/Hunt Publishing Co., 1995) 

p. 131

14

Содержание AirQ 1280

Страница 1: ...AirQ 1280 PERFECTLY SCENTED ENVIRONMENTS Original Instructions Rev 2019 07 01 ...

Страница 2: ...on via HVAC system Installation Kit for Appliance HVAC Pre installation Checklist Appliance Positioning AirQ Injection Locations Appliance Installation Universal HVAC Kit Installation Installation Kit for HVAC System Diffusion Installation Kit for HVAC Sensor HVAC Sensor Installation Chapter 10 INSTALLATION Diffusion via Direct Indoor Fan Installation Kit for Fan Pre installation Checklist Applian...

Страница 3: ...ncluding watery eyes headache cough and upper respiratory discomfort This appliance is not intended for use by persons with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety 2 INSTRUCTIONS PERTAINING TO A RISK OF FIRE ELECTRIC SHOCK OR IN...

Страница 4: ...ference and 2 this device must accept any interference received including interference that may cause undesired operation NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generat...

Страница 5: ... scenting in public spaces such as casinos malls hotels theaters ballrooms convention centers hospitals retirement and assisted living facilities schools and restrooms A single AirQ 1280 can do both odor control and ambient scenting at the same time The AirQ 1280 with Prolitec odor control formulations and fragrances will cancel a wide range of offensive odors and replace them with pleasant scents...

Страница 6: ...sy to read It is also important to read AirQ 1280 is a high performance appliance that installed and used correctly will meet the most demanding requirements Table 1 Prolitec AirQ Technology vs Aerosol Spray Can Technology Parameter Prolitec AirQ Technology Aerosol Spray Can Droplet Diameter µm 1 50 Volume per Droplet µm3 0 52 65 450 Surface Area per Droplet µm2 3 7 854 Relative Volume per Droplet...

Страница 7: ...The following items should be included 1 AirQ 1280 Appliance 2 HVAC kit 3 Plume kit 4 AC Cord 5 Mounting Hardware MOVING AND STORAGE INSTRUCTIONS 1 Remove the cartridge 2 Unplug the appliance 3 Disconnect the appliance from the tubing bulkhead etc 4 Store at 4 F 20 C to 158 F 70 C 5 to 95 humidity 3 4 ...

Страница 8: ...333 75000 97100 2123 2748 11 15 19300 27700 546 784 51100 66300 1446 1876 101100 114000 2861 3226 16 20 30000 39700 849 1124 70000 83600 1981 2366 116700 125100 3303 3540 21 25 42300 53400 1197 1511 86800 98900 2456 2799 126900 132800 3591 3758 26 30 56300 68600 1593 1941 101600 112800 2875 3170 134000 138300 3792 3914 31 35 71800 812800 2032 2425 114400 123500 3238 3495 139200 142400 3939 4030 36...

Страница 9: ...AirQ 1280 9 Appliance Controls Appliance Controls 6 Plume Kit Air Stem Recyclable Cartridge Programming USB Port Control Display Control Buttons ScenXus Connector AC Inlet ...

Страница 10: ...and pulling 4 Detach plume kit from the cartridge output port located on the top of the cartridge head This is done by unscrewing the cap from the cartridge output port and pulling out 5 Remove cartridge from appliance enclosure 6 Install new cartridge place and tighten plume kit firmly on cartridge output port 7 Insert air nozzle and rotate the handle 90 degrees until secured by stem retaining ta...

Страница 11: ...on use A layer of black dust on top of the filtering media is a sign that the filter should be replaced To replace it unscrew the four screws to remove the bracket and exchange the filter after pulling it off the rubber tubing Note the small triangle showing the normal air flow direction and position filter accordingly as shown below The check valve PN 10200 should be replaced every six months It ...

Страница 12: ...es using E or F Press L to set the time mode and the off cycle will blink Change between normal NOC 7 minutes short SOC 2 minutes and very short VSOC 30 seconds modes using E or F Press L to set the off cycle and the fan setting will blink Adjust the fan speed up or down using E or F Press L to set the fan speed and the day of the week will blink 4 24 7 Mode If you want AirQ 1280 to run continuous...

Страница 13: ...ess L to set the stop hour and the minute will blink Adjust the stop minute forward or backward using E or F Press L to set the step minute The appliance will automatically switch from set program to run program after 30 seconds of inactivity or you can press I until SET PROGRAM is displayed above the time You may review the programs by pressing L while the appliance is in run program mode Using t...

Страница 14: ...Insert a USB stick Copy the files needed schedule txt for programs firmware bin for firmware to the top level directory of the USB stick not in a folder or zip file 6 Insert the USB stick into the appliance Loading new firmware from a USB stick 1 Copy firmware bin to a USB stick 2 Insert the USB stick 3 Press the reset button and the five buttons will light in sequence from left to right 4 The and...

Страница 15: ... view the second and third programs 13 Be sure the power is on and the appliance is in RUN PROGRAM mode prior to closing and locking the door Copying programs to a USB stick 1 Insert a USB stick 2 Press the reset button and the five buttons will light in sequence from left to right 3 The and E buttons will light alternately 4 Press and hold E for one second and the display will show SAVE for about...

Страница 16: ...l user preferences Experiment with different levels until you are satisfied Utilize the S4 Tool Scent Control If you followed the Room Size Table or S4 Tool you have set AirQ 1280 to the low end of the range for your room size If after one hour you feel the scent is not detectable increase the setting by about 10 For example if your start setting was 20 increase it by 10 or to setting 22 Keep incr...

Страница 17: ... Installation Kit for Appliance included 1 One 1 AirQ 1280 appliance not pictured with 2 Eight 8 10 self tapping sheet metal screws for mounting in sheet metal 3 Plume connector A 1 Tubing B 1 Bulkhead Connector C 2 Washers D 1 Nut E 3 Cable Ties F 2 O Rings G Cartridge Connector H Cap 3 E D C B A 2 F G H 9 ...

Страница 18: ... location NEVER MORE THAN 3 FEET and there should NEVER be a LOW POINT in the hose run 7 Determine and mark the location for the 110 or 220V AC power outlet NEVER DIRECTLY BELOW THE appliance Appliance Positioning It is important to find an insertion point where the plume output will be smoothly drawn into and mixed with the airflow On larger AHU s it may be practical to mount the whole appliance ...

Страница 19: ...rQ AHU and Duct Injection Locations PREFERRED AVOID 1 2 3 4 AirQ HVAC and Duct Injection Locations PREFERRED AVOID 1 2 3 4 CONDITIONED AIR TO ROOMS GAS FURNACE GAS LINE FURNACE AIR EXHAUST A C EVAPORATOR COIL CONDENSATE DRAINS RETURN AIR DUCT AIR FILTER 9 ...

Страница 20: ...be Fig A The injector hose should be run upward as short a distance as possible and NEVER MORE THAN 3 FEET If an upward injector hose run is not possible care should be taken support the hose to prevent sagging or any low spot in the run to avoid any possibility of condensation and liquid collection which will block the plume output The injector hose is prone to stretching so support points should...

Страница 21: ... using necessary screws 3 Attach an AC cord and connect to a nearby outlet 4 Assemble the plume connector Assembling the Plume Connector Roll O rings into grooves Fig 1 Insert assembly into cap barbed end first so that threads of cap cover O rings Fig 2 Push tube over barbed end of cap assembly Fig 3 Push tube over barbed end of bulkhead fitting Fig 4 Tightly secure tube in position with ZipTies F...

Страница 22: ...om the interior of the appliance fit the exposed threaded end of the assembly through the hole in the TOP of the cabinet Fig 8 Fig 9 Apply gasket over exposed threaded portion of the assembly Fig 10 Firmly tighten nut in place to create a water tight installation Fig 11 Fig 8 Fig 9 Fig 10 Fig 11 9 ...

Страница 23: ...a C SELF DRILLING SCREW 2 ea D SET SCREW 1 ea E ZIP TIE colors may vary 2 ea F INJECTOR MOUNT 2 ea G CARTRIDGE ADAPTER 1 ea H SENSOR COVER 1 ea Note not all parts are used in all installations B C A D E F G H AA BB CC DD EE KITHVACSENSOR Optional accessory sold separately adds these COMPONENTS AA ADAPTER TUBING 1 BB SENSOR CABLE 1 ea CC SELF DRILLING SCREW 2 ea DD SET SCREW 1 ea EE SENSOR 1 ea 9 ...

Страница 24: ...ed Tools 1 3 8 Electric Drill 2 Step Drill Bit 1 8 1 2 capacity 3 2 Phillips Screwdriver 4 2 Phillips Screwdriver Bit for use with Electric Drill 5 Tubing Cutter w Deburring Tool capacity to cut 3 8 Aluminum tube 6 Diagonal Cutter 7 Torpedo Level 8 Tape Measure 9 ...

Страница 25: ...installation before proceeding Using a step drill drill a hole into the HVAC system to create an injection port that is slightly larger than 3 8 diameter 2 Confirm the hole size is large enough using the Aluminum tube Enlarge the hole as necessary While securely holding the Aluminum tube check the fit to the hole it should pass freely into the injection port with a minimum gap 9 ...

Страница 26: ...is time 4 Insert the Aluminum tube into the center hole of the injector mount as shown Using a tape measure set the length to reach to the center of the duct or leave at least 1 of tube exposed as shown Gently hand tighten the set screw as needed to positively maintain the position of the Aluminum tube 1 Minimum 2 Philips Screwdriver Center of Duct Outside of Duct 9 ...

Страница 27: ...ecessary cut off any excess Aluminum tubing using a tubing cutter Cut the Aluminum tube to ensure that 1 of tube is left exposed 1 6 If you cut the tube deburr the Inside Diameter ID of the Aluminum tube then clean out any debris from the inside of the tube 9 ...

Страница 28: ... it meets the duct While using a level ensure that the UP arrows are pointing vertically up in both planes as shown Note the vertical orientation of these planes is important to help prevent condensation from draining into the HVAC system 8 Mark the 2 mounting holes that you will use to mount the injection assembly 9 ...

Страница 29: ...tem 9 Remove the injection assembly and pilot drill the marked mounting holes with a 1 8 diameter drill 10 Attach the injection assembly to the duct with the top self drilling screw tightening it to hold the injection assembly in position as needed 9 ...

Страница 30: ... system with the second self drilling screw tightening both the screws as necessary to secure the assembly to the HVAC system while maintaining the vertical orientation set forth previously 12 Attach the injector tubing to the injection assembly fully covering the exposed Aluminum tube as shown 9 ...

Страница 31: ... DIffusion via HVAC System 13 Secure the tube with a zip tie at the midpoint of the Aluminum tube Tighten the zip tie as needed to secure the tubing in place 14 Cut off the excess zip tie to complete the injector installation 9 ...

Страница 32: ...AC System 15 Cut tube to the desired length and connect to the appliance 16 Secure the tube with a zip tie as shown Tighten the zip tie as needed to secure the tubing in place 17 Cut off the excess zip tie to complete the appliance connection 9 ...

Страница 33: ...s installation AND the provided sensor cable can connect to the appliance before proceeding Using a step drill drill a hole into the HVAC system to create a sensing port that is 1 2 diameter 2 To create the sensor mounting assembly fully thread the set screw by hand into the injector mount from the KITHVAC until the head contacts the mount red arrow Then unthread the screw until it is clear of the...

Страница 34: ...ION DIffusion via HVAC System 3 Align the center hole of the mount with the sensing port Ensure that the UP arrows are pointing vertically up and mark the two holes shown 4 Drill the marked holes with a 1 8 diameter drill 9 ...

Страница 35: ...unting assembly to the HVAC system with 2 self drilling screws tightening both the screws as necessary to secure the mount assembly to the HVAC system 6 Attach the terminals of the sensor cable to the tabs on the terminal side of the sensor as shown Terminal Side Back Side 9 ...

Страница 36: ...l side of the sensor guide the sensor cable into the slot of the sensor cover from the KITHVAC as shown green arrow Align the cover of the sensor over the port as shown red arrow then snap the cover fully into place 8 Push the adapter tube over the sensor port as shown 9 ...

Страница 37: ...tly guide the adapter tube portion of the sensor assembly fully into the mount as shown 10 Use a level to ensure that the surface marked THIS SURFACE MUST REMAIN VERTICAL is vertical Note if this surface is not vertical the sensor can give a false ON signal 9 ...

Страница 38: ...N THIS STEP AS IT WILL DAMAGE THE SENSOR While maintaining the vertical orientation GENTLY HAND TIGHTEN the set screw just enough to compress the adapter tube and hold the sensor in place completing the sensor installation 2 Phillips Screwdriver 12 Remove the access plug from the appliance 9 ...

Страница 39: ...AirQ 1280 39 INSTALLATION DIffusion via HVAC System 13 Remove the HVAC JUMPER plug 14 Connect the HVAC SENSOR CABLE as shown to complete the appliance connection 9 ...

Страница 40: ... Kit for Fan accessory sold separately 1 One 1 Prolitec Diffusion fan and cable for direct indoor diffusion 2 Three 3 drywall anchors for mounting fan onto dry wall 3 Three 3 screws for mounting in drywall and concrete 4 Five 5 feet of small cable raceway for fan cable 5 Three 3 feet of OD injector hose 1 3 4 5 2 10 ...

Страница 41: ...he Appliance requires 110 220V AC Appliance Positioning It is important to find a location that is easily accessible for service and cartridge refills Appliance Installation 1 Place the appliance onto the desired location on the wall and ensure that it is level 2 Fasten the appliance to the wall using the necessary anchors screws and washers provided 3 Assemble the Plume Connector see instructions...

Страница 42: ...es Fig 4 3 For installation on drywall drill the 3 anchors into drywall and install the 3 screws to secure the diffusion fan to the wall Use the metal screws provided for installation on sheet metal or appropriate fastening hardware for other wall surfaces Figs 5 6 4 Verify cable connection with diffusion fan Fig 7 5 Measure the length of cable raceway needed and cut to length using a pair of scis...

Страница 43: ...iver to push in the side wall of the cable raceway Fig 12A Fig 12B Fig 13 Fig 14 7 Remove plug Fig 12A 8 Thread cord through access hole and insert cable connector into jack located on the face of the appliance Fig 12B 9 Extend the hose from appliance toward the diffusion fan hose barb cut to proper length Fig 13 and secure to the hose barb of the diffusion fan assembly Fig 14 10 Turn the APPLIANC...

Страница 44: ...em 1 Unpack the appliance as normal but do not plug it in yet 2 Remove the extra labels from the ScenXus module 3 Adhere the remaining ScenXus label inside the appliance door adjacent to the serial number and take a photograph 4 Attach the ScenXus module to the appliance by pressing the connector into place 11 ...

Страница 45: ... 5 While remaining in the approximate installation location of the appliance open settings on your smart phone and locate Wi Fi settings 6 Under Wi Fi settings make sure you see the network that will provide ScenXus internet access 11 ...

Страница 46: ...liance normally with ScenXus still attached next to the DC jack 8 Power on the appliance and look for the firmware on the display 9 The network icon will blink 10 Refresh the list of Wi Fi networks on the phone until you see a network titled ScenXus 11 ...

Страница 47: ... IP address 192 168 0 1 to see the list of networks 12 Connect to the network that will provide ScenXus with internet access 13 Type in the password for your wireless router 14 Wait as your smart phone disconnects from ScenXus ScenXus connects to the router and the router connects to the internet When ScenXus is connected to the cloud you ll see the message connection complete 15 The network icon ...

Страница 48: ... ayla aylanetworks com that gives you a token to confirm your account Be sure to check your junk and spam folders 2 On your iPad or Laptop go to scenxus com and sign in using your email address and the aforementioned token 3 Depending on your account you will see a slightly different version of this homepage 11 ...

Страница 49: ...ce cartridge and install location 5 Go to the Monitor Control page and adjust the appliance options and settings as needed 6 For complex programming navigate to the SD card programming tool on airqtools com and download the schedule txt file to your laptop 7 Upload the schedule txt file to the appliance via the Monitor Control page at scenxus com 11 ...

Страница 50: ...close down your browser not just the tab re launch the browser and log in again Internet Explorer relies heavily on cached data meaning that changes may have been sent to the cloud but your browser may still show old values There are settings to prevent this behavior and other browsers Chrome Firefox Safari Edge etc do not have this issue 11 ...

Страница 51: ...l an additional appliance The O Rings on the stem that fits into the head may be worn out and causing an air leak Replace the O Rings by removing the worn one with a pointy tool and rolling on the new ones Fragrance intensity is stronger than just detectable The output rate is too high Lower the output rate in increments of one or two settings or down to the starting rates suggested in the room si...

Страница 52: ...Check and remove it The air intake may be blocked Another method for clearing obstructions is while the appliance compressor is running block the output tube with a finger for a few seconds and then open it by removing your finger The O Rings on the stem that fits into the head may be worn out and causing an air leak Replace the O Rings by removing the worn one with a pointed tool and rolling on t...

Страница 53: ... or otherwise try to alter the color of the outer cover Always keep the cap and plug on cartridges when stored outside of the AirQ 1280 Do not operate AirQ 1280 in very dusty areas that may cause the air intake to clog Do not move or transport an appliance with a cartridge installed Please call Prolitec Customer Service at 844 247 7599 for return shipping instructions or questions 13 ...

Страница 54: ...ll as auditory elements like music With ambient scenting a carefully selected fragrance is used to enhance themes animate visuals make a tree or a flower smell like a tree or a flower and many other uses Major brands are using scent to extend and animate their brand by associating a scent experience with a brand like a hotel chain using ambient scenting to make all their lobbies smell like the sam...

Страница 55: ...s associate intervention Billboards and advertising panels can be equipped with AirQ 1280 to treat the surrounding air space with the scent that is being advertised on the billboard This is particularly effective in high traffic areas such as malls airports and train and subway stations This is a multi sensorial approach that draws customers to the display while simultaneously enhancing the visual...

Страница 56: ...d errors in routine functions increased employee sense of well being higher morale improved customer service and overall improved productivity AirQ 1280 and Prolitec aromatherapy chemistry can help make a workspace a more comfortable and appealing place to be As examples of the positive effect of aromatherapy on the workplace below are results of several relevant studies A 1991 study demonstrated ...

Страница 57: ...le top Do I need to adjust AirQ 1280 Yes AirQ 1280 is a powerful machine AirQ 1280 can handle small and very large rooms If it is set too high for the room size it can cause discomfort for some people Adjusting is simple Take the time to do it right How do I adjust AirQ 1280 With the power cord plugged in you can adjust AirQ 1280 up and down using the E and F buttons just to the right of the LCD s...

Страница 58: ...ike many air fresheners AirQ 1280 uses no ethanol or similar solvents to enhance the evaporation of fragrance chemicals I only want to scent the room at certain times Do I have to turn it on and off every time AirQ 1280 has a tiny on board computer for fully automatic operations You can set set up to 21 separate start and stop times See Unit Programming If I want a different scent can I switch car...

Страница 59: ... 0 6A Max Frequency 50 60 Hz Protection Class 2 power supply Internal Power 15V DC at 1 2 A Battery Internal backup battery Approvals FCC part 15 CE RoHS Listed Separate Working Temperature 0 to 40 C Working Humidity 85 or less Liquid Capacity 1250mL or 2500mL cartridges Service Area Up to 150 000 cu ft 4245 m3 served Prolitec Incorporated 1235 W Canal Street Milwaukee WI 53223 1 844 247 7599 www ...