VI.

 

Installation

 

 

A.

 

Pre

installation

 

Checklist

 

This

 

checklist

 

should

 

be

 

completed

 

before

 

the

 

install

 

date.

  

1.

 

Confirm

 

the

 

area

 

to

 

be

 

targeted

 

for

 

air

 

treatment

 

2.

 

Determine

 

the

 

Air

 

Handling

 

Unit

 

or

 

duct

 

that

 

serves

 

the

 

target

 

area.

  

3.

 

Make

 

sure

 

the

 

AHU

 

does

 

not

 

use

 

an

 

open

 

gas

 

flame.

  

4.

 

Find

 

and

 

mark

 

the

 

optimal

 

insertion

 

point

 

for

 

the

 

Injector

 

Tube.

 

(See

 

section

 

C:

 

Appliance

 

Positioning

”)

 

5.

 

Find

 

and

 

mark

 

the

 

exact

 

location

 

for

 

placement

 

of

 

the

 

appliance

 

(See

 

section

 

C:

 

Appliance

 

Positioning

”)

 

6.

 

Note

 

the

 

distance

 

between

 

the

 

insertion

 

point

 

and

 

the

 

proposed

 

appliance

 

location.

 

(NEVER

 

MORE

 

THAN

 

6

 

FEET)

 

and

 

there

 

should

 

NEVER

 

be

 

a

 

LOW

 

POINT

 

in

 

the

 

hose

 

run.

  

7.

 

Determine

 

and

 

mark

 

the

 

location

 

for

 

the

 

110

 

or

 

220V

 

AC

 

power

 

outlet.

 

(NEVER

 

DIRECTLY

 

BELOW

 

THE

 

appliance)

 

 

B.

 

Installation

 

Kit

 

(photos

 

 

Page

 

10)

 

• 

One

 

(1)

 

Air

Q

 

1100

 

appliance

 

(not

 

pictured)

 

• 

One

 

(1)

 

Prolitec

 

Injector

 

Tube

   

(a)

 

• 

Three

 

(3)

 

Feet

 

3/8

th

 

ID,

 

½

 

OD

 

Injector

 

hose

 

(b)

 

• 

One

 

(1)

 

hose

 

connector

 

assembly

 

(c)

 

• 

One

 

(1)

 

hose

 

clamp

 

(d)

  

• 

Seven

 

(7)

 

#10

 

self

tapping

 

sheet

 

metal

 

screws

 

for

 

securing

 

the

 

appliance

 

and

 

injector

 

tube

 

on

 

sheet

 

metal.

  

(e)

 

• 

1

 

spare

 

set

 

of

 

3

 

o

rings

 

for

 

the

 

air

 

the

 

nozzle

 

(f)

 

Содержание Air-Q 1100

Страница 1: ...Page 1 of 18 Air Q 1100 User Guide Rev 1 0 5 13 09 2009 Prolitec Inc...

Страница 2: ...utions B Fragrance Precautions III Appliance and Controls 4 IV General Maintenance 5 A Changing the Cartridge B O ring replacement C Battery Replacement V Commissioning Air Q 1100 7 A Unit Programming...

Страница 3: ...1100 applications include air treatment for odor remediation scent branding and ambient scenting in public spaces such as casinos malls hotels theaters ballrooms convention centers hospitals and restr...

Страница 4: ...osol droplet The Air Q droplet is 1 1 000 000th the weight of an aerosol droplet This means the droplets behave as if they were dry do not leave any residue on the blades or interior duct surfaces and...

Страница 5: ...wer the appliance Unplug before cleaning B Air Q Cartridge Precautions Read the Product Safety Information Sheet and the Material Safety Data Sheet enclosed provided with each shipment of Cartridges I...

Страница 6: ...f 18 rev 1 0 5 13 09 Copyright 2009 Prolitec Inc III Appliance and Controls Air Q 1100 Cartridge Injector Hose Control Display Control Buttons Power Cord Program Selector Battery Tab Air Nozzle Hose C...

Страница 7: ...ge output port 5 Insert air nozzle and rotate the handle 90 degrees until secured by stem retaining tab on cartridge head See Picture 2 6 Turn appliance on Verify that the plume is not escaping inside...

Страница 8: ...e door to access the enclosure 2 Using a pair of tweezers or needle nose pliers remove battery from the center opening of the oval grommet The grommet is located on the front of the blue bracket below...

Страница 9: ...er right side of the time digits Hold to fast forward 4 Using the 24 7 Mode If you want the Air Q 1100 to run continuously 7 days a week 24 hours a day turn the dial to 24 7 If not skip to Step 5 5 Se...

Страница 10: ...0 91 000 1 900 2 600 26 thru 30 91 000 117 000 2 600 3 300 31 thru 35 117 000 146 000 3 300 4 100 36 thru 40 146 000 177 000 4 100 5 000 41thru 45 177 000 214 000 5 000 6 000 46 thru 50 214 000 250 00...

Страница 11: ...ion for placement of the appliance See section C Appliance Positioning 6 Note the distance between the insertion point and the proposed appliance location NEVER MORE THAN 6 FEET and there should NEVER...

Страница 12: ...Guide Page 10 of 18 rev 1 0 5 13 09 Copyright 2009 Prolitec Inc Optional One hose quick disconnect fitting with 3 feet hose extension with hose clamps to increase distance up to 6 feet see note 6 abo...

Страница 13: ...hilled water and DX coils Open gas flames should absolutely be avoided If installation must be over gas heated coils or open gas flames contact Prolitec Technical Support The best location for the App...

Страница 14: ...ct to a nearby outlet 4 Open the enclosure door and unscrew the aluminum cap of the waterproof collar located on top of the appliance enclosure Remove and set aside the grommet see photo on Page 13 5...

Страница 15: ...inside of the grommet if needed to allow the Injector hose to easily slide through Leave approximately 2 inches of hose length inside the appliance to provide enough play when replacing the cartridge...

Страница 16: ...in a straight section of duct and far away from any turns branches or cross section changes as practical and not immediately after the supply fan 1 At the insertion point drill a hole using a drill bi...

Страница 17: ...ith a pointy tool and rolling on the new ones Fragrance intensity is stronger than just detectable The output rate is too high Lower the output rate in increments of one or two settings or down to the...

Страница 18: ...the worn one with a pointy tool and rolling on the new ones You detect the fragrance when entering the room but after a while you no longer notice it This is called olfactory adaptation and is normal...

Страница 19: ...tions must be outside these ranges contact Prolitec Safety and Support Hotline at 888 615 9282 Do not drop Air Q 1100 on the floor Do not drop it in or position it near an open basin of water Do not p...

Страница 20: ...Frequency 50 60 Hz Protection Switching power supply Internal Power 12 VDC at 1 5 A Back up battery Lithium 3V CR2032 Performance Up to 250 000 cu feet 7 080 cu meters subject to air flow conditions C...

Отзывы: