3. Product Overview
Front View:
Top View:
India Type
Universal Type
South Africa Type
Schuko Type
Back View:
Mounting the unit
The unit can be mounted to a wall surface. Please follow below steps:
1. Turn off the unit before mounting.
2. Select an appropriate mounting location. Use a horizontal line and the length of the line
must be 222 mm and mark the two ends on the wall. (see chart 1)
3. Drill two marks by screws.
4. Mount the unit by positioning the key-hole slots over the mounting screws. (see chart 2)
Wall
Chart 1
Chart 2
CAUTION!
Do not disassemble the inverter. Contact with the qualified service center when
service or repair is required.
WARNING!
Provide ventilation to outdoors from the battery compartment. The battery
enclosure should be designed to prevent accumulation and concentration of hydrogen gas at
the top of the compartment.
CAUTION!
Use insulated tools to reduce the chance of short-circuit when installing or working
with the inverter, the batteries, or other equipments attached to this unit.
CAUTION!
For battery installation and maintenance, read the battery manufacturer's
installation and maintenance instructions prior to operating.
Personnel Precaution -
CAUTION!
Careful to reduce the risk or dropping a metal tool on the batteries. It could spark
or short circuit the batteries and could cause an explosion.
CAUTION!
Remove personal metal items such as rings, bracelets, necklaces, and watches
when working with batteries. Batteries can produce a short circuit current high enough to
make metal melt, and could cause severe burns.
CAUTION!
Avoid touching eyes while working near batteries.
CAUTION!
Have plenty of fresh water and soap nearby in case battery acid contacts skin,
clothing, or eyes.
CAUTION!
NEVER smoke or allow a spark or flame in vicinity of a battery.
CAUTION!
If a remote or automatic generator start system is used, disable the automatic
starting circuit or disconnect the generator to prevent accident during servicing.
4. Specifications
MODEL
450
CAPACITY
450 W
INPUT
Voltage
220/230/240 VAC
Voltage Range
162-290 VAC (UPS mode)
90-280 VAC (INV. Mode)
OUTPUT
Voltage Regulation (Batt. Mode)
+/-10%
Transfer Time
10 ms typical
Waveform
Simulated Sine Wave
BATTERY
Battery Voltage
12 VDC
Floating Charge Voltage
13.4DC ±0.25 VDC
Maximum Charge Current
10 A
SOLAR CHARGER
Charging Current
10 A
System Voltage
12 VDC
PHYSICAL
Dimension (DxWxH) mm
293 X 231.5 X 82.5
Net Weight (kgs)
2.35
Power Switch
Status indicators
(please see the Operation section for the details)
Output receptacles
Operation mode selector
AC input
Input breaker
External battery connectors
Solar panel terminal
Solar charging indicator
connection