10-2. Examination & Troubleshooting
10-2-1. Display nothing
Troubleshooting:
10-2-2. No water inletting
Troubleshooting:
Measure the power supply ,is it exists
220V-240V AC voltage
?
Y
Repair power supply
N
Press the power switch
N
Check if power plug exists 220V-240V
AC voltage at the import pin
Is the tap shut off or the water pressure
too low?
Y
Open tap or wait for normal water
pressure
N
Check if water is leaking from washer
connection, especially between inlet pipe
and tap. to make sure of no bends.
Reconnect inlet pipe.
N
Check if filter of electromagnetic valve
is jammed
Clean filter
Choose pre-wash program and start
,
then check if there is 220-240V at
export pin of electromagnetic valve
Is power switch on?
Y
Y
N
Insert the plug well and test
N
Press power switch and check the
voltage between two pins of power
switch. Is there 220-240V AC
voltage?
N
Make sure power supply cable
assembly is connected well and then
replace power switch.
Cut off power and check if plugs are
connected well by pulling the plug of
PCB
.
Y
N
Y
Replace PCB
Y
Choose pre-wash program and start
,
Check if there is 220-240V at import
pin of electromagnetic valve
Is there open circuit between
electromagnetic valve and PCB?
Y
N
Replace electromagnetic valve
Reconnect the wire
Replace PCB
N
N
Y
Содержание PFL1165W-U
Страница 8: ...SERVICE MANUL PFL1165W U Chapter 3 Matters needing attention 3 1 Safety...
Страница 9: ...SERVICE MANUL PFL1165W U 3 2 During Use...
Страница 11: ...SERVICE MANUL PFL1165W U...
Страница 12: ...SERVICE MANUL PFL1165W U Chapter 5 Program Introduction 90 90...
Страница 14: ...SERVICE MANUL PFL1165W U Chapter 7 Appearance brief introduction 7 1 Name of parts...
Страница 27: ...SERVICE MANUL PFL1165W U Chapter 11 Maintenance...
Страница 28: ...SERVICE MANUL PFL1165W U...
Страница 29: ...SERVICE MANUL PFL1165W U Sincere Forever...