background image

PROLIGHTS - StudioCob  

PFC2

20

13 - MAINTENANCE

MAINTENANCE AND CLEANING THE PRODUCT

WARNING: Disconnect from the mains before starting any maintenance work

It is recommended to clean the front at regular intervals, from impurities caused by dust, smoke, or 

other particles to ensure that the light is radiated at maximum brightness.

• 

For cleaning, disconnect the main plug from the socket. Use a soft, clean cloth moistened with a 

mild detergent. Then carefully wipe the part dry. For cleaning other housing parts use only a soft, 

clean cloth. Never use a liquid, it might penetrate the unit and cause damage to it.

•  The user must clean the product periodically to maintain optimum performance and cooling. The 

user may also upload firmware (product software) to the fixture via the DMX signal input port or USB 

port using firmware and instructions from PROLIGHTS.

•  The frequency of such maintenance operations is to be performed according to various factors, such 

as the amount of the use and the condition of the installation environment (air humidity, presence 

of dust, salinity, etc.). It is recommended that the product is subject to annual service by a qualified 

technician for special maintenance involving at least the following procedures:

•  General cleaning of internal parts.

• 

For all the parts subject to friction, using lubricants specifically supplied by PROLIGHTS.

•  General visual check of the internal components, cabling, mechanical parts, etc.

•  Electrical, photometric and functional checks; eventual repairs.

•  Cleaning the lenses. Only use neutral soap and water to clean the lenses, then dry it carefully with 

a soft, non-abrasive cloth.

WARNING: the use of alcohol or any other detergent could damage the lenses.

•  All other service operations on the product must be carried out by PROLIGHTS, its approved service 

agents or trained and qualified personnel.

•  It is PROLIGHTS policy to apply the strictest possible calibration procedures and use the best quality 

materials available to ensure optimum performance and the longest possible component lifetimes. 

However, optical components are subject to wear and tear over the life of the product, resulting 

in gradual changes in colours over many thousands of hours of use. The extent of wear and tear 

depends heavily on operating conditions and environment, so it is impossible to specify precisely 

whether and to what extent performance will be affected. However, you may eventually need to re

-

place optical components if their characteristics are affected by wear and tear after an extended pe

-

riod of use and if you require fixtures to perform within very precise optical and colour parameters.

• 

Do not apply filters, lenses or other materials on lenses or other optical components. Use only ac-

cessories approved by PROLIGHTS.

VISUAL CHECK OF PRODUCT HOUSING

•  The parts of the product cover/housing should be checked for eventual damages and breaking 

start at least every two months. In addition, especially the parts of the front lens holder have to be 

checked mechanically (by means of movement by the part) if it is firmly fastened to the fixture. If 

hint of a crack is found on some plastic part, do not use the product until the damaged part will be 

replaced.

•  Cracks or another damages of the cover/housing parts can be caused by the product transportation 

or manipulation and also ageing process may influence materials.

• 

This checking is necessary for both fixed installations and preparing product for renting. Any free 

moving parts inside of the product, cracked cover/housing or any part of front lens not sitting prop

-

erly in place need to be immediately replaced.

Содержание StudioCob PFC2

Страница 1: ...USER MANUAL English version StudioCob PFC2 150W IP65 rated full colour COB LED Par REV 01 09 21...

Страница 2: ...conomic loss or any other loss occasioned by the use of inability to use or reliance on the information contained in this document Product user manual can be downloaded from the website www prolights...

Страница 3: ...LINE 09 INSTRUCTIONS FOR A RELIABLE DMX CONNECTION 09 CONNECTION DAISY CHAIN 09 CONNECTION OF THE DMX LINE 09 CONSTRUCTION OF THE DMX TERMINATION 10 DMX ADDRESSING 10 8 CONTROL PANEL 11 DISPLAY AND B...

Страница 4: ...ments of all connected devices Isolate the fixture from power immediately if the power plug or any seal cover cable or other components are damaged defective deformed or showing signs of overheating D...

Страница 5: ...ace of the fixture can reach up to 60 C 140 F during operation Avoid contact with people and materials Maintenance Warning Disconnect the fixture from AC mains power and allow to cool for at least 10...

Страница 6: ...electrical equipment supplied at low voltage LVD 2014 30 EU Electromagnetic Compatibility EMC 2011 65 EU Restriction of the use of certain hazardous substances RoHS Other approvals The product meets...

Страница 7: ...ocket L 3m C6002 slim aluminium clamp 200 kg loading 48 51 mm tubes M10 bolt RSR0630A B steel security cable for hanging bodies inox steel shackle L 60 cm silver black STUDIOCOBPLUSL18 optics for STUD...

Страница 8: ...imary attachments by attaching a safety wire that is approved as a safety attachment for the weight of the fixture to an anchor point on the product main frame Do not use removable parts or weak ancho...

Страница 9: ...er from the product disconnect the Mains from the socket 4 CONNECTION TO THE MAINS SUPPLY WARNING For protection from electric shock the fixture must be earthed The product is equipped with auto switc...

Страница 10: ...t 4 DMX IN 5 p XLR 1 GND 2 sign 3 sign 4 N C 5 N C 5 POWER IN for connection to the Mains 100 240V 50 60Hz 6 USER INTERFACE with display and buttons for access to the control panel functions 7 DMX OUT...

Страница 11: ...e connection line Do not overload the link Up to 32 devices may be connected on a serial link CONNECTION DAISY CHAIN Connect the DMX data output from the DMX source to the product DMX input male conne...

Страница 12: ...be executing the same behaviour Selecting the same address to multiple fixtures can be useful for diagnostic purposes and symmetrical control DMX addressing is limited to make it impossible to set the...

Страница 13: ...r access to the control panel functions MENU used to access the menu tree or to return a previous menu window UP browse upwards through the menu list and increases the numeric value displayed DOWN bro...

Страница 14: ...0 255 4 Auto Show Auto 1 Auto 2 Auto 3 Auto 4 Auto 5 Speed 0 100 Speed 0 100 Speed 0 100 Speed 0 100 Speed 0 100 5 Master Slave Master Slave Allow you to link and operating in synk multiple units wit...

Страница 15: ...ctive 11 Key Lock On Of Allows you lock the buttons on the control panel by a password Press following com binations password in order to access to the user menu UP DOWN UP DOWN ENTER 12 Information F...

Страница 16: ...1 x x Power Lamp Settings DEVICE_HOURS 0x0400 x x LAMP_HOURS 0x0401 x x LAMP_STRIKES 0x0402 x x Display Settings DISPLAY_INVERT 0x0500 x x Control IDENTIFY_DEVICE 0x1000 x x 10 RDM FUNCTIONS The produ...

Страница 17: ...h 4 Ch 6 Ch 10 Ch 1 RED DIMMER DIMMER 2 GREEN RED RED 3 BLUE GREEN GREEN 4 WHITE BLUE BLUE 5 WHITE WHITE 6 STROBE STROBE 7 COLOR FUNCTION 8 COLOR PRESETS WHITE PRESETS COLOR MACRO 9 COLOR MACRO SPEED...

Страница 18: ...100 100 RGB 0 100 0 100 RGB 100 0 0 100 RGB 100 0 100 0 100 RGB 0 100 0 100 100 RGBW 100 100 100 100 WHITE PRESETS active when Color function is on White presets RGBW 2000K 3000K RGBW 3000K 4000K RGBW...

Страница 19: ...er using the four screws to the four holes on the front cover of the unit 2 C A B DETAIL Push the pin A and open upward the gel frame lock B Insert the filter frame C from above into the guides DETAIL...

Страница 20: ...ur holes on the front cover of the unit 2 C A B DETAIL Push the pin A and open upward the frame lock gel B Insert the barn doors C into from above by inserting the linking holders into the guides DETA...

Страница 21: ...A washer B front cover C glass lens D filter E Insert the optic by replacing the one already present and follow the reverse procedure to reassemble the parts NOTE To remove the accessory reverse the p...

Страница 22: ...other service operations on the product must be carried out by PROLIGHTS its approved service agents or trained and qualified personnel It is PROLIGHTS policy to apply the strictest possible calibrat...

Страница 23: ...ctors and connect them directly together to bypass one product at a time until normal operation is regained Once found the error have that fixture serviced by a qualified technician Timeout error afte...

Страница 24: ...Note...

Страница 25: ...Note...

Страница 26: ...Note...

Страница 27: ......

Страница 28: ...PROLIGHTS is a trademark of MUSIC LIGHTS S r l musiclights it prolights it support prolights it Via A Olivetti snc 04026 Minturno LT ITALY Tel 39 0771 72190...

Отзывы: