background image

11

ECLIPSEFS

3.4 STATIC

This mode is used to decide how the projector should operate.

•  Press the MODE button so many times until the display shows 

STATIC

, then press the button ENTER.

•  Press the UP/DOWN button to scroll through the menu, then select 

Play

 and press the ENTER button.

•  Press UP/DOWN to scroll through the menu, and then select one of the following settings:

 -

DMX Receive

 - The projector will need to operate based on the received DMX signal.

 -

Slave Receive

 - Means that the projector will act as a slave in a slave master chain, 

 -

Presets

 - The projector will be able to play the selected preset (

All, Red, Green, Blue, Lime, Cyan, Magenta, 

Yellow, Orange, Light Yellow, Light Blue, Light Pink, White 2700K, White 3200K, White 4200K, White 5000K, White 

5500K, White 6000K, White 7000K, White 8000K, White 9000K, White 10000K Tungsten (Red, Green Blue, Lime))

. This 

can be done as a 

Master

, that is the projector will act as a slave in a Master Slave chainas, as 

Alone 

or 

as

 DMX

, choosing the DMX chart at

 1CH.

 -

Color Mix 1-16

 - The projector will be able to play the selected preset (

All, Red, Green, Blue, Lime, Cyan, 

Magenta, Yellow, Orange, Light Yellow, Light Blue, Light Pink, White 2700K, White 3200K, White 4200K, White 5000K, 

White 5500K, White 6000K, White 7000K, White 8000K, White 9000K, White 10000K Tungsten (Red, Green Blue, Lime)

This can be done as a 

Master

, that is the projector will act as a slave in a Master Slave chainas, as 

Alone 

or as

 DMX

, choosing the DMX chart at

 1CH (

after activation thought 

Switch On 

option).

NOTE: if more mix colors have the ad 

on switch

, these will be played in sequence.

 -

Tungsten

 - Allow to choose the maximum value that each color must have when the 

1 ch Tungsten 

mode is used.

•  Press the ENTER button to confirm your choice.

•  Press the MODE button to go back or to meet the waiting time to exit the setup menu.  

3.5 LINKING

1.  Connect the DMX OUT of the master unit via 5-pole XLR cable to the DMX IN  of the first slave unit.

2.  Connect the DMX OUT of the first slave unit to the DMX IN of the second slave unit, etc. until all units 

are connected in a chain.

3.6 DMX CONFIGURATION

ECLIPSEFS  is equipped with different DMX configuration. 

•  Press the button MODE so many times until shows 

CONNECT

, and press the button ENTER to confirm.

•  Select 

Mode 

through the buttons UP/DOWN, then press the button ENTER.

•  Select the desired DMX configuration (

1CH - - 2CH - 3CH - 3CHRGB - 4CH RGBL- 5CH - 5CHRGBL - 8CH - 13CH - 1CH 3200K 

- 1CH 5400K - 1CH 6500K

) through the buttons UP/DOWN.

The tables on page 13 indicate the operating mode and DMX value. The ECLIPSEFS is equipped with 

5-pole XLR connections.

3.7 DMX MODE

•  Press the button MENU so many times until the display shows 

CONNECT

, and press the button ENTER to 

confirm.

•  Select 

DMX Address 

through the buttons UP/DOWN, then press the button ENTER.

•  Press UP/DOWN button to select the desired value (

001-512

). Press and hold to scroll quickly.

•  Press ENTER button to store.

•  Press the MODE button to go back or to meet the waiting time to exit the setup menu.

To able to operate the ECLIPSE with a light controller, adjust the DMX start address for the first a DMX 

channel. If e. g. address 33 on the controller is provided for controlling the function of the first DMX 

channel, adjust the start address 33 on the ECLIPSE. The other functions of the light effect panel are then 

Содержание ECLIPSEFS

Страница 1: ...ECLIPSEFS OPTIC 14 19 26 36 50 USER MANUAL ECLIPSEFS EN LED PROFILER ...

Страница 2: ...y any means for any commercial use In order to improve the quality of products PROLIGHTS reserves the right to modify the characteristics stated in this instruction manual at any time and without prior notice All revisions and updates are available in the manuals section on site www prolightsamerica com ...

Страница 3: ...ture 3 4 Static mode 3 4 Static mode 3 5 Linking 3 5 Linking 3 6 DMX configuration 3 6 DMX configuration 3 7 DMX mode 3 7 DMX mode 3 8 Fixture ID and RDM 3 8 Fixture ID and RDM 3 9 Connection of the DMX line 3 9 Connection of the DMX line 3 10 Construction of the DMX termination 3 10 Construction of the DMX termination 3 11 DMX control 3 11 DMX control 3 12 Setup 3 12 Setup 3 13 Avanced 3 13 Avanc...

Страница 4: ...al which is not harmful to the environment Warnings and installation precautions If this device will be operated in any way different to the one described in this manual it may suffer damage and the guarantee becomes void Furthermore any other operation may lead to dangers like short circuit burns electric shock etc Before starting any maintenance work or cleaning the projector cut off power from ...

Страница 5: ...3 ECLIPSEFS 1 INTRODUCTION 1 1 TECHNICAL DRAWING Technical drawing Fig 1 259 4mm 10 21mm 268 8mm 10 58in 663 3mm 26 11in ECLIPSEFS OPTIC ...

Страница 6: ...or Housing Middle part compatible with 14 19 26 36 50 optics 2 Optics for ECLIPSE profiler 14 beam Optics for ECLIPSE profiler 19 beam Optics for ECLIPSE profiler 26 beam Optics for ECLIPSE profiler 36 beam Optics for ECLIPSE profiler 50 beam ECLIPSEFS OR ...

Страница 7: ...t of breakage always replace the fuse with the same type and rating 11 CONTROL PANEL with display and 4 button used to access the control panel functions and manage them 12 POWER OUT PowerCON OUT connect to supply power to the next unit 13 POWER IN PowerCON IN for connection to a socket 100 240V 50 60Hz via the supplied mains cable 14 DMX OUT 5 pole XLR 1 ground 2 DMX 3 DMX 4 N C 5 N C 15 DMX IN 5...

Страница 8: ...stallation always comply scrupulously with all the regulations particularly re garding safety currently in force in the country in which the fixture s being used Install the projector at a suitable location by means of the mounting bracket 1 Always additionally secure the projector with the safety rope from falling down For this purpose fas ten the safety rope at a suitable position so that the ma...

Страница 9: ...o a socket which can be switched on and off via a light switch 3 2 BASIC Access control panel functions using the four panel buttons located directly underneath the LCD Display fig 4 MODE ESC UP DOWN ENTER Used to access the menu or to return a previous menu option Navigates downwards through the menu list and increases the numeric value when in a function Navigates upwards through the menu list a...

Страница 10: ...rature C F Fahrenheit Celsius Default Celsius MaxTemp 60 90 C 140 194 C Default 90 C Screen ð Backlight ð Off 99m Default 02m Flip Display ð Yes No Default No Fixture ð Fan mode ð Auto Speed High Speed Default Auto Speed Hibernation Disable Min 1 99 Default Disable Theatre Yes No Default No LED frequency ð 600Hz 1200Hz Default 1200Hz Adjust ð Dimmer 3 ADVANCED ð Dimmer ð OFF Dimmer 1 Default Dimme...

Страница 11: ...eive Slave Receive Presets ð Master Alone DMX Color MIX ð Master Alone DMX Presets ð All Red Green Blue Lime Cyan Magenta Yellow Orange LightY Light B Light P 2700K 3200K 4200K 5000K 5500K 6000K 7000K 8000K 9000K 10000K Tungsten ð Red Green Blue Lime Color Mix 1 ð Switch HoldTime FadeTime Dimmer ð On Off Default On Color Mix 16 ð Switch HoldTime FadeTime Dimmer ð On Off Default On ...

Страница 12: ...ECLIPSEFS 10 6 DEFAULT ð Basic Reload ð On Off Program Reload ð On Off Password Private Reload Recover calibration and RDM PID code ð On Off All Reload Recover calibration and RDM PID code ð On Off ...

Страница 13: ...ese will be played in sequence Tungsten Allow to choose the maximum value that each color must have when the 1 ch Tungsten mode is used Press the ENTER button to confirm your choice Press the MODE button to go back or to meet the waiting time to exit the setup menu 3 5 LINKING 1 Connect the DMX OUT of the master unit via 5 pole XLR cable to the DMX IN of the first slave unit 2 Connect the DMX OUT ...

Страница 14: ...the connections The RDM data is transmitted via the standard XLR poles 1and 2 new DMX cables are not necessary RDM ready and conventional DMX devices can be operated in one DMX line The RDM protocol sends own packages in the DMX512 data feed and does not influence conventional devices If DMX splitters are used and RDM control is to be used these splitters must sup port RDM The number and type of R...

Страница 15: ...f the first unit Connect the DMX output to the DMX input of the following unit Connect again the output to the input of the following unit until all the units are connected in chain When the signal cable has to run longer distance is recommended to insert a DMX termination on the last unit 3 10 CONSTRUCTION OF THE DMX TERMINATION The termination avoids the risk of DMX 512 signals being reflected b...

Страница 16: ...ne CTC Fine 000 255 2 1 1 2 2 3 Red Red 0 100 000 255 4 Red fine Red fine 0 100 000 255 3 2 2 3 3 5 Green Green 0 100 000 255 6 Green fine Green Fine 0 100 000 255 4 3 3 4 4 7 Blue Blue 0 100 000 255 8 Blue fine Blue Fine 0 100 000 255 5 4 5 5 9 Lime Lime 0 100 000 255 10 Lime fine Lime Fine 0 100 000 255 6 11 CTC Preset No function 2000K 2700K 2700K 3200K 3200K 4200K 4200K 5600K 5600K 8000K 8000K...

Страница 17: ...u can set using the arrow buttons To have the display or set a value of Off 99 min to turn off the display after the amount of time you choose Flip Display Orientation of the display This function allows you to rotate the display 180 to get a better view of the display when the unit is hanging upside down Select Yes to activate or No to dis able this function Press the ENTER button to confirm your...

Страница 18: ...roposed Code CHxx and press the ENTER button to confirm the setting Press the MODE button to go back and save changes 3 14 FIXTURE INFORMATION To view all the information on the device proceed as follows Press the button MODE so many times until the display shows INFORMATION then press the button EN TER Press the UP DOWN button to scroll through the menu then select one of the following informatio...

Страница 19: ...netrate the unit and cause damage to it 4 2 FUSE REPLACEMENT 1 Remove the safety cap by a screwdriver 2 Replace the blown fuse with a fuse of the exact same type and rating 3 Install the safety cap and reconnect power 4 3 TROUBLESHOOTING Fig 8 Problems Possible causes Checks and remedies Fixture does not light up No mains supply Dimmer fader set to 0 All color faders set to 0 Faulty LED Faulty LED...

Страница 20: ......

Отзывы: