3
4
5
9
8
12 13 14
10
15
11
2
1
6
7
Fig.2
5
ECLFR2KTU-DY
1.3 OPERATING ELEMENTS AND CONNECTIONS
1. VENTILATION GRID for air flow outlet not to
be obstructed.
2. Knob for inclination adjustment.
3. HANDLE
4. MOUNTING BRACKET
5. SPIGOT
6. CONTROL PANEL with display and 1 button
used to access the control panel functions
and manage them.
7. ZOOM ADJUSTMENT Knob AND FOCUS to
zoom the projected image clearly.
8. GEL FILTER FRAME
9. BARN DOOR with directional flaps to adjust
the light beam.
10. GUIDE for locking and releasing accessories
11. MAIN FUSE HOLDER: replace a burnt-out fuse by
one of the same type only
12. POWER IN (PowerCON TRUE IN): for connection
to a socket (100-240V~/50-60Hz) via the supplied
mains cable.
13. DMX IN (5-pole XLR): 1 = ground, 2 = DMX-, 3 =
DMX+, 4 N/C, 5 N/C.
14. DMX OUT (5-pole XLR): 1 = ground, 2 = DMX-, 3 =
DMX+, 4 N/C, 5 N/C.
15. POWER OUT (PowerCON TRUE OUT): power
output for connection of multiple units in series.
Содержание ECLFR2KTU-DY