ProLights Astra Hybrid420IP Скачать руководство пользователя страница 6

PROLIGHTS - Astra 

Hybrid420IP

04

Do not stare at the operating light source

•  Do not look directly at the LED source during operation. It can be harmful to the eyes 

and skin.

• 

During Installation, operation and maintenance, be prepared for the fixture to light 

and move suddenly when connected to power.

•  The device should be positioned so that prolonged staring into the luminaire at a 

distance closer than 4.439 m (14.563 ft) is not expected.

 

Minimun

distance

Risk

Group 2

Risk

Group 1

 

0.2 m

0.7 ft

4.439 m

14.563 ft

Disposal

• 

This product is supplied in compliance with European Directive 2012/19/EU – Waste 

Electrical and Electronic Equipment. (WEEE). To preserve the environment please 

dispose/ recycle this product at the end of its life according to the local regulation.

The product contains a lithium ion battery

•  Don't throw the unit into the garbage at the end of its lifetime.
• 

Make sure to dispose according to your local ordinances and/or regulations, to avoid 

polluting the environment!

•  The packaging is recyclable and can be disposed.

The products to which this manual refers comply with:

• 

2014/35/EU - Safety of electrical equipment supplied at low voltage (LVD);

• 

2014/30/EU - Electromagnetic Compatibility (EMC);

• 

2011/65/EU - Restriction of the use of certain hazardous substances (RoHS);

• 

2014/53/EU - Radio Equipment Directive (RED).

The products to which this manual refers comply with:

• 

UL 1573 + CSA C22.2 No. 166 - Stage and Studio Luminaires and Connector Strips.

• 

UL 1012 + CSA C22.2 No. 107.1 - Standard for power units other than class 2.

FCC Compliance:

•  This device complies with Part 15 of the FCC Rules. Operation is subject to the fol

-

lowing two conditions:

3.  This device may not cause harmful interference, and

4.  This device must accept any interference received, including interference that may 

cause undesired operation.

Other approvals

•  The product meets the safety requirements of the certification procedures of the 

market in which it is placed and sold.

Содержание Astra Hybrid420IP

Страница 1: ...USER MANUAL REV 01 09 22 English version Astra Hybrid420IP IP65 Hybrid moving beam spot with a 420W USHIO NSL421 lamp...

Страница 2: ...onomic loss or any other loss occasioned by the use of inability to use or reliance on the information contained in this document Product user manual can be downloaded from the website www prolights i...

Страница 3: ...HE DMX TERMINATION 11 DMX ADDRESSING 11 ETHERNET CONNECTION 11 ETHERNET OPERATION 11 ETHERNET TO DMX OPERATIONS 12 OPERATION AS A WIRELESS TRANSMITTER 12 IN TO WDMX 12 OPERATION AS A WIRELESS RECEIVER...

Страница 4: ...t requirements of all connected devices Isolate the fixture from power immediately if the power plug or any seal cover cable or other components are damaged defective deformed or showing signs of over...

Страница 5: ...system Avoid to expose the optical system to any intense source of light including sunlight from any angle T 69 C c Temperature of the external surface The surface of the fixture can reach up to 85 C...

Страница 6: ...time Make sure to dispose according to your local ordinances and or regulations to avoid polluting the environment The packaging is recyclable and can be disposed The products to which this manual ref...

Страница 7: ...G5 transmitter 2 45GHz 5 2 5 8 GHz DMX RDM 512Ch 958225L03 3x2 5mm TH07 Cable 16A 3p PwCon MXW 16A 3p PwCon FXW L 3m 9513FXWL03 ass 3x2 5mm TH07 cable 16A 3p 230V CEE plug MENAC3FXW socket L 3 m 9533...

Страница 8: ...PROLIGHTS Astra Hybrid420IP 06 3 PAN AND TILT LOCK PAN Mechanism lock and release 9 0 9 0 9 0 9 0 TILT Mechanism lock and release 45 4 5 45 4 5 4 5 4 5 Fig 02...

Страница 9: ...of primary attachments by attaching a safety wire that is approved as a safety attachment for the weight of the fixture to an anchor point on the product main frame Do not use removable parts or weak...

Страница 10: ...ower from the product disconnect the Mains from the socket 5 CONNECTION TO THE MAINS SUPPLY WARNING For protection from electric shock the fixture must be earthed The product is equipped with auto swi...

Страница 11: ...GND 2 sign 3 sign 4 N C 5 N C 4 DMX IN 5 p XLR 1 GND 2 sign 3 sign 4 N C 5 N C 5 MAIN FUSE HOLDER replace a burnt out fuse by one of the same type only 250VAC T8A 6 GORE VALVE 7 POWER IN for connecti...

Страница 12: ...he connection line Do not overload the link Up to 32 devices may be connected on a serial link CONNECTION DAISY CHAIN Connect the DMX data output from the DMX source to the product DMX input male conn...

Страница 13: ...en the main menu 2 Reach the addressing menu then select the DMX ADDRESS settings 3 Select the address from 1 to 512 using the navigation arrows buttons and confirm by pressing ENTER 4 Press Menu to e...

Страница 14: ...for select WIRELESS then press ENTER to confirm 3 Push ENTER button on WDMX ON OFF function and enable it to ON 4 Select WDMX mode and set it on Transmitter please note that WDMX mode will be availabl...

Страница 15: ...er enable TX LINK to ON to link transmitter to the receivers 7 If the connection is successful and DMX input is available the display the display on the receiver unit will shows the DMX address If DMX...

Страница 16: ...1 Browse upwards through the menu list and increases the numeric value displayed 2 Return to the top level 3 Browse downwards through the menu list and de creases the numeric value displayed 4 Commut...

Страница 17: ...otal reset of the receiver RX reset unlocks only if WDMX mode is receiver IN TO WDMX TX ON OFF Enable Disable the transmission of the DMX values via wdmx WDMX TO DMX RX ON OFF Enable Disable the retra...

Страница 18: ...se the home position CUSTOM CUSTOM P DEGREE 0 To choose pan values in case of Custom position 315 CUSTOM T DEGREE 0 To choose tilt values in case of Custom position 100 FIXTURE SETTINGS LAMP TURN ON O...

Страница 19: ...cycles of the machine PARTIAL READ AND RESET LAMP HOURS TOTAL READ AND RESET To see the total operating hours of the LAMP PARTIAL READ AND RESET LAMP STRIKE TOTAL READ AND RESET To see the total amou...

Страница 20: ...ip display without enter inside menu DOWN then power on Reset without pan tilt movements Fixture will be powered on without reset on pan tilt movements ENTER UP then power on Bootloader Force firmware...

Страница 21: ...col over a DMX512 Networks RDM is a bi directional communications protocol for use in DMX512 control systems it is the open standard for DMX512 device configuration and status monitoring The RDM proto...

Страница 22: ...ME_CLOCK 0x0603 x x LOCK_PIN 0x0640 x x LOCK_STATE 0x0641 x x LOCK_STATE_DESCRIPTION 0x0642 x Control IDENTIFY_DEVICE 0x1000 x x RESET_DEVICE 0x1001 x POWER_STATE 0x1010 x x PERFORM_SELFTEST 0x1020 x...

Страница 23: ...id420 21 13 DMX CHARTS DMX Chart Summary Channel Standard 1 Pan 2 Pan Fine 3 Tilt 4 Tilt Fine 5 Dimmer 6 Dimmer Fine 7 Shutter 8 Cyan 9 Magenta 10 Yellow 11 Color Wheel 1 12 Color Wheel 2 13 Color Whe...

Страница 24: ...255 10 YELLOW Linear insertion from 0 to 100 Color Wheel 3 must be 0 000 255 255 11 COLOR WHEEL 1 Indexed Open Open UV UV UV Lavander Lavander Lavander CTO 3200K CTO 3200K CTO 3200K CTO 2500K CTO 250...

Страница 25: ...9 Forward Spin From fast to slow Stop Stop Reverse Spin From slow to fast Shake Gobo 1 from slow to fast Gobo 2 from slow to fast Gobo 3 from slow to fast Gobo 4 from slow to fast Gobo 5 from slow to...

Страница 26: ...om slow to fast Gobo 17 from slow to fast Gobo 18 from slow to fast 0 3 4 7 8 11 12 15 16 19 20 23 24 27 28 31 32 35 36 39 40 43 44 47 48 51 52 55 56 59 60 63 64 67 68 71 72 75 76 127 128 129 130 181...

Страница 27: ...ESET FOCUS RESET ANIMATION RESET 4F PRISM RESET 8F PRISM RESET FROST RESET SHUTTER RESET OTHER LAMP OFF LAMP ON Reserved FACTORY DEFAULT OF CONTROL FUNCTIONS 096 097 098 099 100 101 102 103 104 105 10...

Страница 28: ...ESET FOCUS RESET ANIMATION RESET 4F PRISM RESET 8F PRISM RESET FROST RESET SHUTTER RESET OTHER LAMP OFF LAMP ON Reserved FACTORY DEFAULT OF CONTROL FUNCTIONS 096 097 098 099 100 101 102 103 104 105 10...

Страница 29: ...1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 Open 14 FIXED GOBOS WHEEL Fig 09 PROLIGHTS Astra Hybrid420IP 27...

Страница 30: ...s Type B external OD 15 9 mm of image ID 12 mm Thinckness 1 1 mm Slot 01 Slot 02 Slot 03 Slot 04 Slot 05 Slot 06 Slot 07 Slot 08 Slot 09 Open ATTENTION Load with mirror surface toward the light source...

Страница 31: ...YAN COLOR WHEEL 1 3200K 2500K BLUE WOOD LAVANDER UV MAGENTA COLOR WHEEL 2 DARK BLUE DARK RED DARK GREEN H M GREEN CTB YELLOW COLOR WHEEL 3 DARK ORANGE LIGHT ORANGE PINK AQUAMARINE LIGHT GREEN PROLIGHT...

Страница 32: ...ixture to cool down 1 2 Before removing rear cover place the head in a right angle horizontal position and engage both the PAN and TILT locks for added stability while replacing the lamp 1 See the PAN...

Страница 33: ...PROLIGHTS Astra Hybrid420IP 31 4 5 Loosen the two marked screws 5 and open the module with the two fan 6...

Страница 34: ...metal locking plate above and remove the lamp Carefully remove any debris found on gasket and screw holes of the heatsink module using a nonabra sive brush before installing Carefully inspect gaskets...

Страница 35: ...ated via Cali bration Menu Once calibration mode is on you can start calibration process As soon as you finished calibration please hold for 5s DOWN button again to leave calibration mode LAMP FAN ERR...

Страница 36: ...not located in the default position after the reset of the fixture Blue 2U PAN SENSOR ERROR Pan sensor not detected Blue 2U TILT SENSOR ERROR Tilt sensor not detected Blue 2U PAN ENCODER ERROR Pan enc...

Страница 37: ...IDENTIFICATION OF ELECTRONIC BOARDS 1U PCB 2U PCB 3U PCB 4U PCB 5U PCB Fig 14 PROLIGHTS Astra Hybrid420IP 35...

Страница 38: ...rear cover place the head in a horizontal position and engage both the PAN and TILT locks for added stability See the PAN AND TILT LOCK paragraph Loosen the marked screws and opening the head covers...

Страница 39: ...EPLACEMENT 1 Loosen the marked screws and opening the head cover see the PERIODICAL CLEANING paragraph point 2 2 3 Detach the gobo holder flap from the gobo wheel 2 Then remove the gobo holder 3 4 5 R...

Страница 40: ...P 38 1 Remove the gore valve from the connections panel 2 Connect the air hose to the IPTESTBOX by inserting the quick connect fitting into the coupler 21 TEST OF IP65 RATING To check sealing after se...

Страница 41: ...to the threaded valve hole socket 4 5 Remove the gore valve on the rear connection heatsilk module 4 and insert the hex socket cap head included in the IPTESTBOX box 5 For the operating procedure usin...

Страница 42: ...ied personnel It is PROLIGHTS policy to apply the strictest possible calibration procedures and use the best quality materials available to ensure optimum performance and the longest possible componen...

Страница 43: ...ectors and connect them directly together to bypass one product at a time until normal operation is regained Once found the error have that fixture serviced by a qualified technician Timeout error aft...

Страница 44: ...Note...

Страница 45: ...Note...

Страница 46: ...Note...

Страница 47: ......

Страница 48: ...PROLIGHTS is a trademark of MUSIC LIGHTS S r l musiclights it prolights it support prolights it Via A Olivetti snc 04026 Minturno LT ITALY Tel 39 0771 72190...

Отзывы: