15
9 - MENU STRUCTURE
The following chart describes the MENU tree of the product, the terms shown in
BOLD
indicates the
default settings.
MENU*
1 DMX_START_ADDRESS
001
- 512
2 DMX_PERSONALITY
FC Variant Mode
VW Variant Mode
1CH
1CH
2CH
2CH
5CH
3CH
9CH
4CH
12CH
9CH
available only on M18 variant
14CH
9CH2
3 CURVE
0:LINEAR
To choose the dimmer curve.
1:S-CURVE
2:SQUARE LAW
3:INVERSE SQUARE LAW
4 OUTPUT_RESPONSE_TIME
0:AUTO
To choose the dimmer speed.
1:FAST
2:MEDUIM
3:SLOW
5 MODULATION_FREQUENCY
0:600Hz
Select PWM frequency.
1:1200Hz
2:2000Hz
3:4000Hz
4:6000Hz
5:25kHZ
SPECIAL PIDs**
1 DMX FAULT
0:BLACKOUT
To choose the behaviour of fixture in case of
dmx signal lost.
1:HOLD
2:STAND ALONE
2 MASTER/SLAVE
0:MST DMX
Outputs dmx signal.
1:MST NO DMX
Doesn't output dmx signal.
2:SLAVE
Receive dmx signal.
3 STAND ALONE MODE
0:EFFECTS
To use onboard effects
1:STATIC
To use static color presets.