5.3. DMX-512 Connections
To avoid signal errors, the end of the serial DMX-512
link must be terminated. Insert a terminator plug (XLR
connector with a 120
/ ¼ W resistor between pin 2
and 3) in the DMX output socket of the last unit in the
link.