19
6.1.2 Select Battery Switch Local/Remote
This function offers a possibility for user to use a remote battery switch to power on/off the service battery output
DIP SWITCH
DESCRIPTION
Local
The switch on PM335 unit works
Remote
The remote switch works and local one
is disabled
Figure 27 Local/Remote Select Switch Table 15 Local/Remote Setting
Local
Remote
6.2 Configuration on Monitor
Access to the configuration menu is safeguarded with a passcode. The default is 0000 and may be set by a user.
Passcode Descriptions
0000
Factory Default, no passcode
1999
Factory access passcode
XXXX
User define
Press the ‘Light’ button until the setting code is showing on the date time area which means the monitor is ready for configuration.
The ‘PUMP’ button and ‘LOAD’ button can be used to scroll through the configuration menu.
CODE
FUNCTION
DESCRIPTION
Time Setting
Set date system 12H/24H and date.
Battery Setting
Battery Type
AGM / GEL / LFP (LiFePO
4
)/WET
Battery Capacity
Battery Low Voltage Protection
To shutdown the output of loads
Pump
Pumps enable or disable
Pump 1
Select Pump 1
Pump 1 ON
Pumps 1enable
Pump 1 OFF
Pump 1 disable
Restore factory defaults
Cancel
Cancel to restore factory defaults
Accept
Confirm to restore factory defaults
Version
Software version of devices. read only
CMP
Software Version of PM335
LCD
Software Version of LCD
Cut off Bluetooth
Shut down connection of Crystal to APP
Update enable
Enable to update firmware
Table 16 Setting code of the Monitor