Projecta INTELLI-RV PM300-BT Скачать руководство пользователя страница 1

INTELLI-RV

12V POWER MANAGEMENT SYSTEM

P/No. PM300-BT

Содержание INTELLI-RV PM300-BT

Страница 1: ...INTELLI RV 12V POWER MANAGEMENT SYSTEM P No PM300 BT...

Страница 2: ...l wiring rules Do not attempt to charge non rechargeable batteries Never charge a frozen battery If theAC cord is damaged do not attempt to use It must be replaced or repaired by a qualified technicia...

Страница 3: ...10 3 3 Water tank probe 11 3 3 1 PMWS400 water tank probe 11 3 3 2 PMWS200 water tank probe 11 4 WIRING 12 4 1 Material 12 4 2 System schematic 13 4 3 Preparation 14 4 4 Connection 14 5 DISPLAY 15 5 1...

Страница 4: ...ser friendly interface SYSTEM COMPONENTS 1 Master Power Unit 2 Monitor 3 4Water tank sensors Not supplied 4 Cables Refer to Chapter 4 1 for the cable list Figure1SystemComponentsforPM300 BT P No PMLCD...

Страница 5: ...arter battery Solar charge controller MPPT 30A 14 built in fused outputs Charging fromAlternator at 12V 60A 60A continuously 100A 30mins Low battery voltage protection Built in battery switch to isola...

Страница 6: ...e optimal charging for batteries of different states the PM300 BT features Microprocessor controlled charging algorithm The Float and Recycle charging programs guarantees that the battery condition do...

Страница 7: ...er for the service battery with Max input voltage 50VDC Max charging current 20A Max supply current 30A 2 6Voltage Charging Relay VCR or commonly known as aVSR PM300 BT master power unit has a built i...

Страница 8: ...ategorisedoutputs TYPE QTY DESCRIPTION POSSIBLE LOAD SUITABLE Class A1 1 Relay controlled output with fuse protected by main master switch relay Water pump Class B 10 Fused outputs protected by master...

Страница 9: ...12 Starter Bat Starter battery Connect to starter battery 20Vdc 13 Service Bat Service battery Connect to service battery 20Vdc 14 Starter Bat Starter battery Connect to starter battery 15 Service Ba...

Страница 10: ...5 can be installed on a horizontal surface or vertically on a wall Please see following instructions Figure10InstallationofPM335 Unit mm Ensure clearance on both sides of PM335 unit upon installation...

Страница 11: ...Unit mm 3 3WaterTank Probe 3 3 1 PMWS400WaterTank Probe Figure13DimensionofPMWS400 Unit mm Figure14InstallationofPMWS400 3 3 2 PMWS200WaterTank Probe Installation Figure15DimensionofPMWS200 Unit mm Fi...

Страница 12: ...l sensor 0 7 7 Solar 0 9 10 Communication line RS485 5m 1 PMLCDC 11 Temperature line 5m 1 PMTS 12 Battery sensor line 3m 1 PMBS 13 Water tank probe line Not included 0 PMWS200 PMWS400 14 Water tank pr...

Страница 13: ...Water Tank Level Sensor N L AC IN Monitor Switch Panel Battery Sensor Waste Water Tank Tap Water Tank Fresh Water Tank 2 Fresh Water Tank 1 L12 L13 L14 L14 L13 L12 L11 L10 L9 L8 L7 L6 L5 L4 L3 L2 L1 P...

Страница 14: ...MINIMUM CABLE SIZE 0 5A 1 0mm2 or 18AWG 5 10A 2 0mm2 or 14AWG 10 15A 3 0mm2 or 13AWG 15 20A 4 0mm2 or 11AWG 20 25A 5 0mm2 or 10AWG 25 30A 6 0mm2 or 9AWG Table5Minimumcablesize Table6Recommendedtermin...

Страница 15: ...mal but it is charged by theAC or Starter battery Quick flashing flash twice every second Solar input voltage error Solar voltage 50Vdc OFF Solar disconnected 4 CHG GREEN ON Battery charged Slow flash...

Страница 16: ...charging relay VCR is connected Voltage charging relay VCR is disconnected 7 Output power Voltage of system output Current of system output Table8SymbolExplanation Chargingstate Pump Upswitch Silent E...

Страница 17: ...tailed steps are shown as below Figure 23 LOAD To switch off all the loads connected on DC charger The function is the same as load switch in PM4SW10 The detailed steps are shown as below Figure 24 LI...

Страница 18: ...LFP LiFePO4 14 4V 13 5V ON ON WET 14 7V 13 7V Figure26ReminderwhenconflictsettingbetweenPM335andmonitor Whenthebatterytypeandcapacitysettingonhemonitorisnot thesameasPM335dipswitch theiconswillbeflash...

Страница 19: ...etting code is showing on the date time area which means the monitor is ready for configuration The PUMP button and LOAD button can be used to scroll through the configuration menu CODE FUNCTION DESCR...

Страница 20: ...eBluetoothconnection Setyear Setmonth Setdate Set12 houror24 hour Sethour Setminute SelectAGMbattery SelectGELbattery SelectLFPbattery SelectWETbattery Enabletocontrol pump1 Disabletocontrol pump1 Dis...

Страница 21: ...new one please have the new battery fully charged by Grid for the first time to calibrate a precise battery SOC Every 3 months the monitor will display a code 8018 suggesting maintenance If you have...

Страница 22: ...13 4V or 16 0V while AC power is connected 3 PV Green Quick flashing flash twice every second Solar input voltage error Solar Input 50Vdc 4 Fuse LED Red Solid Fuse blown need to check load and replace...

Страница 23: ...t current 35A Continuous Efficiency 88 Working temperature 40 C 65 C 50 C full load 60 C 20A 65 C shutdown the output MODEL PM335 ELECTRICAL SPECIFICATIONS Battery Disconnect LVD Disconnect voltage AG...

Страница 24: ...f purchase together with an explanation in writing as to the nature of the claim In the event that the claim is determined to be for a minor failure of the product then BWI reserves the right to repai...