3. Operation
3.1 Configuration
SIDE PANEL
3.2 Wiring
WIRING SIZE:
DC cables must be sized to carry the maximum full load current and not to exceed the
system volt drop requirements. The following cable sizes are recommended. When running
wires, if they pass through panels or wall, ensure the wires are protected from damage by
sharp edges. The use of additional cable insulation or tubing is recommended.
No.
LABEL
DEFINITION
DESCRIPTION
1
Power
AC cable
Kettle /computer/IEC type plug
2
RS485
Communication
Connect to PMBTJ-02
3
Load Switch
Low power consumption
Connect external switch
4
Vehicle Bat+
Vehicle battery terminal
Connect to vehicle
5
Vehicle Bat-
Connect to vehicle battery-
6
House Bat+
House battery terminal
Connect to house
7
House Bat+
Connect to house battery-
8
Load+
Centralised output connect
Connect to high output load+
9
Load-
Connect to high output load-
10
L1+
L8+
Separated DC outputs connector
Connect to DC load+
11
L9+
Connect to DC load+
12
L10+
Connect to DC load+
13
L10-
Connect to DC load-
14
L9-
Connect to DC load-
15
L8-
L1-
Connect to DC load-
CURRENT
MINIMUM CABLE SIZE
0-5A
1.0mm or 18 AWG
5-10A
2.0mm or 14AWG
10-15A
3.0mm or 13AWG
15-20A
4.0mm or 11AWG
20-25A
5.0mm or 10AWG
25-35A
6.0mm or 9 AWG
1
2
3 4 5 6 7 8 9
10
11121314
15