IMPORTANT SAFETY INFORMATION

Please read this manual thoroughly before use and store in a safe place for future 
reference.

WARNING

• Explosive gases may escape from the battery during charging. Prevent flames and 

sparks. Provide adequate ventilation.

• Before charging, read the instructions.
• For indoor use. Do not expose to rain.
• For charging 12 Volt lead acid and lithium batteries ONLY.
• Disconnect the 240V mains supply before making or breaking the connections  

to the battery.

• The battery charger must be plugged into an earthed socket-outlet.
• Connection to supply mains is to be in accordance with National wiring rules.
• Do not attempt to charge non-rechargeable batteries.
• Never charge a frozen battery.
• If the AC cord is damaged do not attempt to use. It must be replaced or repaired by  

a qualified person.

• Corrosive substances may escape from the battery during charging and damage delicate 

surfaces. Store and charge in a suitable area.

• Ensure all vehicle accessories including lights, heaters, appliances etc are turned off 

prior to charging.

• This charger is not intended for use by persons (including children) with reduced 

physical, sensory or mental capabilities, or lack of experience and knowledge, unless 
they have been given supervision or instruction concerning use of the appliance by a 
person responsible for their safety.

• Young children should be supervised to ensure that they do not play with the appliance.

Содержание INTELLI-CHARGE IC10

Страница 1: ...INTELLI CHARGE 12 VOLT 7 STAGE SWITCHMODE BATTERY CHARGER P No s IC7 IC7W IC10 IC15...

Страница 2: ...iring rules Do not attempt to charge non rechargeable batteries Never charge a frozen battery If the AC cord is damaged do not attempt to use It must be replaced or repaired by a qualified person Corr...

Страница 3: ...Soft Start Bulk Absorption Analysis Recondition and Float Desulphation The Desulphation stage is designed to break down sulphation occurring in batteries that have been left flat for extended periods...

Страница 4: ...smallest 1 Amp unit up to the largest 50 Amp offering world class electronics guarantee the battery receives the ultimate charge to ensure maximum life and performance over the life of the battery Th...

Страница 5: ...cting the battery from the vehicle WIRING HARNESS IC7 ONLY The wiring harness allows for easy connection to vehicles that have hard to reach batteries Includes an inline fuse to protect the harness fr...

Страница 6: ...nce COOLING FAN The charger is fitted with a thermostatically controlled fan to cool onboard electronics and maintain charging performance The cooling fan will engage automatically when there is a hig...

Страница 7: ...ut Analysis Monitors battery for 90 sec Recondition Constant current Constant current Constant current 0 15A 1 05A for 0 3A 1 5A for 0 3A 2 25A for 4 hours limited to 4 hours limited to 4 hours limite...

Страница 8: ...es Power Charging and Fully Charged Mounting Flange Adjustable Charge Rate Battery Chemistry Selection Mode Button LED Battery Chemistry Display Indicates selected battery chemistry type Power Cord DC...

Страница 9: ...distilled water to the correct level and refit the vent caps STEP 2A CONNECTION OUT OF THE VEHICLE Connect the RED lead battery clip from the charger to the Positive battery post Connect the BLACK le...

Страница 10: ...EL AGM WET CALCIUM PWRSUPPLY 1A 2A 4A 7A IC7 12V7A7 STAGE CHARGE RATE MODE POWER ON CHARGING FULLY CHARGED I N T E L L I C H A R G E 1 2 V 7 A B A T T E R Y C H A R G E R Connection in vehicle negativ...

Страница 11: ...4h Time 2 10 4 20 8 40 12 60 2 10h 2 10h 2 10h 2 10h 14 70 2 10h 16 80 2 10h 20 100 2 10h 30 150 2 10h LITHIUM GEL AGM WET CALCIUM PWRSUPPLY 1A 2A 4A 7A IC7 12V7A7 STAGE CHARGE RATE MODE POWER ON CHAR...

Страница 12: ...tell what stage the battery charger is in in the FAQ section page 17 When the FULLY CHARGED LED remains on this is known as the float stage and the charger can be left connected to the battery withou...

Страница 13: ...arance from the end plates to provide adequate ventilation for the cooling fan LITHIUM GEL AGM WET CALCIUM PWRSUPPLY 1A 2A 4A 7A IC7 12V7A7 STAGE CHARGE RATE MODE POWER ON CHARGING FULLY CHARGED 3 5mm...

Страница 14: ...ng terminal FOR LEAD ACID CELL BATTERIES Connection 1 Cut off the supplied battery clips ensure you leave sufficient cable to reach the battery terminals DO NOT extend the battery charger DC cables as...

Страница 15: ...4 2 VOLTS Charger will use a lithium specific 5 stage charging algorithm GEL MAX VOLTAGE OF 14 1 VOLTS This charge mode is designed for GEL batteries and has a maximum charge voltage of 14 1V Note tha...

Страница 16: ...isable the CHARGE RATE MODE keys from use This function is ideal for hire vehicles etc as it prevents the chargers settings from being altered if the keys are touched To lock press and hold the CHARGE...

Страница 17: ...moved Q Can I use the charger as a power supply A Yes by selecting Power Supply mode you are able to use the charger as a power supply to run an appliance Ensure the appliance being run is not greater...

Страница 18: ...ent battery chemistry for charging my battery A Yes the battery chemistry selection can be different to your battery type if the charge voltages match the battery manufacture s recommendations Q Why d...

Страница 19: ...19 NOTES...

Страница 20: ...of purchase together with an explanation in writing as to the nature of the claim In the event that the claim is determined to be for a minor failure of the product then BWI reserves the right to rep...