SELECTION OF AUXILIARY BATTERY TYPE

 

Press the Mode button on the front panel until all Battery Chemistry LEDs are 
flashing. There are 4 battery chemistries available: Gel, AGM, Wet and Calcium. 
Keep pressing the button momentarily until the Battery Chemistry LED you want  
is flashing. After you release the button, your selection is entered and saved.  
Your selection will be restored automatically even after the IDC25 is fully 
disconnected and reconnected. The default Battery Chemistry is AGM. 

 

Charging profile for each selection:

  Bulk 

*Constant Current up to:

  *20A at 9-11Vdc,  

GEL 

AGM 

WET 

CALCIUM

    25A at 11-32Vdc 

14.1V 

14.4V 

14.7V 

15.4V

  Absorption   

Constant Voltage until current drop to 3.8A

  

GEL 

AGM 

WET 

CALCIUM

 

 

14.1V 14.4V  14.7V 15.4V

  Float 

Keep Constant Voltage at 13.7V 

  Equalisation 

3.8A Constant Current Charge up to 16V

  (Calcium mode Only)  

then hold for 1 hour (5 hour timeout)

 

Calcium Chemistry mode is good for charging Optima batteries or deeply discharged 
calcium-calcium lead acid batteries (e.g Delkor DC31). 

 

Please consult the battery manufacturer if you are unsure of your battery’s 
chemistry.

Содержание IDC25

Страница 1: ...25 Amp 3 Stage Switchmode INTELLI CHARGE DC SOLAR BATTERY CHARGER P No IDC25...

Страница 2: ...circuit FEATURES The IDC25 DC DC charger is purposely designed for charging auxiliary batteries It includes all the features needed to maintain the auxiliary battery to its optimum condition and to p...

Страница 3: ...ed with a 2 metre temperature sensor The sensor monitors the battery temperature and adjusts compensates the charger s output to prevent overcharging This is ideal for batteries used in warmer climate...

Страница 4: ...11Vdc 25A at 11 32Vdc Constant Current up to GEL AGM WET CALCIUM 14 1V 14 4V 14 7V 15 4V Absorption Constant Voltage until current drop to 3 8A GEL AGM WET CALCIUM 14 1V 14 4V 14 7V 15 4V Float Keep...

Страница 5: ...atus Solar LED Indicates solar input status Alternator LED Indicates alternator input status LED Battery Chemistry Display Indicates selected battery chemistry type DC Leads Temperature Sensing Cable...

Страница 6: ...used for cable extension Recommended cable size for wiring Cable Size Alternator Input Cable Red 8mm2 8 B S Solar Input Cable Green 8mm2 8 B S Output Cable Grey 8mm2 8 B S Common Ground Black 8mm2 8...

Страница 7: ...s close as possible to the Solar Panel positive terminal Then connect the Solar Panel negative terminal to the IDC25 Common Ground cable black colour Alternatively connect both Solar Panel negative te...

Страница 8: ...nected The default Battery Chemistry is AGM Charging profile for each selection Bulk Constant Current up to 20A at 9 11Vdc GEL AGM WET CALCIUM 25A at 11 32Vdc 14 1V 14 4V 14 7V 15 4V Absorption Consta...

Страница 9: ...rter Battery Red 8mm 2 Ground Chassis Black 8mm 2 Ignition override Blue 1 5mm 2 External LED Pink 1 5mm 2 Solar Green 8mm 2 Output Auxiliary Battery Grey 8mm 2 Temperature Sensing Black twin core Tem...

Страница 10: ...er Battery Red 8mm 2 Ground Chassis Black 8mm 2 Ignition override Blue 1 5mm 2 External LED Pink 1 5mm 2 Output Auxiliary Battery Grey 8mm 2 Temperature Sensing Black twin core Temp Sensor mount to ba...

Страница 11: ...dicator Earth Chassis Ground Chassis Black 8mm 2 External LED Pink 1 5mm 2 Solar Green 8mm 2 Output Auxiliary Battery Grey 8mm 2 Temperature Sensing Black twin core Temp Sensor mount to battery casing...

Страница 12: ...to the battery for long time Solid RED BLUE Output battery is reversely Check output cable Flashing Connected connection RED BLUE Overvoltage is detected Check auxiliary battery Flashing Flashing at o...

Страница 13: ...ates the auxiliary battery is in full charged Q I have connected the charger properly but the INPUT LED does not come on A Check the cable size The IDC25 is designed to power on and charge from an inp...

Страница 14: ...nough to ruin your battery If after twelve hours of charging your battery is still accepting charge you should test the cells using a hydrometer If one reading is lower than the rest it indicates a fa...

Страница 15: ...15 NOTES...

Страница 16: ...must deliver the product at their cost to the original place of purchase or to any other place which may be nominated by either BWI or the retailer from where the product was bought in order that a wa...

Отзывы: