Projecta IC1500L Скачать руководство пользователя страница 3

3

FEATURES

5 STAGE AUTOMATIC CHARGING

This is a fully automatic battery charger with 5 charge stages.
Automatic charging protects your battery from being overcharged so you can leave the 
charger connected to the battery indefinitely. 
5 stage charging is a very comprehensive and accurate charging technique that gives 
your battery longer life and better performance compared to using traditional chargers.
The 5 charge stages are:
Soft Start 1, Soft Start 2, Bulk, Absorption and Float.

VOLTAGE

CURRENT

(AMPS)

STAGE

1

2

4

5

3

SOFT START 1

Increases battery 

life by gently 

starting to charge 

the battery 

5% of bulk

SOFT START 2

Increases battery 

life by gently 

starting to charge 

the battery 25% 

of bulk

BULK CHARGE

Reduces charging 

time by delivering 

maximum charge 

to set voltage

ABSORPTION

Ensures a full 

charge to the 

battery without 

overcharging

FLOAT

Float charge 

maintains the 

battery at 100% 

charge

Soft Start 1

This is a preliminary charge that is for heavily discharged batteries where the voltage is 
between 2-8 Volts. Charge is limited to 5% of set current.

Soft Start 2

This is a preliminary charge that is for discharged batteries where the voltage is between 
8-10 Volts. Charge is limited to 25% of set current.

Bulk (Constant Current)

The Bulk stage reduces charging time by charging the battery at the maximum rate 
(constant current) to a set voltage, at which point the battery is approximately  
80% charged.

Absorption (Constant Voltage)

The absorption stage charges the battery to 100% by adjusting the charge rate allowing 
the battery to absorb more power. 

Float

The Float stage maintains the battery at 100% charge without overcharging or 
damaging the battery. This means the charger can be left connected to the battery 
indefinitely.

Содержание IC1500L

Страница 1: ...INTELLI CHARGE LITHIUM 12 VOLT 5 STAGE SWITCHMODE BATTERY CHARGER P No IC1500L...

Страница 2: ...ng rules Do not attempt to charge non rechargeable batteries Never charge a frozen battery If the AC cord is damaged do not attempt to use It must be replaced or repaired by a qualified person Corrosi...

Страница 3: ...ltage ABSORPTION Ensures a full charge to the battery without overcharging FLOAT Float charge maintains the battery at 100 charge Soft Start 1 This is a preliminary charge that is for heavily discharg...

Страница 4: ...page 13 Slow Flash Slow Flash CHARGING LED blue LED illuminates and flashes during charging process FULLY CHARGED LED green LED illuminates solid when fully charged POLARITY PROTECTION Prevents the ou...

Страница 5: ...nce from a remote control display allowing the charger to be flush or surface mounted out of the way and out of sight The battery charger and remote are synchronised for operation either locally or by...

Страница 6: ...nt until the battery reaches 8 0V Soft Start 2 Charge at 25 of set current until the battery reaches 10 0V Bulk Set current up to 14 5V Absorption Constant voltage of 14 5V until current drops to the...

Страница 7: ...Charged Mounting Flange Temperature Compensation Probe Adjustable Charge Rate Mode Button selects between CHARGE POWER SUPPLY LED s display if in CHARGE or POWER SUPPLY Power Cord DC Leads 7 222 108 6...

Страница 8: ...POWER ON CHARGE CHARGING FLOAT 15A 8A 4A 2A CHARGE RATE 12V15A5 Stage I N T E L L I C H A R G E Connection in vehicle negatively earthed STEP 1B CONNECTION IN VEHICLE Determine if the vehicle is Posit...

Страница 9: ...ert the data plug into the data socket at the rear of the battery charger Cable length 4 5 metres Warning Ensure the cable is secured safely away from moving parts Installing Temperature Sensor To ins...

Страница 10: ...e and the charger can be left connected to the battery without over charging If the POWER LED is flashing there is a fault refer to Fault Codes explanation on page 13 of this manual STEP 7 DISCONNECTI...

Страница 11: ...x ring terminals an inline fuse holder and a fuse with a rating equal to or greater than twice the chargers output See below IC1500L 30 Amp fuse Connection 1 Cut off the supplied battery clips ensure...

Страница 12: ...iances are drawing power from the battery for example like a Fridge Although the charger is designed to work with a battery connected it can also work without a battery LOCKING THE BATTERY CHARGER SET...

Страница 13: ...y has not reached 10 0V after 2 hours Battery may be faulty check the battery or try and charge again F03 Fast Flash ON Fast Flash Absorption has been charging for more than 20 hours and is now in flo...

Страница 14: ...er Supply mode you are able to use the charger as a power supply to run an appliance Ensure the appliance being run is not greater than the charger s output current and where possible connect the char...

Страница 15: ...ability to accurately measure the battery s response to the charge being applied The battery charger has been designed to accommodate this situation although not recommended For optimum charging it is...

Страница 16: ...rchase together with an explanation in writing as to the nature of the claim In the event that the claim is determined to be for a minor failure of the product then BWI reserves the right to repair or...

Отзывы: