![Projecta 9315219252555 Скачать руководство пользователя страница 4](http://html1.mh-extra.com/html/projecta/9315219252555/9315219252555_manual_1614096004.webp)
4
SPECIFICATIONS
Operating Conditions
Input Voltage
9-32Vdc
Maximum Solar Input Voltage
28Vdc
Maximum Input Current
65A
Input Current (No Load)
20mA
Back Drain on Auxiliary Battery
< 5mA
External LED Output – Constant Current
4mA
Output Current
Input 9–11Vdc: 37A
Input 11V-32dc: 45A
Input Fuse Rating
80A (Not supplied)
Output Fuse Rating
80A (Not supplied)
Maximum Output Power
693W
Solar Input Turn On Voltage
9V
Size
255 x 122 x 40 mm
Solar MPPT Voltage
17.5V
Weight
1.54kg
Operating Temperature (Derated from 55
o
C)
-10 to +80
o
C (Ambient Temperature)
Charge Control
Charge Type
3 Stage
Bulk *37A at 9-11Vdc and 45A at 11-32Vdc
*Constant Current up to:
GEL
AGM
WET
CALCIUM
14.1V 14.4V 14.7V 15.4V
Absorption
Constant Voltage until current drop to 7.5A
GEL
AGM
WET
CALCIUM
14.1V 14.4V 14.7V 15.4V
Float
Keep Constant Voltage at 13.7V
Equalisation
7.5A Constant Current Charge up to 16V
(Calcium mode only)
then hold for 1 hour (5 hour timeout)
Battery Range
Battery Capacity
150-600Ah
Type of Batteries Supported
GEL, AGM, WET & CALCIUM
Operating Mode
12V Vehicle
24V Vehicle
VSR Mode – Default (Ignition Override
Turn on
Turn off
Turn on
Turn off
Not Connected)
13.4-20V
<12.8V
26.8-32V
< 25.6V
Low Voltage Mode – Ignition Override cable
Turn on
Turn off
Turn on
Turn off
connected to ignition switch (ignition on)
12.2-20V
<11.9V
24.4-32V
<24V
Standards
EMC
C-Tick, AS/NZS CISPR11:2011 Class B
IP Rating
IP67