FEATURES

Industrial LED projector made with aluminum and plastic structure and glass 

lenses. The overall dimensions are between 190mm e 270mm (H) 110mm (L), 

110 mm (W).

• 

LED light source

• 

LED Colour BLUE, RED, GREEN or YELLOW

• 

Absorption 0,11A (MINI/MID SAFE EVO GREEN, BLUE, YELLOW), 0,09A 

(MINI/MID SAFE EVO RED) 

• 

Frequency: 50-60 Hz

• 

Input voltage From 90Vac to 305Vac

• 

Consumption 25W (MINI/MID SAFE EVO GREEN, BLUE, YELLOW), 20W 

(MINI/MID SAFE EVO RED)

• 

Appliance with isolation class I

• 

Max nominal ambient temperature: +50°C

• 

Min nominal ambient temperature: -40°C

• 

IP Protection class: IP54

• 

Use of heat-resistant power cables, interconnection cables or external 

wiring till +90°C

SAFETY RULES

Always switch off the fixture before carrying out any cleaning.

Before taking any action on it make sure it has completely cooled.

Fixture suitable for installation on normally inflammable surfaces.

Designed for direct illumination of horizontal and vertical surfaces.

LED light source: it is recommended not to fix the beam to avoid possible 

permanent damage to the retina.

Device with protection degree IP54 for indoor and outdoor use. The lamps of 

this device are not substitutable.

Electrical part consists of a stabilized power supply: builtin protection circuit 

shuts  down  the  device  in  case  of  open  circuit,  short  circuit,  overload  or 

overheating; the power supply may not be turned on even after the fault. In 

this case, contact the manufacturer.

Conductor cross section min. 1 mmq.

Operating temperature: min. -40°C max. +50°C.

The luminaire must be positioned in such a way that a prolonged observation 

of the luminaire is not possible at a distance of less than 3 meters.

Notes for the disposal of the device, see WEEE standards.

HOW TO USE

Open the box, extract the fixture carefully and store up the packaging.

After attaching the lamp on the ceiling or on the wall, using the brackets, 

connect the power cord.

The lamp has a 3x1mmq three-core cable at the output, to be connected to 

the power supply (220Vac). The connection must made in order to maintain 

the IP54 degree of protection of the appliance.

Do not cover the device with plastic sheets, cloths, tissues cause it has to 

dissipate the heat produced by the light source.

For cleaning and maintenance always use a damp cloth without any solvents 

or acids.

For your safety, do not attempt to modify the unit.

The information contained in the following documents are subject to change 

without any notice by the company.

The company guarantees the conformity of the products with the applicable 

European safety and EMC.

We accept no responsibility for any damage to the product, to things and/or 

people, due to improper installation and/or because of changes made to the 

device,  using  accessories  and/or  electrical/electronic  components  are  not 

suitable.

It’s  strictly  forbidden  any  reproduction,  even  partial,  of  the  information 

contained in this leaflet.

Содержание MINI SAFE EVO

Страница 1: ...MANUALE D USO USER MANUAL MINI MID SAFE EVO ...

Страница 2: ...i protezione IP54 per l utilizzo in ambienti interni Le lampade di questo dispositivo non sono sostituibili Sezione conduttori di alimentazione min 1mmq Temperatura di esercizio min 40 C max 50 C L apparecchio di illuminazione deve essere posizionato in modo che non sia prevista un osservazione prolungata dell apparecchio ad una distanza inferiore ai 3mt Note per lo smaltimento dell apparecchio ve...

Страница 3: ...er supply builtin protection circuit shuts down the device in case of open circuit short circuit overload or overheating the power supply may not be turned on even after the fault In this case contact the manufacturer Conductor cross section min 1 mmq Operating temperature min 40 C max 50 C The luminaire must be positioned in such a way that a prolonged observation of the luminaire is not possible...

Страница 4: ...f the Europen Union Apparecchio che può essere installato su superfici normalmente infiammabili Temperatura di funzionamento normale non superiore a 90 C Temperatura di funzionamento in caso di guasto non superiore a 130 C EN 60598 1 ED 2000 A11 2000 A12 2002 A1 2006 Fixture suitable for direct mounting on normally inflammable surfaces Normal operating temperature not exceeding 363K Temperature of...

Страница 5: ...ti illuminanti 3 metri Minimum distance from luminaires 3 meters Apparecchio non idoneo al montaggio diretto su superfici normalmente infiammabili idonei solo al montaggio su superfici non combustibili Appliance not suitable for direct mounting on surfaces normally flammable suitable only for surfaces non combustible Uso di cavi di alimentazione di interconnessione o di cablaggio esterno resistent...

Страница 6: ...nte a quanto previsto nelle Condizioni di Garanzia ricevute al momento dell acquisto e alle schede tecniche consultabili sul sito www progtech it Grazie per il vostro acquisto WARRANTY This is to certify that the product purchased has been made entirely in Italy by CABLOTECH using high quality materials and with the aid of specialized manufacturing it was finally subjected to a careful process of ...

Страница 7: ...PROGTECH srl via Milano 60 24040 Bonate Sopra Bg T 39 035 04 46 251 info progtech it www progtech it ...

Отзывы: