![Progressive Dynamics PD1200 Series Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/progressive-dynamics/pd1200-series/pd1200-series_installation-and-operation-manual_1613877013.webp)
13
Figure 19
Display Indicators
Display Interface
Select Button
Figure 17
Display Panel
Display
Power Button
Remote Display Port
Error Code Condition
Description
E-1
Low battery volt-
age detected
Input voltage has dropped beneath 10.5V for
several seconds. The PD1200 Series inverter
will automatically restart when the input
voltage reaches 12.0V.
E-2
High battery volt-
age shutdown
Input voltage has surpassed 15.5V. The
PD1200 Series inverter will automatically
restart when the input voltage falls below
15.0V.
E-3
AC output over-
load shutdown
Output power has surpassed the continuous
power limit or the peak power limit. The
PD1200 Series inverter will not automati-
cally restart. A manual restart is necessary
E-4
Over-temperature
shutdown
Internal temperature of the inverter has ex-
ceeded its safe operating limit. The PD1200
Series inverter will automatically restart
when internal temperatures return to safe
operating conditions.
ERROR CODES
E-5
Internal Error
An internal error has been detected. The
PD1200 Series inverter will not automati-
cally restart. A manual restart is necessary
Display Features
Power Button: Press to turn on; hold to turn off
Select Button: Cycles between display states:
Input Voltage, Output Voltage, Output
Power, Sleep, Error Code (if applicable)
Power Indicator: Lights up green when the inverter is on
Fault Indicator: Flashes red when an error has occurred
Shore Indicator: Lights up yellow when AC input is detected
Low Bat Warning Indicator: Lights up red when the battery
is nearing the end of its charge
Sleep: Lights automatically dim after 30 seconds
Remote port for externally mounted display
Figure 16
Inverter Display Location
Display Panel
Figure 14
Error Code Descriptions
Figure 18
Remote Display (optional)
Rear Remote Connection
NOTE:
For all error codes consult page 16 in the Installation and Opera-
tion Guide for troubleshooting methods
NOTE:
Remote display operates exactly the same as the dis-
play mounted to the inverter
Power Indicator
Shore Power Indicator
Low Bat Warning Indicator
Fault Indicator