Progressive Dynamics Inteli Power 9200 PD9200 SERIES Скачать руководство пользователя страница 2

FEATURES 

 

INTEGRATED CHARGE WIZARD

 ... The INTELI-POWER 9200 Power Converter is the intelligent way to 

charge your RV battery.  The built-in Charge Wizard

®

 microprocessor constantly monitors the battery voltage then 

automatically adjusts the converter output voltage to provide the proper charging voltage for fast recharges and 
long-term maintenance. 
 

MULTIPLE BATTERY CHARGING

 ... INTELI-POWER 9200 has the capability of charging multiple batteries 

at the same time!  They can even charge a combination of different capacity batteries. 
 

GFCI PROTECTION

 ... INTELI-POWER 9200 has the LOWEST ground fault leakage. With this unit, the user 

can confidently utilize the RV's AC outlets without being concerned about a ground fault interruption of the 
facilities power source. 
 

REVERSE BATTERY PROTECTION CIRCUIT

 ... If a battery is accidentally hooked up backwards, the 

converter will be protected. Externally mounted ATC type fuses will blow when a battery is connected in reverse. 
Replace with same type and rating. 
  

CAUTION 

IF THE REVERSE BATTERY PROTECTION FUSES ARE BLOWN DURING INSTALLATION, CHECK 
TO SEE THAT THE BATTERY HAS BEEN CONNECTED PROPERLY BEFORE REPLACING THE 
FUSES. REPLACE THE FUSES ONLY WITH THE SAME TYPE AND RATING AS THE ORIGINAL 
FUSES.  USING OTHER FUSES COULD RESULT IN THE CONVERTER BEING DAMAGED, 
VEHICLE DAMAGE, INJURY OR OTHER CONSEQUENCES (SEE WARRANTY). 

 

SHORT CIRCUIT PROTECTION

 ... The "smart" converter, INTELI-POWER 9200, senses, within millionths of 

a second, if the output terminals have been shorted.  If this condition should occur the converter first limits the 
current.  Should the condition continue to exist the converter then reduces the current output, within thousandths of a 
second.  The INTELI-POWER 9200 was designed to protect itself.  Once the "short circuit" has been corrected the 
INTELI-POWER 9200 will automatically return to normal operating conditions. 
 

THERMAL PROTECTION

 ... If an over temperature condition should occur due to air flow obstruction or 

improper installation, the INTELI-POWER 9200 senses the condition and decreases power output until the unit 
returns to normal operating temperature.  The converter will return to full output capacity as it cools down. 
 

IGNITION PROTECTION

 ... All INTELI-POWER 9200 series converters are ignition protected. 

 

INTERNAL COMPONENT COOLING

 ... The INTELI-POWER 9200 series of converters are equipped with a 

variable speed cooling fan.  The fan will only run at the speed needed to prevent the converter from overheating and 
shutting down.  Running the fan at lower speeds where possible will reduce the audible noise generated by the fan 
while protecting the converter from excess heat. The location of the fan allows for the maximum cooling of both the 
case and components. 
 

 

OVERVOLTAGE PROTECTION 

... If the Input Voltage exceeds a preset limit the converter will shutdown to 

prevent damage.  The unit will return to normal operation when the voltage returns to normal 
 
The INTELI-POWER series of power converters have undergone tens of thousands of hours of strenuous 
engineering testing to insure years of trouble free operation. These converters have been designed and tested to 
provide maintenance free operation.   

Содержание Inteli Power 9200 PD9200 SERIES

Страница 1: ...OF ENJOYMENT OR OTHER INCIDENTAL DAMAGES ARISING OUT OF THE USE OF OR INABILITY TO USE THE PRODUCT THIS INCLUDES DAMAGES TO PROPERTY AND TO THE EXTENT PERMITTED BY LAW DAMAGES FOR PERSONAL INJURY THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE IV PROOF OF PURCHASE A warranty claim must be accompanied by proof of ...

Страница 2: ...ls have been shorted If this condition should occur the converter first limits the current Should the condition continue to exist the converter then reduces the current output within thousandths of a second The INTELI POWER 9200 was designed to protect itself Once the short circuit has been corrected the INTELI POWER 9200 will automatically return to normal operating conditions THERMAL PROTECTION ...

Страница 3: ...s 14 4 Volts Boost Mode Returned the battery to 90 of full charge in approximately 8 hours The battery reached full charge in approximately 11 hours 13 6 Volts Normal Mode Required 40 hours to return the battery to 90 of full charge and 78 hours to reach full charge 13 2 Volts Storage Mode Required 60 hours to return the battery to 90 of full charge and 100 hours to reach full charge The integrate...

Страница 4: ... mode the microprocessor automatically increases the output voltage to 14 4 volts for 15 minutes every 21 hours This will help to reduce the buildup of sulfation on the battery plates NOTE Your Inteli Power 9200 Converter Charger may have been supplied with a Remote Pendant The Remote Pendant is optional on OEM units but is included with all retail models and plugs into the accessory port of the 9...

Страница 5: ...hort Circuit Trace RV Circuits for possible fault Unit has shutdown due to overheating Check air flow Allow unit to cool Check input voltage Converter will shut down if the input voltage exceeds 132 Volts Unit has shutdown due to over voltage Also see Item 5 below Correct Input Voltage 2 External Fuses Blown Reverse Battery Hook Up Correct Hook up and replace Fuses with same type and rating 3 Conv...

Страница 6: ...x 8L x 9W Weight 5 8lbs PD9270 Input 105 130 VAC 60 Hz 1250 Watts Output 13 6 VDC 70 Amps Dimensions 3 6H x 8L x 9W Weight 5 8lbs PD9280 Input 105 130 VAC 60 Hz 1300 Watts Output 13 6 VDC 80 Amps Dimensions 3 6H x 11 5L x 9W Weight 7 5lbs CAUTION RISK OF FIRE Chassis bonding wire must be a separate wire ran directly from the Grounding Lug provided on the converter DO NOT connect Output Negative to...

Страница 7: ...tilisation DE PLAISIR OU D Autres DOMMAGES DE CHOSE FORTUITE PROVENANT DE L Utilisation DE OU DE L Incapacité D UTILISER LE PRODUIT CECI INCLUT DES DOMMAGES À LA PROPRIÉTÉ ET JUSQU AU DEGRÉ AUTORISÉ PAR LA LOI AUX DOMMAGES POUR DES BLESSURES CETTE GARANTIE EST AU LIEU DE TOUTES AUTRES GARANTIES Y COMPRIS LES GARANTIES IMPLICITES DE LA VALEUR MARCHANDE ET DE LA FORME PHYSIQUE POUR UN BUT PARTICULIE...

Страница 8: ...on de l obstruction de circulation d air ou d une inexacte installation d Inteli power 9200 diminuer la sortie reviendra en même temps que l unité revienne à la température de fonctionnement normale La pleine capacité de sortie retournera comme l unité refroidit REFROIDISSEMENT DE COMPOSANT INTERNE Les INTELI POWER séries de convertisseurs sont équipés d un ventilateur de vitesse variable Le venti...

Страница 9: ...RÉGULIÈRE QUAND LE CHARGEUR DE BATTERIE EAT CONSTAMMENT COMMECIE À UNE SOURCE D ENERGIE CELUI CI SE DECHARGECA DU GAZ ET PERDRA DU FLUIDE MODE DE NORMALE La tension de rendement a placé à 13 6 volts de C C Cette tension fournit bon chargeant des taux et la basse utilisation de l eau MODE DE POUSSÉE Si le convertisseur sent que la tension de batterie a chuté au dessous de l préréglez de niveau la t...

Страница 10: ...arge complètement la batterie en toute sécurité Lumière Clignotant Lentement toutes les 5 6 secondes Indique que le convertisseur est en Storage Mode mode de charge complète et que la tension de sortie est baissée à 13 2 Dans ce mode la batterie RV véhicule de caravaning charge entièrement et elle est maintenue à son niveau de charge maximum INTERRUPTEUR MANUEL L interrupteur manuel a été fourni p...

Страница 11: ...on appropriée Vérifiez le renversement de la polarité Fusibles Externes Soufflés Par remplacez les fusibles par le même type et calibre Court circuit Circuits de la trace RV pour possibité le défaut L unité a l arrêt dû à la surchauffe Contrôlez la circulation d air Permettez à l unité de se refroidir Contrôlez la tension d entrée 1 Aucune Sortie L unité a s arrêt dû à une sur tension voir égaleme...

Страница 12: ...imensions 3 6H x 8L x 9W Poids 5 8lbs PD9280 Entrée 105 130 VAC 60 Hz 1300 Watts Sortie 13 6 VDC 80 Ampères Dimensions 3 6H x 11 5L x 9W Poids 7 5lbs LE RISQUE DE PRUDENCE DE FEU le Châssis adhéérer le fil doit être un fil séparé a couru directement au châssis de la Patte de mise à terre fournie sur le côté du convertisseur Ne pas connecter le Production négatif à l utilisation de châssis fil pare...

Отзывы: