background image

Problem 

Possible Cause 

Corrective Action

Low power mode 

activated

 Press any button on the remote and LED will activate.

Connection issue

 Disconnect and reconnect the RJ-45 remote connector. Ensure connection is 
secure and cable is not damaged.

Limit switch reached 

Follow "Setting Limit Switches" instructions to remove the programmed limit. If 
maximum or minimum height limit has been reached, please move the system 
in the opposite direction.

Connection issue

Disconnect and reconnect the Lifting Columns, Control Box, AC Power, and 
Remote.

Table lift travels at a 

significantly slower 

speed than rated 

specification.

Weight issue

Ensure weight capacity has not exceeded the maximum load rating.

Unusual noise during 

travel.

Weight issue

Ensure weight capacity has not exceeded the maximum load rating.

Table lift stops abruptly 

during travel.

Obstacle

Ensure there are no obstacles in the path of the table lift. If the movement 
continues to fail, initiate the Reset Procedure.

Table lift is not level.

Out of sync

Disconnect and reconnect all cables (Lifting Column, Control Box, AC Power, 
and Remote), then initiate the Reset Procedure.

Troubleshooting Guide

Remote LED is off.

Table lift does not 

move when motion 

control buttons are 

pressed. 

Error Code

Error Summary

Description

E01

M1 overcurrent protection

E02

M2 overcurrent protection

E03

M3 overcurrent protection

E04

M4 overcurrent protection

E07

M1 hall error

E08

M2 hall error

E09

M3 hall error

E10

M4 hall error

H01

Over heat /duty cycle 

protection

All columns stop moving, remote displays H01 (if LED screen available). Allow 
the system to rest for 16 minutes, use normally. Follow the Duty Cycle rating to 
ensure no issues arise from overheating.

Error Codes (remotes with LED display)

All columns stop moving and remote displays E01-E04. Ensure that the total 
weight capacity of the table lift has not been exceeded and that no obstacles 
obstruct the movement. Press any key and remote will display
RST, initiate the Reset Procedure. If the issue persists, disconnect and 
reconnect all of the lifting columns, including the main power. Repeat the Reset 
Procedure.

All columns stop moving and remote displays E07-E10. Ensure that all columns 
are still properly connected to the control box. Check to see if any cables have 
been damaged. Press any key and remote will display RST, initiate the Reset 
Procedure. If the issue persists, disconnect and reconnect all of the lifting 
columns, including the main power. Repeat the Reset Procedure.

Troubleshooting

8

Содержание flt-05

Страница 1: ...Contents Caution Specifications Dimensional Drawing Components Assembly Operation Reset Procedure Troubleshooting 1 2 3 4 5 6 7 7 8 FLT 05 User Manual...

Страница 2: ...risk of injury and electric shock During the Reset Procedure the table lift will retract 7mm below the lowest normal operating height ensure no obstacles impede this motion of travel Keep all electri...

Страница 3: ...against obstacles which impede the motion of travel There are 3 force settings which can be detected during travel 22lbs 33lbs and 44lbs Input Voltage 120VAC 60 Hz Output Voltage 24VDC Stroke movemen...

Страница 4: ...Feet and column style may vary slightly Dimensional Drawing 3 Extended 49 0 Retracted 23 5 Maximum Width 72 6 Minimum Width 42 7 27 6 1 3 3 1 2 8 2 0 22 6 1 7...

Страница 5: ...rame 2 Side Bracket Frame 3 Foot Ceter Rail Caster Leg Cable Clip ST5x16 Wood Screw ST5x20 Wood Screw M6x10 Machine Screw M6x14 Machine Screw Control Box Cable 1 3m Power Cord Handset Qty 12 1 1 3 2 3...

Страница 6: ...he two holes in the top of the side bracket going into the frame end Using the supplied Allen Wrench rotate each screw just a few turns After both machine screws are inserted tighten them both Do the...

Страница 7: ...e and turn it right side up STEP 9 Plug the Power Cord 17 into a 110V outlet and plug in all three cables from the Legs into the Control Box Use the two Cables 16 for the two farthest legs It is now r...

Страница 8: ...a numbered button The LED display will flash an S followed by an S Number This will indicate that the preset has been saved To use a preset press any of the numbered buttons and the table lift will be...

Страница 9: ...e Remote LED is off Table lift does not move when motion control buttons are pressed Error Code Error Summary Description E01 M1 overcurrent protection E02 M2 overcurrent protection E03 M3 overcurrent...