Progress Replacement Motion Sensor P6036 Скачать руководство пользователя страница 3

--

598-1280-00

Motion

 Least Sensitive 

Most Sensitive

Sensor

Motion

The sensor is less sensitive to motion directly towards 
it, most sensitive to motion across its field of view.

 

Maximum Range 

Maximum  

 

 

 

Coverage Angle

8 ft. 

(2.4m)

70 ft. 

(21m)

TEST AND ADJUSTMENT

 

Turn  on  the  circuit  breaker  and  light 
switch.

NOTE:

  Sensor  has  a  1 

1

/

2

  minute  calibration 

period before it will detect motion. When 
first turned on, wait 1 

1

/

2

 minutes.

RANGE

10 5 1 TEST

ON-TIME

Bottom of Sensor

Avoid aiming the control at:

•  Objects that change temperature rapidly, such 

as 

heating vents and air conditioners.

 These 

heat sources could cause false triggering.

•  Areas where 

pets or traffic

 may trigger the control.

•  

Nearby large, light-colored objects

 reflecting 

light may trigger the shut-off feature. Do not point 
other lights at the sensor.

MIN 

MAX

180°

  Loosen the clamp screw 

in the sensor ball joint and 
gently rotate the sensor.

  Walk  through  the  cover-

age  area  noting  where 
you  are  when  the  lights 
turn on (also, the LED will 
flash  several  times  when 
motion is detected). Move 
the sensor head up, down, 
or sideways to change the 
coverage area. 

Keep the 

sensor at least 1" (2.5 cm) 
away from the lamps.

  Adjust  the  RANGE  as 

needed. RANGE set too 
high  may  increase  false 
triggering.

 

Secure the sensor head 
by tightening the clamp 
screw.

 Do not overtighten the screw.

  Set the amount of TIME you want the lights to stay 

on after motion is detected (1, 5, or 10 minutes).

Warning - Risk of fire. Do not aim the lamps 
at a combustible surface within 3 ft. (1 m).

SPECIFICATIONS

Range . . . . . . . . . . . . . . Up to 70 ft. (21 m) [varies with 

surrounding temperature].

Sensing Angle . . . . . . . . Up to 180°
Electrical Load . . . . . . . . Up to 500 Watt (4.2A) Maximum 

Incandescent [Up to 250 Watt 
maximum each lamp holder.]

Power Requirements . . . 120 VAC, 60 Hz
Operating Modes . . . . . . TEST,  AUTO,  and  MANUAL 

MODE

Time Delay  . . . . . . . . . . 1, 5, 10 minutes
Range . . . . . . . . . . . . . . Adjustable

  Turn the RANGE control to the mid position and 

the ON-TIME control to the TEST position.

Clamp 
Screw

Ball 
Joint

Aim Sensor 

Down for Short 

Coverage

Aim Sensor 

Higher for Long 

Coverage

Отзывы: