Periodic maintenance
Periodically speak your local Service Force
Centre to check the conditions of the gas
supply pipe and the pressure adjuster, if fit-
ted.
WHAT TO DO IF…
Problem
Possible cause
Remedy
There is no spark when lighting
the gas
• There is no electrical supply
• Make sure that the unit is
connected and the electrical
supply is switched on.
• Control the fuse. If the fuse is
released more than one time,
refer to a qualified electrician.
• Burner cap and crown are
placed uneven
• Make sure that the burner
cap and crown are in correct
positions.
The flame is blow out immedi-
ately after ignition
• Thermocouple is not heated
sufficient
• After lightning the flame,
keep the knob pushed for
approximately 5 seconds.
The gas ring burns unevenly
• Burner crown is blocked with
food residues
• Make sure that the injector is
not blocked and the burner
crown is clear of food parti-
cles.
If there is a fault, first try to find a solution to
the problem yourself. If you cannot find a
solution to the problem yourself, speak your
dealer or the local Service Force Centre.
If you operated the appliance incorrect-
ly, or the installation was not carried
out by a registered engineer, the visit
from the customer service technician or
dealer may not take place free of
charge, even during the warranty peri-
od.
Labels supplied with the accessories
bag
Stick the adhesive labels as indicated be-
low:
MOD.
PROD.NO.
SER.NO
DATA
MOD.
PROD.NO.
SER.NO
DATA
MODEL
MODEL
MOD.
PROD.NO.
SER.NO.
03 IT
MADE IN ITALY
TYPE
230V-50Hz
IP20
0049
1
2
3
1
Stick it on Guarantee Card and send
this part
progress
21
Содержание PAG7530E
Страница 46: ...46 progress...
Страница 47: ...progress 47...
Страница 48: ...www progress hausgeraete de 397182201 B 212012...