background image

Assembly & Installation Instructions

Read instructions carefully and turn electricity off at main

circuit breaker panel before beginning installation.

CAUTION:

PAGE 1 of 4

Assembly & Installation Instructions

Read instructions carefully and turn electricity off at main

circuit breaker panel before beginning installation.

CAUTION:

P831-AT

PAGE 1 of 4

 

WARNING: 

When using special control devices with this fixture, follow instructions carefully to ensure N.E.C. 

compliance. For more help, contact a qualified electrical contractor. 

 
WARNING

:  This  product  contains  chemicals  known  to  the  State  of  California  to  cause  cancer,  birth  defects 

and/or other reproductive harm. Thoroughly wash your hands after  installing, handling, cleaning, or otherwise 
touching this product. 

 
WARNING: 

To complete the installation, choose only UL listed Progress trims from the label inside the 

housing. The use of any trim not listed in this fixture is a violation of N.E.C. article 110-3(B) and voids all 
warranties.

 

 
WARNING: 

Thermal insulation may be installed in direct contact with the fixture, but DO NOT install insulation 

in excess of eight inches deep above fixture. Greater depth may cause the thermal protector to cycle the fixture 
on and off. 
 

WARNING: 

National Electrical Code, Article 110-3 (b), states that “Listed or labeled equipment shall be used or 

installed in accordance with any instructions included in the listing or labeling”. Use only Progress UL listed 
trims. Use of other trims not listed in this fixture, including those that are UL classified, is a violation of N.E.C. 
110-3 (b) and voids all warranties. 

 
1. For Wooden Joists: Extend the Bar Hangers (6), use joist alignment tabs (4) to locate fixture and position 
underneath support joist (8). Drive the 4 Nails (7) into Joists (8) (Fig. 1). Drive additional nails through holes in 
Bar Hanger for alternate support if required.  
 
2. For Suspended Ceilings: Place the Fixture on the ceiling grid with the "T" Bars (9) running through the Bar 
Hanger Notches (10). Using a flat head screwdriver or other tool, bend the integral t-bar mounting tabs (11) 
downward to a vertical position (Fig. 3). Secure housing to the support structure with tie wire (supplied by 
others) in the holes supplied. Sheetmetal screws (supplied by others) can also be used in the holes supplied 
(20). (Fig. 2 & 3) 
 
3. Locate Housing along Bar Hanger in desired position and, using pliers, squeeze the 4 Locking Tabs (12) on 
the Plaster Frame (13) tightly over the Bar Hangers to prevent further Housing movement.  Screws (1) are 
provided that can be tightened to lock Housing on the Hanger Bars. 
 
4. As desired, hanger bars (6) may be shortened at score mark to fit tight mounting conditions and joist 
alignment tabs removed to adjust vertically as needed by breaking off with pliers. 
 
5. Unsnap Junction Box Cover (14) by lifting the Leaf Spring (24). (Fig. 6) 
 
6. Run supply wires through UL Listed connectors (not supplied) in one of the five Pryouts (15) on the Junction 
Box (16) or Type NM cable (ROMEX) through an Opening above the Wire Retaining Plate (17). Connect 
Supply Wires (19) as shown in (Fig 4 & 5). Replace Cover. 
 
7. FOR AIR-TIGHT APPLICATIONS: This Progress product is Air-Tight approved per ASTM E283 testing 
standards and complies with Washington State Energy Code Requirements. To complete the installation of this 
Air-Tight product, the opening between the housing (3) and drywall ceiling (22) must be sealed by the installer 
using silicone caulking, tape, or any other means acceptable to the local codes official. Progress Lighting 
Gasket Kit P8588-01 (purchased separately) can be used for this purpose (Fig. 6). 
 
8. Select a Trim from the Wattage Label inside the Housing. Use Only Lamp Types approved for the Trim 
chosen. 

DO NOT EXCEED MAXIMUM LISTED WATTAGE(S)

! For trim installation, refer to trim installation 

instructions. 
 
9. To gain access to junction box (16) after ceiling is finished, remove screw (2) and access door (5) inside of 
fixture. Junction box cover plate (14) can now be removed for service (Fig. 6). 
 

SOCKET CAP AND INSTRUCTION SHEET MUST BE REMOVED FROM FIXTURE PRIOR TO 

ENERGIZING. 

 

Содержание P831-AT

Страница 1: ...th the T Bars 9 running through the Bar Hanger Notches 10 Using a flat head screwdriver or other tool bend the integral t bar mounting tabs 11 downward to a vertical position Fig 3 Secure housing to the support structure with tie wire supplied by others in the holes supplied Sheetmetal screws supplied by others can also be used in the holes supplied 20 Fig 2 3 3 Locate Housing along Bar Hanger in ...

Страница 2: ...os Coloque la luminaria en el techo de modo que las barras en forma de T 9 pasen por las muescas de las barras de suspensión 10 Usando un destornillador con cabeza plana u otra herramienta doble las lengüetas de montaje de las barras T 11 hacia abajo llevándolas a una posición vertical Figura 3 Usando el alambre provisto por terceros fije el alojamiento a la estructura de soporte donde están los a...

Страница 3: ...ur ajustement verticalement 2 Pour plafonds suspendus Placer le dispositif d éclairage sur l armature du plafond de manière que les barres en T 9 pénètrent les encoches sur les barres de suspension 10 À l aide d un tournevis à tête plate ou autre outil plier les languettes de montage sur les barres en T vers le bas en position verticale La Figure 3 Fixer le boîtier à la structure de support inséra...

Страница 4: ...5 16 8 2 19 16 15 17 FIG 2 FIG 6 FIG 1 P8588 01 FIG 4 FIG 5 5 16 3 22 12 13 10 11 7 20 9 SUMINSTRO BLANCO ALAMBRE DEL ALAMBRE DE TIERRA VERDE O NEUTRO SUMINSTRO NEGRO ALAMBRE DEL DEL SUMINISTRO ALAMBRE DE TIERRA VERDE O NEUTRO DE LA LAMPARA DE LA LAMPARA O IDENTIFICADO O NEUTRO CONECTADOR DE LA LAMPARA ALAMBRE NEGRO UL CALIFICADO ALAMBRE BLANCO BLANC OU IDENTIFIABLE FILS DE CONNECTEUR SANS MARQUES...