Progress Lighting AirPro P2560 Скачать руководство пользователя страница 11

Attaching the Fan 

Blades

1.  Align the holes in the strength plate and 

holes in the blade with holes in the blade 

arm and secure with the screws provided 

(Figure 12).

2.  Repeat for the remaining blades. 

Figure 12

Figure 13

Blade Balancing

All blades are grouped by weight. Because 

natural woods vary in density, the fan may 

wobble even though the blades are weight 

matched.
The following procedure should correct most 

fan wobble. Check after each step.
1.  Check that all blade screws are secure.
2.  Most fan wobble problems are caused 

when blade levels are unequal. Check this 

level by selecting a point on the ceiling 

above the tip of one of the blades. Measure 

from a point on the center of each blade 

to the point on the ceiling. Measure this 

distance as shown in Figure 13. Rotate 

the fan until the next blade is positioned 

for measurement. Repeat for each blade. 

Measurements deviation should be within 

1/8”. Run the fan for 10 minutes.

Touching

Ceiling

STANDARD CEILING MOUNTING

1.  Align the locking slots of the ceiling 

canopy with the two screws in the 

mounting plate. Push up to engage the 

slots and turn clockwise to lock in place. 

Immediately tighten the two mounting 

screws firmly.

2.  Install the remaining two mounting screws 

into the holes in the canopy and 

tighten firmly.

3.  Install the decorative canopy ring by 

aligning the ring’s slots with the screws in 

the canopy. Rotate the ring clockwise to 

lock in place.

4.  You may now proceed to attaching the 

fan blades.

3.  Make sure that canopy is tightened securely 

to ceiling mounting bracket and that the 

ceiling mounting bracket is tightened 

securely to the electrical box.

4.  Interchanging two adjacent blades can 

redistribute the weight and possibly result 

in the smoother operation.

5.  Use the enclosed Blade Balancing Kit if the 

blade wobble is still noticeable.

8. Finishing the Fan Installation

Strength plate

Blade

Blade arm

Screws

Connecting the Safety 

Cable

Turn the wood screw (not provided) into the

1.

ceiling.

Place the looped end of the safety cable onto 

2.

the wood screw and then tighten the screw firmly,

or connect the safety cable directly to the outer joist.

Содержание AirPro P2560

Страница 1: ...P2560 93089915_A...

Страница 2: ...rst 30 days for replacement After 30 days the original purchaser MUST contact Progress Lighting at 864 678 1000 for repair or replacement which shall be determined in Progress Lighting s sole discreti...

Страница 3: ...lling Your Fan Setting the Codes on Remote Control and Receiver Making the Electrical Connections Finishing the Fan Installation Operating Your Fan Care of Your Fan Troubleshooting Specifications Tabl...

Страница 4: ...electrical connections spliced conductors should be turned upward and pushed carefully up into electrical box The wires should be spread apart with the grounded conductor and the equipment grounding c...

Страница 5: ...7 Switch Cup 8 Blade 5 9 Transmitter and Receiver 1 Mounting Bracket inside canopy 2 8 Ball Downrod Assembly hanger pin and locking pin pre attached 3 Canopy with Canopy Ring attached 4 Decorative Mo...

Страница 6: ...l box Note You may need a longer downrod to maintain proper blade clearance when installing on a steep sloped ceiling The maximum angle allowable is 20 If the canopy touches downrod remove the decorat...

Страница 7: ...s are on top Route the wires through the canopy and then through the ball downrod assembly Figure 7 Remove Loosen but Do Not Remove Turn Canopy Ring to Remove Figure 5 Figure 6 5 Loosen but do not rem...

Страница 8: ...he two screws provided with the outlet box If necessary use leveling washers not included between the mounting bracket and the outlet box Note that the flat side of the mounting bracket is toward the...

Страница 9: ...rtment in the back side of the transmitter B Slide code switches to your choice of up or down position factory setting is up C Replace the battery cover on the battery compartment of the transmitter 2...

Страница 10: ...Remote control model UC7067RYE 7 Making the Electrical Connections IF OTHER FAN OR SUPPLY WIRES ARE DIFFERENT PLEASE HAVE THIS UNIT INSTALLED BY A LICENSED ELECTRICIAN Follow the steps below to conne...

Страница 11: ...ING MOUNTING 1 Align the locking slots of the ceiling canopy with the two screws in the mounting plate Push up to engage the slots and turn clockwise to lock in place Immediately tighten the two mount...

Страница 12: ...g in the switch cup with the molded adaptor plug of the fan motor assembly Figure 15 4 Attach the switch cup to the fan by aligning the three screws holes on switch cup with the screw holes on the swi...

Страница 13: ...ling effect as shown in Figure 18 This allows you to set your air conditioner on a higher setting without affecting your comfort Cool weather Reverse An upward air flow moves warm air off the ceiling...

Страница 14: ...TION MAKING ELECTRICAL CONNECTIONS Fan will not start Fan sounds noisy 1 Check main and branch circuit fuses or breakers 2 Check line wire connections to the fan and switch wire connections in the swi...

Страница 15: ...guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipm...

Отзывы: