Progress Lighting AirPro P250009 Скачать руководство пользователя страница 7

4.

Hanging the Fan

REMEMBER

 to turn off the power. Follow 

the steps below to hang your fan properly.
NOTE: This fan is recommended for 

standard ceiling mount using the downrod 

provided with this fan. When using standard 

ceiling installation with the 6 inch downrod 

provided, the distance from the ceiling 

to the bottom of the fan blades will be 

approximately 14 inches.

Standard Ceiling Mounting

1.  Remove the canopy ring from the canopy 

by turning the ring counter-clockwise 

until it unlocks. (Figure 5)

2.  Remove the mounting bracket from the 

canopy by loosening the four screws on 

the top of the canopy. Remove the two 

non-slotted screws and loosen the slotted 

screws. This will enable you to remove 

the mounting bracket. (Figure 6)

3.  Remove the hanger pin and locking pin 

from downrod assembly.

4.  Route the wires exiting the top of the fan 

motor through the decorative motor collar 

cover then the canopy ring. Make sure the 

slot openings are on top. Route the wires 

through the canopy and then through the 

ball/downrod assembly. (Figure 7)

Remove

Loosen but Do Not Remove

Turn Canopy Ring to Remove

Figure 5

Figure 6

5.  Loosen, but do not remove, the set  screws 

on the collar on the top of the motor 

housing.

6.  Align the holes at the bottom of the 

downrod with the holes in the collar on top 

of the motor housing. (Figure 7) 

Carefully insert the hanger pin through the 

holes in the collar and downrod. Be careful 

not to jam the hanger pin against the wiring 

inside the downrod. Insert the locking pin 

through the hole near the end of the bolt 

until it snaps into its locked position, as 

noted in the circle inset of Figure 7.

7.  Re-tighten the set screws on the collar on 

top of  the motor housing.

8.  Make sure the grommet is properly installed 

in the collar cover, then slide the collar cover 

on the downrod until it rests on the motor 

housing. Be sure that the canopy and the 

collar cover are both oriented correctly.

9.   Proceed to “Installing the Fan” section.

FAILURE TO PROPERLY INSTALL SET SCREWS 

AS NOTED IN STEP 7 COULD RESULT IN FAN 

LOOSENING AND POSSIBLY FALLING.

Figure 7

Motor collar

Pin in locked

position

Locking pin

Tighten

screws

Hanger pin

Motor collar

cover

Canopy ring

Motor wires

Ball/Downrod

assembly

Canopy

Содержание AirPro P250009

Страница 1: ...P250009...

Страница 2: ...irst 30 days for replacement After 30 days the original purchaser MUST contact Progress Lighting at 864 678 1000 for repair or replacement which shall be determined in Progress Lighting s sole discret...

Страница 3: ...Safety Rules Unpacking Your Fan Installing Your Fan Making the Electrical Connections Operating Your Fan Care of Your Fan Troubleshooting Specifications Table of Contents 1 2 3 6 11 12 12 13...

Страница 4: ...ors should be turned upward and pushed carefully up into electrical box The wires should be spread apart with the grounded conductor and the equipment grounding conductor on one side of the electrical...

Страница 5: ...er and Receiver 11 Extension Lead Wire 1 Mounting Bracket inside canopy 2 6 Ball Downrod Assembly hanger pin and locking pin pre attached 3 Canopy with Canopy Ring attached 4 Decorative Motor Collar C...

Страница 6: ...rical box Note You may need a longer downrod to maintain proper blade clearance when installing on a steep sloped ceiling The maximum angle allowable is 20 If the canopy touches downrod remove the dec...

Страница 7: ...downrod assembly Figure 7 Remove Loosen but Do Not Remove Turn Canopy Ring to Remove Figure 5 Figure 6 5 Loosen but do not remove the set screws on the collar on the top of the motor housing 6 Align...

Страница 8: ...n assembly up to the ceiling mounting bracket Make sure the tab on the mounting bracket is properly seated in the groove in the hanger ball Figure 9 Figure 8 WHEN USING THE STANDARD BALL DOWNROD MOUNT...

Страница 9: ...provided by connecting the molded adaptors together Figure 12 BLUE BLUE BLACK WHITE WHITE Remote Receiver WHITE L N BLACK GREY BROWN BLUE BROWN GREY GREEN WHITE WHITE BLUE BLUE SUPPLY CIRCUIT Installi...

Страница 10: ...aligning the ring s slots with the screws in the canopy Rotate the ring clockwise to lock in place 4 You may now proceed to attaching the fan blades WHEN USING THE STANDARD BALL DOWNROD MOUNTING THE...

Страница 11: ...e from a point on the center of each blade to the point on the ceiling Measure this distance as shown in Figure 14 Rotate the fan until the next blade is positioned for measurement Repeat for each bla...

Страница 12: ...ssembly to the wires from the fan motor assembly by connecting the molded adaptor plugs together Carefully tuck all wires and splices into the switch cap Figure 16 4 Push the light kit fitter assembly...

Страница 13: ...itch or breaker box 5 Return power to the fan at the wall switch or breaker box 6 Press and release the Learn button located in the remote s battery compartment within 30 seconds of turning on the pow...

Страница 14: ...hour run timer While the fan is on press 8h turns on an 8 hour run timer Forward Reverse Changes direction of ceiling fan Breeze Press and release this button to enable the Breeze function this will c...

Страница 15: ...TION MAKING ELECTRICAL CONNECTIONS Fan will not start Fan sounds noisy 1 Check main and branch circuit fuses or breakers 2 Check line wire connections to the fan and switch wire connections in the swi...

Страница 16: ...ntee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment o...