Progres AMBITROL 100 Скачать руководство пользователя страница 3

 

3

F1: 

Programmes 

F2: 

Curves 

 

F3: 

Record 

F4: 

Anomalies 

 

F5: 

Configuration 

F6: 

Miscellaneous 

 

To choose a FUNCTION, press its 

corresponding number and "ENTER". When pressing 
the number you acced to directly to one of the three 
above seen screens (the screen also changes with the 
key "FUN"). 
 

DESCRIPTION OF THE FUNCTIONS 

 

PROGRAMMES 

With this function you access to the most 

important data of every working programme. 
 
CURVES 

Here the values are given in order to form a 

curve to be followed by the programme. 
 
RECORD 

Statistic of the last seven days for every one of 

the programmes. 
 
ANOMALIES 

Record of the different anomalies that can take 

place in the installation. 
 
CONFIGURATION 

Here the equipment is configurated to adapt it to 

the necessities of the installation to be controlled. This 
is normally done by the installator. It is important not to 
access this function without an exact knowledge of 
what you are going to modify. 
 
VARIOUS 

To leave the alarm in the stand by position or 

not, set the clock or leave the equipment temporarily in 
stop. 
 

In some screens some letters with inverted 

background will appear and they have got the following 
meaning.   

P= Programme: Programme number. 
C= Curve: Activated curve (1) or deactivated (0) 
E= Input: Value of the sensor/s of input. 
S= Outlet: State of the outlet. 

 

TYPES OF WORKING 

 

We call  types of working to the different ways of 

working the equipment allows. 

TYPE-01 

Input of sensors, outlet by relay. 
When the value of the sensor is lower than the 

value of reference, the outlet is activated until it 
overcomes it and reaches the value of the differential. 

Examples: Heating, Humidification, etc.  

 
TYPE-02 

Input of sensors, outlet by relay. 

 
 

When the value of the sensor is higher than the 

value of reference, the outlet is activated until It 
reaches the value of the differential. 

Examples: Refrigeration, drying, etc. 

 
TYPE-03 

Timetable programme, outlet by relay. 

 

When the day and time programme are 

reached, the outlet is activated, finishing when there is 
no more time of activation left. Up to 99 periodical 
activations can even be programmed, at the same 
time. The programme can also be started obeying any 
other programme. 
        Example: Lighting, feeding, irrigation, 
humidification by time, when the humidity of a certain 
value decreases, etc. 
 
TYPE-04 

Input of sensors, analogical outlet (0-10 V). 
Every programme is given a reference, a 

proportional band and a maximum and minimum 
percentage of outlet. When the value of the sensor is 
lower than the reference, the outlet increases 
proportionally from the minimum to the maximum, 
obtaining this last one when the sensor reaches the 
value of reference minus the programmed proportional 
band. 

Example: Proportional heating. 

 

 

TYPE –05 

Input of sensors, analogical outlet (0-10 V) 

 

The programme is given a reference, a 

proportional band and a maximum and minimum 
percentage of outlet. When the value of the sensor is 
higher  than the reference, the outlet increases 
proportionally from the minimum to the maximum, 
obtaining this last one when the sensor reaches the 
value of reference plus the programmed proportional 
band. 

Example: Forced ventilation. 

 
 
TYPE-06 

Input of sensors,  outlet by two relays (open  - 

close). 
 

Special type to work on windows with lathe so 

that the natural ventilation can be made. When the 
temperature is higher than the reference, some timings 
are made, one of stop and another of opening. The 
same happens to  close, when the temperature is lower 
than the reference minus the differential. 
 
TYPE-07 

Содержание AMBITROL 100

Страница 1: ...atic premises such as farms greenhouses drying sheds cold rooms etc with 8 analogical inputs for sensors and 2 digital ones to condition working plus 8 analogical outlets of relay all nothing expandab...

Страница 2: ...is work has to be done by an installator The USE is the chapter addressed to the user as it contains all the instructions about the programation and the follow up The equipment has and illuminated alp...

Страница 3: ...ut of sensors outlet by relay When the value of the sensor is higher than the value of reference the outlet is activated until It reaches the value of the differential Examples Refrigeration drying et...

Страница 4: ...modulation of the time of proportional activation to the changes of the sensors The programme is given a reference a proportional band and a maximum and minimum percentage of outlet When the value of...

Страница 5: ...rth terminal bar with a section equal to the supply cables of the switchboard The equipment is protected in the supply by a varistor between the phase and t he neutral which will short circuit the fus...

Страница 6: ...eened cable What is more this cable must never be installed by the power lines The screen of the cable will be connected to the earth terminal by one of its ends If there is not an earth terminal it w...

Страница 7: ...12 0 Num of input 8 Tare 03 5 HR 76 3 To modify the value of the tare we have to calculate the error of the reading of the sensor and add or deduct it to the value of the tare Example Tare 03 5 HR 76...

Страница 8: ...and outlets before as they are related to the programme First we can see the following screen asking for the number of PROGRAMME we want to access give the number and ENTER The equipment has capacity...

Страница 9: ...the two existing digital inputs to connect securities external to the equipment if they are not used to count For the input 1 enter the code 81 and for the input 2 the code 82 in the blank for the con...

Страница 10: ...differential of working This is done in the types of o utlet by relay types 1 2 6 except type 3 7 8 and 9 P02 VENT 1 C1pos 018 Differential 00 5 C This value is added or deducted according to the typ...

Страница 11: ...and the second one will not stop until it has finished all the programme The programmes with analogical outlet or of proportional action are started when the outlet is over 60 and stop when it decreas...

Страница 12: ...used by the programmes in order to do a variable and automatic control Here we can see a simple example P02 HEAT 1 C1 Point1 Pos 003 Ref 29 8 C Pos 008 Ref 27 5 C Pos 020 Ref 25 0 C Pos 045 Ref 20 0...

Страница 13: ...ased The configuration the programmes and the curves are not erased Without battery E y n 27 03 Alarm in programme Any programme to which we have given values in high or low alarm and the value of the...

Страница 14: ...changes in the timing programmes type 3 as no value of sensor is indicated but we indicate the value of time that is left to finish the working If it is in hours and minutes the format is 00 00 if it...

Страница 15: ...S Stop PROGRAMME P06 HUMI 4 C0 Reference 75 0 HR Differential 03 0 HR High alarm 00 0 Low alarm 00 0 Manual Yes no No CURVE 1 P06 HUMI 4 C1Pto1 Pos 000 Ref 00 0 HR Pos 000 Ref 00 0 HR Pos 000 Ref 00...

Страница 16: ...LUE OF SENSOR 20 0 REFERENCE DIFFERENTIAL 15 0 10 0 Low alarm 5 0 START STOP TYPE 3 Timing programme outlet by relay When the day and time programmed are reached the outlet is activated finishing when...

Страница 17: ...ULT P03 HEAT 1 E 21 5 C S 025 PROGRAMME P03 HEAT 1 C0 Reference 22 0 C Pro Band 02 0 C Min 00 Max 090 High alarm 00 0 Low alarm 03 8 Manual Yes no No CURVE1 P03 HEAT 1 C1Pto1 Pos 000 Ref 34 0 C Pos 01...

Страница 18: ...1 Num of inputs 1 4 Num of outlet 02 Conditioning Pro 00 Affects in code 00 RECORD VENT 1 21 06 083 24 9 23 4 22 4 C In the inputs of the powermeter of retromessage of window the maximum and minimum v...

Страница 19: ...ifferential CONSULT P01 VTNA 0 E 24 8 C S Open PROGRAMME P01 VTNA 0 C0 Reference 24 0 C Differential 02 0 C Tim Open 05 s Pause Open 128 s Tim Close 100 s Pause Close 100s Manual Yes no No CURVE1 P01...

Страница 20: ...the percentage of the cycle of modulation and the rest of the proportion will not be activated This will be repeated once the time of the cycle of modulation is finished Example proportional heating...

Страница 21: ...e percentage of the cycle of modulation a nd the rest of the proportion will not be activated This will be repeated once the time of the cycle of modulation is finished Example proportional ventilatio...

Страница 22: ...ensors CONSULT P05 VENT 1 E 25 1 C S 055 PROGRAMME P05 VENT 1 C0 Reference 24 0 C Pro Band 02 0 C Min 00 Max 100 High alarm 00 0 Low alarm 03 5 Manual Yes no No CURVE1 P05 VENT 1 C1Pto1 Pos 000 Ref 29...

Страница 23: ...s distributed proportionally to the percentage required by every programme The types of working 7 and 8 can only use a sensor input the other types can do the average of two of them If the humidificat...

Страница 24: ...24...

Отзывы: