32
Pro-7s/1200
Pro-7s/2400
Guide numbers in metres/feet at 100 ASA
with a Magnum 50° Reflector
140
201
Flash Duration (t 0.5) at:
Pro-7 head
Pro-7 twin
Pro-7 head
Pro-7 twin
4800 Ws
–
–
–
1/1600 sec.
2400 Ws
–
1/2200 sec.
1/1600 sec.
1/2200
1200 Ws
1/2200 sec.
1/3200
1/2200
1/3200
600 Ws
1/3200
1/5300
1/2700
1/4500
300
Ws
1/4500 1/6800 1/3200 1/5300
150
Ws
1/5300
1/8000 1/5300 1/8000
75 Ws
1/8000
1/12000
1/5300
1/8000
37,5 Ws
1/8000
1/12000
1/8000
–
18.75 Ws
1/12000
–
–
–
PLEASE NOTE: With Pro-7 twin and two Pro-7s generators the recharging time is approx. twice as fast.
Recharging Time at:
230V/50Hz
0.08 - 0.8 sec.
0.12 - 1.5 sec
120V/60Hz
0.10 - 0.9
0.14 - 1.6
200V/50Hz
0.08 - 1.1
0.12 - 2.1
100V/50Hz
0.14 - 1.6
0.18 - 2.9
Power Consumption (Turbo)
200 - 240V, 50/60Hz
10 A (fuse)/generator
100 - 120V, 50/60Hz
15 A (fuse)/generator
Maximum Modelling Light
Maximum 500 W per head or totally 1500 W when three heads are used. Please note that the
modelling light output automatically adjusts itself to the voltage in question (100 - 240V).
Size & weight, generators
Pro-7s/1200
Pro-7s/2400
Width x length x height cm/in
24 x 17 x32
24 x 17 x 40
9
1
/
2
x 6
3
/
4
x12
9
1
/
2
x 6
3
/
4
x 15
3
/
4
Weight, kg/lb
9 / 20
12 / 26
Size weight, lamp head
Length (incl. glass
26 x 10 cm
cover) x diameter, cm/in
10” x 4”
Weight, kg/lb
2.4 / 5
Gas Generator
Most gas generators with an output of 3000 W or more can always power Profoto generators.
Please note that you always need a ProGas unit between the gas generator and the Profoto gen-
erator in order not to damage these two units (only 230V). For more information please contact
your local dealer.
Technical Data Pro-7s
Содержание Pro-7 ring