Modeling light setting

1.  Use the Model Button [10a] to select the modeling light:

a.  To select proportional modeling light, press and hold down the Model Button [10a] 

until the PROP Indicator [10b] is illuminated.

b.  To select free modeling light, press and hold down the Model Button [10a] until 

the FREE Indicator [10c] is illuminated. The energy level of the latest selected free 
modeling light setting will be activated.

c.  To turn off the modeling light, press the Model Button [10a]. Both the PROP 

Indicator [10b] and the FREE Indicator [10c] will be turned off. Press the Model 
Button [10a] again to turn on the modeling light.

Change the level of the free modeling light:
1.  Verify that free modeling light setting is selected (the FREE Indicator [10c] shall be 

illuminated when the modeling light is turned on).

2.  Press the Model Set Button [11]. The Display [1] will start flashing, showing the current 

energy level of the Free modeling light.

3.  While the Display [1] is flashing, use the Setting Knob [7] to change the energy level:

a.  Turn the Setting Knob [7] clockwise to increase the energy level in 1/10 f-stop 

increments and counter-clockwise to decrease.

b.  Press and hold down the Setting Knob [7] and turn the knob clockwise to increase 

the energy in 1 f-stop increments and counter-clockwise to decrease.

4.  Wait until the Display [1] stops flashing. (The Display [1] will now show the energy level 

of the flash light.)

ready signaling setting

1.  Use the Ready Button [9a] to select the ready signaling:

a.  To select sound signaling, press and hold down the Ready Button [9a] until the 

BEEP Indicator [9b] is illuminated.

b.  To select light signaling, press and hold down the Ready Button [9a] until the DIM 

Indicator [9c] is illuminated.

c.  To  select  both  sound  and  light  signaling,  press  and  hold  down  the  Ready 

Button [9a] until both the BEEP Indicator [9b] and the DIM Indicator [9c] are 
illuminated.

d.  To turn off the ready signaling, press the Ready Button [9a]. Both the BEEP 

Indicator [9b] and the DIM Indicator [9c] will be turned off.  Press the Ready 
Button [9a] again to turn on the ready signaling.

Содержание D1 250

Страница 1: ...D1 1000 Air D1 500 Air D1 250 Air D1 500 D1 250 User s Guide...

Страница 2: ...Profoto D1 2 www profoto com...

Страница 3: ...ty Forthisreasonourflashequipmentiswidelyusedin rentalstudiosandrentalhousesworldwide fromParis London Milan NewYork TokyotoCapeTown Some photographers can tell just from seeing a picture if Profotoeq...

Страница 4: ...siderable time after being turned off Do not touch modeling lamp or flash tube when mounting umbrella metal shaftinitsreflectorhole Disconnectlampheadcablebetweengeneratorandlampheadwhenchanging model...

Страница 5: ...r temperature 12 Reflector 12 Umbrella 12 Operating instructions 13 Stand mounting 13 Mounting of external reflector 13 Umbrella mounting 13 Glass cover mounting 13 Power connection 13 Energy level se...

Страница 6: ...nimal stray light and maximal light output Itisdesignedforusewithsoftboxesandumbrellasandforusewithorwithoutadditional reflectors Short flash duration gives images a crisp feel and the fast recycling...

Страница 7: ...enumberofD1units with thesamehighperformanceasProfotoAirRemote ProfotoAirUSB TheProfotoAirUSBdeviceisaUSB2 0transceiver whichconnectsyourD1Airunittoyour PCorMacviaawirelessconnection ProfotoAirUSBallo...

Страница 8: ...erSupplyIndicator 4 TestButton 5 ReadyIndicator 6 ChannelSetButton 7 SettingKnob 8 SLAVESETTING 8a SlaveButton 8b RADIOIndicator 8c IRIndicator 9 READYSETTING 9a ReadyButton 9b BEEPIndicator 9c DIMInd...

Страница 9: ...Profoto D1 9 www profoto com 12 13 14 15 16 17 18 12 SyncConnector 13 PowerSupply AC Connector 14 FuseHolder 15 UmbrellaTube ontheupperside 16 LockingKnob 17 ZoomScale 18 StandAdapter...

Страница 10: ...werbeingcharged intotheunit Energycontrol The current energy level of the flash light is shown in the Display 1 in f stop scale The maximalenergy 100 isshownas10 The Setting Knob 7 is used to adjust t...

Страница 11: ...ned DIM Themodelinglightwillbeturnedoffwhentheunitisbeingcharged andturned onagainwhenthechargingiscompleted Thissettingalsodisablesthecontrolpanel sounds BEEP DIM The modeling light will be turned of...

Страница 12: ...tube a recommended color temperature for daylight type film Distinctive color temperatureadjustmentscanbeobtainedbyusingglasscoverswithdifferentcoatings Reflector D1 is equipped with a built in reflec...

Страница 13: ...1 EnsurethattheD1unitisturnedoffandthatthepowercableisnotconnected 2 Iftheunithasbeeninuse waitfiveminutestoallowtheunittobefullydischarged the autodumpfunction 3 Gentlyremovethefrostedglassplate 4 Ca...

Страница 14: ...modelinglight 3 WhiletheDisplay 1 isflashing usetheSettingKnob 7 tochangetheenergylevel a Turn the Setting Knob 7 clockwise to increase the energy level in 1 10 f stop incrementsandcounter clockwiseto...

Страница 15: ...o channel has to be set on the D1 unit and the ProfotoAir deviceortheProfotoStudioAirprogram ForremotecontrolusingProfotoAirRemote thesameradiochannelandgrouphavetobe setontheD1unitandtheProfotoAirdev...

Страница 16: ...e is removed the modeling light will revert to the default settings the modeling light will be turned off andtheenergylevelofthefreemodelinglightwillbesetto10 1 PresstheOnButton 2 toturnoffthepower 2...

Страница 17: ...around the clasp Grasptheflashtubeinthebottomandpullitstraightoutofthesocket When inserting the new flash tube ensure that the trigger connection clasps properlyaroundtheflashtube Lock the flash tube...

Страница 18: ...ted 2 Iftheunithasbeeninuse waitfiveminutestoallowtheunittobefullydischarged the autodumpfunction 3 PullouttheFuseHolder 14 fromtheunitandremovetheoldfuse 4 PushthenewfuseallthewayintotheFuseHolder On...

Страница 19: ...ly After a while whenthetemperaturehasdecreasedsufficiently theunitwillstartrechargingata normalpace Thisautomaticprotectionwillonlyinterfereunderextremeconditions such aswhentheairventsareblocked Dep...

Страница 20: ...durationt0 5min maxpower 1 700 1 1800 1 1000 1 2600 1 1400 1 3700 Recycling230V 0 2 2 0 0 2 0 95 0 2 0 65 Recycling120V 0 2 2 0 0 2 0 95 0 2 0 65 Colortemperature consistency K 30 30 30 Colortemperatu...

Страница 21: ...ee Off Prop Free Synchronizationmodes Synccable IR Air Synccable IR Air Synccable IR Air Measurements Dimensionsmm length diameter 300x130 170includingStandAdapter Dimensionsinch length diameter 11 8x...

Страница 22: ...This page is intentionally left blank...

Страница 23: ...This page is intentionally left blank...

Страница 24: ...ofotoAB P O Box2023 SE 12821Skarpn ck SWEDEN Phone 4684475300 info profoto com www profoto com 344091 1 320 Printed in Sweden Technical data and product information are subject to change without notic...

Отзывы: