AcuteB2 600 AirS
19
www.profoto.com
Technical data
Energy
600 Ws
Input
12 V
Energy Control
Over a seven f-stop range, in 2/10 step adjustments
f-stop at 2 m (ISO 100/21º)
64.2 with Magnum 50º reflector
Recycling time
LiFe battery: 0.08-2.0 s @ full
Pb battery: 0.09-2.5 s @ full
Flash Capacity
No of flashes at different energy settings
Pb
LiFe
Ws:
600
300
150 75
37
18 9
Energy: Max
-1
-2
-3
-4
-5
-6
Flashes: 160 320 600 1200 2000 4000 8000 (Pb)
Flashes: 225 450
900 1800 3600 7200 14400 (LiFe)
Modeling light
65W continuous modeling light (similar to 90W halogen)
Flash Duration (t0.5)
Ws:
600
150
37
Time:
1/1000 1/2700 1/6800
Energy Precision
1/75 f-stop flash-to-flash
Energy Range
Ws:
600
300
150 75
37
18 9
f-stop:
1/1
1/2
1/4
1/8
1/16 1/32 1/64
Ev:
Max
-1
-2
-3
-4
-5
-6
Auto Dumping
Yes
Battery type
LiFe battery: 13.2 V, 5.0 Ah, LiFePo4
Pb battery: 12.0 V, 5.0 Ah, Non-spillable lead/acid
Battery charging time
5 h with Profoto Charger 1A 2.5 h with Profoto Charger 2A
Battery status indicator
LiFe battery: Yes, but because of the discharge characteristics of the
battery, the indicator will remain on max until it suddenly drops when
there is capacity for just a few more flashes.
Pb battery: 1/1, 1/2 and 1/4 indicators
Battery life
LiFe battery: 1 200 charge cycles 80% capacity left
Pb battery: 300 charge cycles 80% capacity left