background image

Acute2 twin

12

The Acute2 twin is used to obtain even shorter flash duration, 

very quick recycling or to fire 4800 Ws out of one single head. 

An Acute2 twin has two flash tubes. As the flash duration is 

shorter at low power switch settings, and as only half of the 

desired power is used in each tube, consequently shorter flash 

duration is obtained. 

If you require shorter flash duration and you for example need 

1200 Ws, you connect the Acute2 twin to the B sockets on the 

Acute2 1200 generator and fire 600 Ws from each tube. The 

flash duration is shorter than if a standard Acute2 head is used. 

The flash duration at 1200 Ws with an Acute2 head is 1/560 

while it is only 1/1000 with an Acute2 twin.

If, on the contrary, you require faster recycling, you power the 

Acute2 twin with 2 Acute2 generators. The recycling is faster 

since each generator need to recharge less energy. 

To get 4800 Ws from one head you connect the Acute2 twin to 

two Acute2 2400 generators. 

Flash duration and recycling for an Acute2 twin at a certain 

power setting - for example 1200 Ws - compares with a Acute2 

head powered with 600 Ws.

Since the modelling light is powered from the mains 

supply it is important to check that the rated voltage for 

the modelling lamp corresponds with the mains supply.

The modelling light is a 500W Halogen with a Mini-can socket 

(E11). The flash tube has two metal pins. When removing a 

flash tube, pull it straight out of the sockets. When inserting 

a new flash tube, check that the trigger wire clasps properly 

around the flash tube (please see mounting instructions in 

package).

10 15 18     Glass Cover, frosted, UV-coated (standard)

10 15 19     Glass Cover, frosted, extra UV-coated, -300 gr K

10 15 20     Glass Cover, frosted, uncoated

10 15 21     Glass Cover, clear, UV-coated

10 20 07     500W, 120V, Halogen, Mini-can

10 20 15     500W, 240V, Halogen, Mini-can

Содержание Acute2 1200

Страница 1: ...Acute2 manual Profoto Stockholm Sweden...

Страница 2: ...tion Do not connect flash heads with the protectivecapinplace When using the flash do not place filters diffusing mater ials or any other obstructions directly onto the glass cover flash tube or model...

Страница 3: ...Brief instructions 15 Energy distribution 17 Energy distribution Acute2 twin 20 Energy control 21 Gas generator 24 Troubleshooting guide 26 Technical data 27 The Acute2 system consists of the followi...

Страница 4: ...cute2 heads in particular offer you this possibility The light source both the flash tube and the modelling light is placed high and free in the flash head This makes it easier for you to adjust the l...

Страница 5: ...e a painter s brush an artist s chisel or a musician s instrument their form and design should reflecttheirfunction theyshouldhavetherightfeel and they should be aesthetically pleasing Profotos founde...

Страница 6: ...d ProZoom Pattern Holder Pin Set Iris Diaphragm Heat absorbing filter Slide holders 60x60 24x36 ProFocus ProBox White Transparent Silver 5 and 7 foot Reflector Glass Kit ProGlobe w Chimera Barn Doors...

Страница 7: ...h is the base of the Profoto line of products The lines indicate the possible combinations that Profoto equipment offers ProGas Zoom Reflector 7 Grid Reflector 7 Grid FilterHolder 40x40 cm Filter Cass...

Страница 8: ...ash tube 2 Umbrella holder 3 Manoeuvre system with locking lever 4 Stand adapter 16mm 5 8 5 Acute2 Glass Cover frosted UV coated 6 Halogen modelling lamp 250W Mini can E11 socket 7 Locking springs 8 Z...

Страница 9: ...h tubes 2 Umbrella holder 3 Manoeuvre system with locking lever 4 Stand adapter 16mm 5 8 5 PB Twin Glass Cover frosted UV coated 6 Halogen modelling lamp 500W Mini can E11 socket 7 Locking springs 8 M...

Страница 10: ...rofoto reflec tors and accessories fit the Acute2 heads A UV reduced quartz flash tube is included with all Acute2 heads The flash tube has two metal pins When removing a flash tube pull it straight o...

Страница 11: ...UV reducing quartz flash tube the frost ed glass cover offers the recommended colour temperature fordaylighttypefilm Distinctivecolourtemperatureadjust mentscanbeobtainedbycombiningglasscoverswithdif...

Страница 12: ...s faster since each generator need to recharge less energy To get 4800 Ws from one head you connect the Acute2 twin to two Acute2 2400 generators Flash duration and recycling for an Acute2 twin at a c...

Страница 13: ...reases the light source thereby producing a soft light with little shadow For close ups there is a reflector that focuses the light 50 cm in front of the camera lens The maximum charge is 9600 Ws minu...

Страница 14: ...ntrol Max Dim Off 5 Ready Lamp Test Button 6 Fast Slow Recharging and Amp draw Button 7 Voltage Selector Mains Supply 8 Mains Frequency Selector 9 Sound Switch 10 Slave Photocell Switch On Off 11 Phot...

Страница 15: ...veselectedongenerator correspondswiththemainssupplyvoltage Check that the modelling lamp has the correct voltage Connect flash head s Connect the mains supply cable Choose recycling time Switch on the...

Страница 16: ...at Contact your Profoto distributor for proper equipment Connecting lamp heads One twoorthreelampheadscanbeconnectedtothesockets marked A B and B 15 When connecting the lamp plug align the white dots...

Страница 17: ...energy in group A is controlled by the A switch 12 and the energy in group B is controlled by the B switch 14 In each group the energy can be halved or quartered Please see panel for details Below yo...

Страница 18: ...the energy one f stop by switching A B A B switch to positionA B 3 Further reduce the energy one or two f stops by halving or quartering the energy with the B switch 4 Use the dial BRACKET for fine a...

Страница 19: ...eadjustmentsandtofurther reducetheenergybytwof stops Asymmetricallightdistribution 1 Connectoneheadtoeachsocket 2 SettheA B A BswitchinpositionA B Theenergy for thetwogroupsisnowindividuallycontrolled...

Страница 20: ...h 4 Use the dial BRACKET for fine adjustments and to further reduce the energy by two f stops Two generators 1 Connect the head socket to socket A on each generator 2 Reduce the energy one f stop by s...

Страница 21: ...ative exposures bracketing 1 Turn the dial to 1 Find your correct f stop with your flash meter Make the first exposure 2 Turn the dial to max The power increases to an overexposure of one f stop Make...

Страница 22: ...he BRACKET dial set to 1 1 the A B A B switch to the A B position and the B switch set at 1 4 Photo Cell The built in photo cell 11 will sense flash release as well as IR signals from most IR transmit...

Страница 23: ...ortional mod light To dim the dim light use the Mod A 2 dial to control the head connected to group A 17 and the Mod B 3 dial for the head s connected to group B 19 20 Automatic Safety Function If the...

Страница 24: ...least 2000W continuous output power for each connected unit Always check this figure against the data sheet as the model number does not always reflect the true power output NOTE Generators less power...

Страница 25: ...rds required of professional equipment by professional photographers The R test is a rigorous performance test that Profoto generators are put through 360 full power flashes are released during one ho...

Страница 26: ...19x22cm 5 1x7 5x8 7in incl Handle Weight 2400Ws 5 9kg 12 9 lb 1200Ws 4 1kg 9 0 lb Max Modelling lamp 500W and 1000W per generator Problem No ready lamp but ready sound No flash Fuses keep blowing Cont...

Страница 27: ...0 250 VAC 50 or 60 Hz 10 Amps recommended for 2 units Gasoline generators see guidelines on page 24 minimum 2000W true output per flash unit Charge speed set at Max Flash duration t0 5 one head t0 5 1...

Страница 28: ...x 46 0 8 447 53 20 www profoto com info profoto se Posh Produktion www posh se Photos by Jan Fridlund Articleno 33 40 06 Product codes descriptions and included components may vary from market to mark...